VAK-2 eddy current device for evaluating the degree of damage of the metal of pipes of steam superheaters of thermal electric power stations by intercrystalline corrosion
被引:0
|
作者:
Volkov, BI
论文数: 0引用数: 0
h-index: 0
机构:
Uralsk Sci Res Inst Thermal Engn, Chelyabinsk, RussiaUralsk Sci Res Inst Thermal Engn, Chelyabinsk, Russia
Volkov, BI
[1
]
Temryukh, VM
论文数: 0引用数: 0
h-index: 0
机构:
Uralsk Sci Res Inst Thermal Engn, Chelyabinsk, RussiaUralsk Sci Res Inst Thermal Engn, Chelyabinsk, Russia
Temryukh, VM
[1
]
机构:
[1] Uralsk Sci Res Inst Thermal Engn, Chelyabinsk, Russia
The authors examine the relationships of the parameters of an attached eddy current parametric transducer with the presence and the degree of damage of pipes in the heated surface of thermal power stations made of austenitic steel by intercrystalline corrosion on the side of the external (gas) surface. It is shown that it is principally possible to evaluate the thickness of the damaged layer by the eddy current method. The technical characteristics of the developed VAK-2 specialized device and experience with application of the device under the conditions of thermal electric power stations are described.