Measured sagged voltages caused by identified power system faults

被引:0
|
作者
Heine, P [1 ]
Pohjanheimo, P [1 ]
Lehtonen, M [1 ]
Oikarinen, A [1 ]
机构
[1] Aalto Univ, Dept Elect & Commun Engn, FIN-02015 Espoo, Finland
关键词
power distribution; power distribution protection; power distribution faults; power quality; voltage sag;
D O I
10.1109/ICHQP.2004.1409333
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Results of voltage sag measurements from five identified fault cases are presented in this paper. All the measurements were performed at one 110/20 kV substation on the 20 kV side. One fault was caused by a fallen 110 kV tower and two cases represent fallen trees on a 20 kV medium voltage feeder supplied by the substation in question. Another case concerns a fault, caused by a small animal, that occurred in a neighbouring MV network. The fifth fault case is an example of the most typical fault type, an earth fault in the 20 kV network where the fault itself causes no sagged voltages at low voltage customer locations but the circuit operations pertaining to the fault clearing procedure do. The measurement arrangements are explained and the measurement results of these particular faults are presented. By anlyzing identified faults in this way, understanding of the system performance can be deepened.
引用
收藏
页码:83 / 87
页数:5
相关论文
共 50 条
  • [1] POWER SYSTEM TRANSIENTS CAUSED BY ARCING FAULTS
    CORNICK, KJ
    KO, YM
    PEK, B
    [J]. IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1981, 128 (01) : 18 - 27
  • [2] POWER SYSTEM TRANSIENTS CAUSED BY ARCING FAULTS
    WONG, KP
    NGUYEN, TT
    [J]. IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1982, 129 (03) : 136 - 136
  • [3] Emissions of electromagnetic fields caused by sagged overhead power lines
    Dezelak, Klemen
    Stumberger, Gorazd
    Jakl, Franc
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (03): : 29 - 32
  • [4] POWER SYSTEM TRANSIENTS CAUSED BY AGING FAULTS - REPLY
    CORNICK, KJ
    KO, YM
    PEK, B
    [J]. IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1982, 129 (03) : 136 - 137
  • [5] Voltage sag distributions caused by power system faults
    Heine, P
    Lehtonen, M
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (04) : 1367 - 1373
  • [6] Voltage sag distributions caused by power system faults
    Heine, P
    Lehtonen, M
    [J]. 2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 894 - 894
  • [7] Analysis of measured harmonic currents and voltages contributed by a commercial wind power system
    Kuo-Hua Liu
    Wang, Li
    [J]. 2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 555 - +
  • [8] TRANSIENT RECOVERY VOLTAGES ASSOCIATED WITH POWER SYSTEM, 3-PHASE TRANSFORMER SECONDARY FAULTS
    HARNER, RH
    RODRIGUEZ, J
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, 91 (05): : 1887 - +
  • [9] The influence of the angle among vectors of power under-system voltages on impedance measured by distance protection
    Szubert, Krzysztof
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (04): : 173 - 177
  • [10] Simulation and risk assessment of power system with cascading faults caused by strong wind weather
    Chen, Lizheng
    Li, Changgang
    Xin, Zheng
    Nie, Shurui
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 143