Precision of glomerular filtration rate determinations for long-term slope calculations is improved by simultaneous infusion of I-125-iothalamate and I-131-hippuran

被引:0
|
作者
Apperloo, AJ
deZeeuw, D
Donker, AJM
deJong, PE
机构
[1] UNIV GRONINGEN HOSP, DEPT MED, DIV NEPHROL, 9713 EZ GRONINGEN, NETHERLANDS
[2] FREE UNIV AMSTERDAM, DEPT MED, AMSTERDAM, NETHERLANDS
来源
关键词
GFR; effective renal plasma flow; renal function; end-stage renal failure; clearance techniques;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In studies on the progression of chronic renal failure the measurement of GFR must be very reliable, Sequential determination of GFR using the renal clearances of exogenous tracers such as inulin or iothalamate is the most accepted method, However, because of inaccuracies in urine collection, intratest variation, and thus intertest variation, of these clearances is considerable, This has a negative impact on the precision of long-term slope estimations, A previously described method of GFR determination on the basis of simultaneous infusion of I-131-hippuran and I-125-iothalamate corrects for inaccurate urine collection. To study whether this correction method improves the precision of the GFR slope measurement, this study analyzed longitudinal GFR data obtained in 71 patients with renal disease during a follow-up of 84 to 180 wk (477 renal function studies). All GFR were calculated by using both the standard renal clearance method and the correction method. The intratest and intertest coefficient of variation was significantly smaller for the correction method compared with the standard method (1.93 +/- 0.20 versus 8.48 +/- 1.66%, P < 0.0005; and 2.88 +/- 0.32 versus 5.12 +/- 0.66%, P < 0.005, respectively). As a result, the precision of the GFR slope estimation was significantly better with the correction method compared with the standard method (error of the slope, 1.63 +/- 1.09 versus 2.35 +/- 2.36 mL/min per yr, P < 0.01), This improvement in precision of the slope by using the correction method reduces the necessary sample size needed to detect a GFR slope difference between interventions to about 30% of that needed when using the standard method, It is concluded that the precision of GFR measurements is improved by using correction for inaccurate urine collection with concomitant I-131-hippuran clearance.
引用
收藏
页码:567 / 572
页数:6
相关论文
共 11 条
  • [1] SIMULTANEOUS MEASUREMENT OF GLOMERULAR AND TUBULAR CLEARANCES BY CONTINUOUS RADIOISOTOPIC INFUSION (IOTHALAMATE I-125, HIPPURAN I-131)
    MIROUZE, J
    MONNIER, L
    OLIVIER, C
    UNION MEDICALE DU CANADA, 1973, 102 (05): : 1120 - 1124
  • [2] Glomerular filtration rate measurements by 125I-iothalamate should be corrected for inaccurate urine collections with 131I-hippuran
    Michels, W. M.
    Grootendorst, D. C.
    Rozemeijer, K.
    Dekker, F. W.
    Krediet, R. T.
    CLINICAL NEPHROLOGY, 2009, 72 (05) : 337 - 343
  • [3] GLOMERULAR FILTRATION-RATE MEASUREMENT AND I-131-HIPPURAN RENOGRAPHY BEFORE UNILATERAL NEPHRECTOMY
    MOGENSEN, P
    ROSSING, N
    GIESE, J
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1972, 6 (03): : 228 - 231
  • [4] Simultaneous measurement of extracellular volume and glomerular filtration rate with the constant infusion method using 125I-Iothalamate.
    Visser, FW
    Kocks, MJ
    de Hooge, MN
    Jager, PL
    Muntinga, JH
    Navis, GJ
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 522A - 522A
  • [5] MEASUREMENT OF GLOMERULAR FILTRATION RATE AND EFFECTIVE RENAL PLASMA FLOW IN MAN BY IOTHALAMATE 125I AND IODOPYRACET 131I
    ELWOOD, CM
    SIGMAN, EM
    CIRCULATION, 1967, 36 (03) : 441 - &
  • [6] SIMULTANEOUS MEASUREMENT OF GLOMERULAR FILTRATION RATE AND EFFECTIVE RENAL PLASMA FLOW WITH 57CO-CYANOCOBALAMIN AND 125I-HIPPURAN
    CUTLER, RE
    GLATTE, H
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1965, 65 (06): : 1041 - &
  • [7] DETERMINATION OF SIMULTANEOUS EFFECTIVE RENAL PLASMA FLOW AND GLOMERULAR FILTRATION RATE WITH 131I-ORTHO-IODOHIPPURATE AND 125I-ALLYL INULIN
    SUMMERS, RE
    CONCANNO.JP
    WEIL, C
    COLE, C
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1967, 69 (06): : 919 - &
  • [8] QUANTITATIVE LONG-TERM DETERMINATIONS OF ALVEOLAR BONE-MINERAL MASS IN MAN BY I125 ABSORPTIOMETRY .1. ACCURACY AND PRECISION OF METHOD
    HENRIKSON, CO
    BERGSTROM, J
    ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1974, 13 (05): : 377 - 392
  • [9] Improved long-term survival for unresectable hepatocellular carcinoma (HCC) with a combination of surgery and intrahepatic arterial infusion of 131I-anti-HCC mAb. Phase I/II clinical trials
    Zhao-Chong Zeng
    Zhao-You Tang
    Kang-Da Liu
    Ji-Zhen Lu
    Hong Xie
    Zhen Yao
    Journal of Cancer Research and Clinical Oncology, 1998, 124 : 275 - 280
  • [10] Improved long-term survival for unresectable hepatocellular carcinoma (HCC) with a combination of surgery and intrahepatic arterial infusion of 131I-anti-HCC mAb.: Phase I/II clinical trials
    Zeng, ZC
    Tang, ZY
    Liu, KD
    Lu, JZ
    Xie, H
    Yao, Z
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 1998, 124 (05) : 275 - 280