Stereoscopic Three-dimensional Optic Flow Distortions Caused by Mismatches Between Image Acquisition and Display Parameters

被引:0
|
作者
Hwang, Alex [1 ]
Peli, Eli [1 ]
机构
[1] Harvard Med Sch, Schepens Eye Res Inst, Dept Ophthalmol, Massachusetts Eye & Ear, Boston, MA 02115 USA
关键词
MOTION SICKNESS; ADAPTATION; DISCOMFORT;
D O I
10.2352/J.ImagingSci.Technol.2019.63.6.060412
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
We analyzed the impact of common stereoscopic three-dimensional (S3D) depth distortion on S3D optic flow in virtual reality environments. The depth distortion is introduced by mismatches between the image acquisition and display parameters. The results show that such S3D distortions induce large S3D optic flow distortions and may even induce partial/full optic flow reversal within a certain depth range, depending on the viewer's moving speed and the magnitude of S3D distortion. We hypothesize that the S3D optic flow distortion may be a source of intra-sensory conflict that could be a source of visually induced motion sickness. (C) 2019 Society for Imaging Science and Technology.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Accommodative responses to stereoscopic three-dimensional display
    Inoue, T
    Ohzu, H
    [J]. APPLIED OPTICS, 1997, 36 (19) : 4509 - 4515
  • [2] Three-dimensional displays - Stereoscopic display watches the viewer
    Mortensen, P
    [J]. LASER FOCUS WORLD, 1996, 32 (06): : 60 - +
  • [3] EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
    Lang, Roberto M.
    Badano, Luigi P.
    Tsang, Wendy
    Adams, David H.
    Agricola, Eustachio
    Buck, Thomas
    Faletra, Francesco F.
    Franke, Andreas
    Hung, Judy
    Perez de Isla, Leopoldo
    Kamp, Otto
    Kasprzak, Jaroslaw D.
    Lancellotti, Patrizio
    Marwick, Thomas H.
    McCulloch, Marti L.
    Monaghan, Mark J.
    Nihoyannopoulos, Petros
    Pandian, Natesa G.
    Pellikka, Patricia A.
    Pepi, Mauro
    Roberson, David A.
    Shernan, Stanton K.
    Shirali, Girish S.
    Sugeng, Lissa
    Ten Cate, Folkert J.
    Vannan, Mani A.
    Luis Zamorano, Jose
    Zoghbi, William A.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (01) : 1 - 46
  • [4] EAE/ASE Recommendations for Image Acquisition and Display Using Three-Dimensional Echocardiography
    Lang, Roberto M.
    Badano, Luigi P.
    Tsang, Wendy
    Adams, David H.
    Agricola, Eustachio
    Buck, Thomas
    Faletra, Francesco F.
    Franke, Andreas
    Hung, Judy
    Perez de Isla, Leopoldo
    Kamp, Otto
    Kasprzak, Jaroslaw D.
    Lancellotti, Patrizio
    Marwick, Thomas H.
    McCulloch, Marti L.
    Monaghan, Mark J.
    Nihoyannopoulos, Petros
    Pandian, Natesa G.
    Pellikka, Patricia A.
    Pepi, Mauro
    Roberson, David A.
    Shernan, Stanton K.
    Shirali, Girish S.
    Sugeng, Lissa
    Ten Cate, Folkert J.
    Vannan, Mani A.
    Luis Zamorano, Jose
    Zoghbi, William A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) : 3 - 46
  • [5] Stereoscopic display of a three-dimensional image of the larynx using high-speed helical scanning
    Sakakura, A
    Yamamoto, Y
    Uesugi, Y
    Nakai, K
    Hayashi, I
    Makimoto, K
    Takenaka, H
    Narabayashi, I
    [J]. ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2000, 62 (06): : 290 - 295
  • [6] Three-dimensional floating image system using a two-lens system and a stereoscopic display
    Baasantseren, Ganbat
    Do, Duc Dung
    Kim, Nam
    Lee, Jae Hwan
    [J]. OPTICAL ENGINEERING, 2007, 46 (11)
  • [7] Three-Dimensional stereoscopic display system on the table-top
    Yoon, Ki-Hyuk
    Lee, Hyoung
    Kim, Sung-Kyu
    [J]. THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2012, 2012, 8384
  • [8] Performance Analysis of Stereoscopic Three-Dimensional Projection Display Systems
    Kim, Seung-Cheol
    Kim, Eun-Soo
    [J]. 3D RESEARCH, 2010, 1 (01): : 1 - 16
  • [9] Acquisition and stereoscopic visualization of three-dimensional ultrasonic breast data
    Hernandez, A
    Basset, O
    Dautraix, I
    Magnin, IE
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (04) : 576 - 580
  • [10] Acquisition and stereoscopic visualization of three-dimensional ultrasonic breast data
    CNRS, Villeurbanne, France
    [J]. IEEE Trans Ultrason Ferroelectr Freq Control, 4 (576-580):