The nucleus double array cochlear implant:: A new concept for the obliterated cochlea

被引:38
|
作者
Lenarz, T
Lesinski-Schiedat, A
Weber, BP
Issing, PR
Frohne, C
Büchner, A
Battmer, RD
Parker, J
von Wallenberg, E
机构
[1] Med Univ Hannover, Dept Otolaryngol, D-30625 Hannover, Germany
[2] Cochlear Ltd, Sydney, NSW, Australia
[3] Cochlear AG, Basel, Switzerland
关键词
double array; obliteration; cochlear implantation;
D O I
10.1097/00129492-200101000-00006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To increase the number of intracochlear electrodes that may be inserted into a totally obliterated cochlea, a special implant has been developed in collaboration with Cochlear Limited. This implant features two separate electrode carriers containing 11 and 10 active electrodes, respectively, as well as a reference electrode located on the receiver-stimulator package. The potential stimulation modes available with this device therefore include monopolar and bipolar stimulation, and stimulation between both arrays. Surgical Technique: A cochleostomy anterior to the round window provides access to the basal turn (both the scala tympani and the scala vestibuli), and new built connective tissue and bone can be removed until the anterior wall of the basal turn is approached. A second cochleostomy is performed at the second turn caudal of the cochleariform process and 2 mm anterior of the oval window after removal of the incus. New tissue should also be removed if necessary. The two electrode carriers are then placed into the scala tympani of the basal and the scala vestibuli of the second turn, respectively. The remaining surgical procedure is identical with that used for cochlear implantation in patients without obliterated cochleas. Patients: In this clinical study, 10 patients aged 32 to 66 years with an obliterated cochlea each received a double array cochlear implant. All patients had total obliteration of the basal turn either on preoperative imaging or during surgery. Intraoperatively, the second turn was not obliterated in only 4 of 10 patients. Postoperatively, a standard audiologic test battery was used to determine auditory improvement over time. Postoperative Results: All patients achieved significantly improved speech understanding when the additional apical electrode array was used, compared with the use of each electrode array independently. No complications occurred. Conclusion: In patients with a totally obliterated cochlea, the number of intracochlear electrodes can be increased by use of the Nucleus double array implant. As a result, patients achieve significantly better auditory results.
引用
收藏
页码:24 / 32
页数:9
相关论文
共 50 条
  • [1] The nucleus double array cochlear implant:: A new concept for the obliterated cochlea.
    Lenarz, T
    Lesinski-Schiedat, A
    Weber, BP
    Frohne, C
    Büchner, A
    Battmer, RD
    Parker, J
    Von Wallenberg, E
    [J]. LARYNGO-RHINO-OTOLOGIE, 1999, 78 (08) : 421 - 428
  • [2] The nucleus double array cochlear implant for obliterated cochleae
    Lenarz, T
    Battmer, RD
    Frohne, C
    Büchner, A
    Parker, J
    [J]. UPDATES IN COCHLEAR IMPLANTATION, 2000, 57 : 354 - 359
  • [3] Cochlear implantation in the obliterated cochlea
    Raut, V
    Toner, JG
    [J]. CLINICAL OTOLARYNGOLOGY, 2002, 27 (03) : 147 - 152
  • [4] Obliterated cochlea in Cogan's syndrome - Implications for cochlear implant surgery
    Aschendorff, A
    Lohnstein, P
    Schipper, J
    Klenzner, T
    [J]. LARYNGO-RHINO-OTOLOGIE, 2004, 83 (12) : 836 - 839
  • [5] Our Experience with Split Electrode Array Implant for Obliterated Cochlea
    Milind V. Kirtane
    Yogesh I. More
    Gauri Mankekar
    Nishita Mohandas
    Rajesh Patadiya
    [J]. Indian Journal of Otolaryngology and Head & Neck Surgery, 2011, 63 : 237 - 242
  • [6] Our Experience with Split Electrode Array Implant for Obliterated Cochlea
    Kirtane, Milind V.
    More, Yogesh I.
    Mankekar, Gauri
    Mohandas, Nishita
    Patadiya, Rajesh
    [J]. INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2011, 63 (03) : 237 - 242
  • [7] A three-array cochlear implant: a new approach for the ossified cochlea
    Richardson, HC
    Beliaeff, M
    Clarke, G
    Hawthorne, M
    [J]. JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1999, 113 (09): : 811 - 814
  • [8] Depth of Cochlear Implant Array Within the Cochlea and Performance Outcome
    Hilly, Ohad
    Smith, Leah
    Hwang, Euna
    Shipp, David
    Symons, Sean
    Nedzelski, Julian M.
    Chen, Joseph M.
    Lin, Vincent Y. W.
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2016, 125 (11): : 886 - 892
  • [9] Influence of the Cochlear Implant Electrode Array Placement on the Current Spread in the Cochlea
    Schaefer, Friederike
    Enke, Joerg
    Boehnke, Frank
    Hemmert, Werner
    Bai, Siwei
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 6145 - 6148
  • [10] NEUROTRANSMITTERS IN THE COCHLEA AND THE COCHLEAR NUCLEUS
    KLINKE, R