Quantitative evaluation method of noise texture for iteratively reconstructed x-ray CT images

被引:4
|
作者
Lauzier, Pascal Theriault [1 ]
Tang, Jie [1 ]
Chen, Guang-Hong [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53704 USA
关键词
image texture analysis; computed tomography; iterative reconstruction algorithms; non-linear regularization; POWER SPECTRUM; TOMOGRAPHY; ALGORITHMS; CANCER;
D O I
10.1117/12.878408
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Recently, iterative image reconstruction algorithms have been extensively studied in x-ray CT in order to produce images with lower noise variance and high spatial resolution. However, the images thus reconstructed often have unnatural image noise textures, the potential impact of which on diagnostic accuracy is still unknown. This is particularly pronounced in total-variation-minimization-based image reconstruction, where the noise background often manifests itself as patchy artifacts. In this paper, a quantitative noise texture evaluation metric is introduced to evaluate the deviation of the noise histogram from that of images reconstructed using filtered backprojection. The proposed texture similarity metric is tested using TV-based compressive sampling algorithm (CSTV). It was demonstrated that the metric is sensitive to changes in the noise histogram independent of changes in noise level. The results demonstrate the existence tradeoff between the texture similarity metric and the noise level for the CSTV algorithm, which suggests a potential optimal amount of regularization. The same noise texture quantification method can also be utilized to evaluate the performance of other iterative image reconstruction algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A method for quantitative evaluation of a valgus knee orthosis using biplane x-ray images
    Zeighami, Ali
    Dumas, Raphael
    Bleau, Jacinthe
    Lavoie, Frederic
    de Guise, Jacques
    Aissaoui, Rachid
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4815 - 4818
  • [2] The study on quantitative assessment of osteoporosis based on texture analysis of X-ray images
    Yang, XH
    Zhang, DF
    Jiang, DZ
    IEEE-EMBS ASIA PACIFIC CONFERENCE ON BIOMEDICAL ENGINEERING - PROCEEDINGS, PTS 1 & 2, 2000, : 221 - 223
  • [3] Cardiac motion correction based on partial angle reconstructed images in x-ray CT
    Kim, Seungeon
    Chang, Yongjin
    Ra, Jong Beom
    MEDICAL PHYSICS, 2015, 42 (05) : 2560 - 2571
  • [4] Noise simulation in x-ray CT
    Massoumzadeh, P
    Earl, OA
    Whiting, BR
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 898 - 909
  • [5] A quantitative evaluation of the hip prosthesis segmentation quality in X-ray images
    Oprea, Alina
    Vertan, Constantin
    ISSCS 2007: INTERNATIONAL SYMPOSIUM ON SIGNALS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 2007, : 197 - +
  • [6] QUANTITATIVE TEXTURE EVALUATION ON THE BASIS OF X-RAY AND NEUTRON-DIFFRACTION ANALYSIS
    TRUSZKOWSKI, W
    POSPIECH, J
    MUCKLICH, A
    MEMOIRES SCIENTIFIQUES DE LA REVUE DE METALLURGIE, 1979, 76 (03): : 159 - 164
  • [7] STUDY OF TEXTURE OF LOW-CARBON STEEL BY QUANTITATIVE X-RAY METHOD
    BOCHKOV, NG
    SPEVAK, EY
    PARFENOV, GV
    FIZIKA METALLOV I METALLOVEDENIE, 1972, 34 (06): : 1288 - 1291
  • [8] An Analytical Method for Reducing Metal Artifacts in X-Ray CT Images
    Chen, Ming
    Xia, Dimeng
    Wang, Dan
    Han, Jingqi
    Liu, Zhu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2019, 2019
  • [9] A simple method for automated lung segmentation in X-ray CT images
    Zheng, B
    Leader, JK
    Maitz, GS
    Chapman, BE
    Fuhrman, CR
    Rogers, RM
    Sciurba, FC
    Perez, A
    Thompson, P
    Good, WF
    Gur, D
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1455 - 1463
  • [10] STREAK REMOVAL METHOD FOR CT BASED DIGITAL X-RAY IMAGES
    MARGOSIAN, PM
    COMPUTER GRAPHICS AND IMAGE PROCESSING, 1982, 19 (01): : 76 - 80