Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

被引:16
|
作者
Schultze, V. [1 ]
Scholtes, T. [1 ]
IJsselsteijn, R. [1 ,2 ]
Meyer, H. -G. [1 ]
机构
[1] Leibniz Inst Photon Technol, D-07745 Jena, Germany
[2] Supracon AG, D-07751 Jena, Germany
关键词
NOISE; VAPOR;
D O I
10.1364/JOSAB.32.000730
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F = 4 pumping: F = 3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F = 3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the M-x and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the M-x mode it is more pronounced (about 50 versus 200 fT/root Hz for a 50 mm(3) Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed. (C) 2015 Optical Society of America
引用
收藏
页码:730 / 736
页数:7
相关论文
共 50 条
  • [1] Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam
    Zhang Lu-Lu
    Bai Le-Le
    Yang Yu-Lin
    Yang Yong-Biao
    Wang Yan-Hua
    Wen Xin
    He Jun
    Wang Jun-Min
    ACTA PHYSICA SINICA, 2021, 70 (23)
  • [2] Sensitivity studies and optimization of arrangements of optically pumped magnetometers in simulated magnetoencephalography
    Eichardt, Roland
    Strohmeier, Daniel
    Hunold, Alexander
    Machts, Rene
    Haueisen, Jens
    Oelsner, Gregor
    Schmidt, Christian B.
    Schultze, Volkmar
    Stolz, Ronny
    Graichen, Uwe
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 38 (03) : 953 - 964
  • [3] Microfabricated Optically-Pumped Magnetometers
    Knappe, Svenja
    2014 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2014,
  • [4] Floquet description of optically pumped magnetometers
    Florez, Hans Marin
    Pyragius, Tadas
    PHYSICAL REVIEW A, 2021, 103 (03)
  • [5] Recent progress in optically pumped magnetometers
    Alexandrov, EB
    PHYSICA SCRIPTA, 2003, T105 : 27 - 30
  • [6] VCSEL frequency stabilization for optically pumped magnetometers
    闫业广
    刘刚
    林海笑
    尹凯峰
    王锟
    陆吉玺
    Chinese Optics Letters, 2021, 19 (12) : 69 - 74
  • [7] VCSEL frequency stabilization for optically pumped magnetometers
    Yan, Yeguang
    Liu, Gang
    Lin, Haixiao
    Yin, Kaifeng
    Wang, Kun
    Lu, Jixi
    CHINESE OPTICS LETTERS, 2021, 19 (12)
  • [8] Peripheral Nerve Magnetoneurography With Optically Pumped Magnetometers
    Bu, Yifeng
    Prince, Jacob
    Mojtahed, Hamed
    Kimball, Donald
    Shah, Vishal
    Coleman, Todd
    Sarkar, Mahasweta
    Rao, Ramesh
    Huang, Mingxiong
    Schwindt, Peter
    Borna, Amir
    Lerman, Imanuel
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [9] Concurrent spinal and brain imaging with optically pumped magnetometers
    Mardell, Lydia C.
    Spedden, Meaghan E.
    O'Neill, George C.
    Tierney, Tim M.
    Timms, Ryan C.
    Zich, Catharina
    Barnes, Gareth R.
    Bestmann, Sven
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 406
  • [10] Discrimination of finger movements by magnetomyography with optically pumped magnetometers
    Greco, Antonino
    Baek, Sangyeob
    Middelmann, Thomas
    Mehring, Carsten
    Braun, Christoph
    Marquetand, Justus
    Siegel, Markus
    SCIENTIFIC REPORTS, 2023, 13 (01):