Performance of a hard X-ray split-and-delay optical system with a wavefront division

被引:23
|
作者
Hirano, Takashi [1 ]
Osaka, Taito [1 ,2 ]
Morioka, Yuki [1 ]
Sano, Yasuhisa [1 ]
Inubushi, Yuichi [2 ,3 ]
Togashi, Tadashi [2 ,3 ]
Inoue, Ichiro [2 ]
Matsuyama, Satoshi [1 ]
Tono, Kensuke [2 ,3 ]
Robert, Aymeric [4 ]
Hastings, Jerome B. [5 ]
Yamauchi, Kazuto [1 ]
Yabashi, Makina [2 ]
机构
[1] Osaka Univ, Grad Sch Engn, Dept Precis Sci & Technol, 2-1 Yamada Oka, Suita, Osaka 5650871, Japan
[2] RIKEN SPring 8 Ctr, 1-1-1 Kouto, Sayo, Hyogo 6795148, Japan
[3] Japan Synchrotron Radiat Res Inst JASRI, 1-1-1 Kouto, Sayo, Hyogo 6795198, Japan
[4] SLAC Natl Accelerator Lab, Linac Coherent Light Source, 2575 Sand Hill Rd, Menlo Pk, CA 94025 USA
[5] SLAC Natl Accelerator Lab, 2575 Sand Hill Rd, Menlo Pk, CA 94025 USA
来源
关键词
hard X-ray free-electron laser; split-and-delay optics; multi-crystal optics; X-ray photon correlation spectroscopy; FREE-ELECTRON LASER; SCATTERING; DYNAMICS; UNIT; LINE;
D O I
10.1107/S1600577517014023
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performance of a hard X-ray split-and-delay optical (SDO) system with a wavefront division scheme was investigated at the hard X-ray free-electron laser facility SACLA. For the wavefront division, beam splitters made of edgepolished perfect Si(220) crystals were employed. We characterized the beam properties of the SDO system, and investigated its capabilities for beam manipulation and diagnostics. First, it was confirmed that shot-to-shot noninvasive diagnostics of pulse energies for both branches in the SDO system was feasible. Second, nearly ideal and identical focal profiles for both branches were obtained with a spot size of similar to 1.5 mu m in full width at half-maximum. Third, a spatial overlap of the two focused beams with a sub-mu m accuracy was achieved by fine tuning of the SDO system. Finally, a reliable tunability of the delay time between two pulses was confirmed. The time interval was measured with an X-ray streak camera by changing the path length of the variable-delay branch. Errors from the fitted line were evaluated to be as small as +/- 0.4 ps over a time range of 60 ps.
引用
收藏
页码:20 / 25
页数:6
相关论文
共 50 条
  • [1] Wavelength-tunable split-and-delay optical system for hard X-ray free-electron lasers
    Osaka, Taito
    Hirano, Takashi
    Sano, Yasuhisa
    Inubushi, Yuichi
    Matsuyama, Satoshi
    Tono, Kensuke
    Ishikawa, Tetsuya
    Yamauchi, Kazuto
    Yabashi, Makina
    OPTICS EXPRESS, 2016, 24 (09): : 9187 - 9201
  • [2] Hard x-ray - optical four-wave mixing using a split-and-delay line
    Peters, William K.
    Feltman, Jacob
    Jones, Travis
    Song, Sanghoon
    Chollet, Matthieu
    Robinson, Joseph
    Padmanabhan, Prashant
    Foglia, Laura
    Bencivenga, Filippo
    Coffee, Ryan
    Bowlan, Pamela
    OPTICS EXPRESS, 2023, 31 (19) : 31410 - 31418
  • [3] A hard x-ray split-and-delay unit for the HED Instrument at the European XFEL
    Roling, Sebastian
    Kaercher, Victor
    Samoylova, Liubov
    Appel, Karen
    Braun, Stefan
    Gawlitza, Peter
    Siewert, Frank
    Zastrau, Ulf
    Rollnik, Matthias
    Wahlert, Frank
    Zacharias, Helmut
    ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION IV, 2017, 10237
  • [4] A hard x-ray split-and-delay unit for the HED experiment at the European XFEL
    Roling, Sebastian
    Appel, Karen
    Braun, Stefan
    Buzmakov, Alexey
    Chubar, O.
    Gawlitza, Peter
    Samoylova, Liubov
    Siemer, Bjoern
    Schneidmiller, Evgeny
    Sinn, Harald
    Siewert, Frank
    Tschentscher, Thomas
    Wahlert, Frank
    Woestmann, Michael
    Yurkov, Mikhail
    Zacharias, Helmut
    X-RAY FREE-ELECTRON LASERS: BEAM DIAGNOSTICS, BEAMLINE INSTRUMENTATION, AND APPLICATIONS II, 2014, 9210
  • [5] A soft x-ray split-and-delay unit for FLASH II
    Roling, Sebastian
    Rollnik, Matthias
    Kuhlmann, Marion
    Ploenjes, Elke
    Wahlert, Frank
    Zacharias, Helmut
    ADVANCES IN X-RAY FREE-ELECTRON LASERS INSTRUMENTATION IV, 2017, 10237
  • [6] Split-Delay Optical System for Hard X-Ray Free-Electron Lasers
    Wu Chen
    Zhang Zhiyuan
    Xu Yihui
    Song Li
    Dong Xiaohao
    Liu Zhi
    LASER & OPTOELECTRONICS PROGRESS, 2023, 60 (01)
  • [7] Development of a hard X-ray split-and-delay line and performance simulations for two-color pump-probe experiments at the European XFEL
    Lu, W.
    Friedrich, B.
    Noll, T.
    Zhou, K.
    Hallmann, J.
    Ansaldi, G.
    Roth, T.
    Serkez, S.
    Geloni, G.
    Madsen, A.
    Eisebitt, S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (06):
  • [8] Compact hard X-ray split-and-delay line for studying ultrafast dynamics at free-electron laser sources
    Rysov, Rustam
    Roseker, Wojciech
    Walther, Michael
    Gruebel, Gerhard
    JOURNAL OF SYNCHROTRON RADIATION, 2019, 26 : 1052 - 1057
  • [9] X-ray split and delay system for soft x-ray at LCLS
    Castagna, J. C.
    Murphy, B.
    Bozek, J.
    Berrah, N.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [10] Mirror-based soft x-ray split-and-delay system for femtosecond pump-probe experiments at LCLS
    Murphy, Brendan F.
    Castagna, Jean-Charles
    Bozek, John D.
    Berrah, Nora
    X-RAY FREE-ELECTRON LASERS: BEAM DIAGNOSTICS, BEAMLINE INSTRUMENTATION, AND APPLICATIONS, 2012, 8504