The application of a noncontact physiological recording technique, based on the method of laser Doppler vibrometry (LDV), is described. The effectiveness of the LDV method as a physiological recording modality lies in the ability to detect very small movements of the skin, associated with internal mechanophysiological activities. The method is validated for a range of cardiovascular variables, extracted from the contour of the carotid pulse waveform as a function of phase of the respiration cycle. Data were obtained from 32 young healthy participants, while resting and breathing spontaneously. Individual beats were assigned to four segments, corresponding with inspiration and expiration peaks and transitional periods. Measures relating to cardiac and vascular dynamics are shown to agree with the pattern of effects seen in the substantial body of literature based on human and animal experiments, and with selected signals recorded simultaneously with conventional sensors. These effects include changes in heart rate, systolic time intervals, and stroke volume. There was also some evidence for vascular adjustments over the respiration cycle. The effectiveness of custom algorithmic approaches for extracting the key signal features was confirmed. The advantages of the LDV method are discussed in terms of the metrological properties and utility in psychophysiological research. Although used here within a suite of conventional sensors and electrodes, the LDV method can be used on a stand-alone, noncontact basis, with no requirement for skin preparation, and can be used in harsh environments including the MR scanner.
引用
收藏
页码:847 / 867
页数:21
相关论文
共 50 条
  • [1] Noncontact assessment of cardiovascular activity using laser Doppler vibrometry
    Rohrbaugh, JW
    Rice, RR
    Sirevaag, EJ
    Ryan, AH
    PSYCHOPHYSIOLOGY, 2002, 39 : S71 - S71
  • [2] Effects of mental stress on neuromuscular components of tremor: Assessment using noncontact laser Doppler vibrometry
    Rohrbaugh, JW
    Sirevaag, EJ
    Rice, RR
    Ryan, AH
    PSYCHOPHYSIOLOGY, 2001, 38 : S82 - S82
  • [3] Noncontact sensing of the physiological signs of stress and emotion using laser doppler vibrometry
    Rohrbaugh, JW
    Sirevaag, EJ
    Rice, RR
    Ryan, AH
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2002, 45 (1-2) : 29 - 30
  • [4] The physiology of threat: Remote assessment using Laser Doppler Vibrometry
    Rohrbaugh, JW
    Sirevaag, E
    Stern, JA
    Ryan, AH
    Sensors, and Command, Control, Communications, and Intelligence (C31) Technologies for Homeland Security and Homeland Defense IV, Pts 1 and 2, 2005, 5778 : 567 - 571
  • [5] Noncontact inspection of the curing process of cementitious materials by laser doppler vibrometry
    Tragazikis, I. K.
    Kordatou, T. Z.
    Koutrakou, A. N.
    Exarchos, D. A.
    Dalla, P. T.
    Matikas, T. E.
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2020, 2020, 11379
  • [6] Facial Muscle Activity: High-Sensitivity Noncontact Measurement Using Laser Doppler Vibrometry
    Casaccia, Sara
    Sirevaag, Erik J.
    Frank, Mark G.
    O'Sullivan, Joseph A.
    Scalise, Lorenzo
    Rohrbaugh, John W.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [7] Structural damage assessment in composite material using Laser Doppler Vibrometry
    Willemann, DP
    Castellini, P
    Revel, GM
    Tomasini, EP
    SIXTH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER TECHNIQUES: ADVANCES AND APPLICATIONS, 2004, 5503 : 375 - 379
  • [8] A ROBUST FEATURE SELECTION METHOD FOR NONCONTACT BIOMETRICS BASED ON LASER DOPPLER VIBROMETRY
    Lai, Po-Hsiang
    O'Sullivan, Joseph A.
    Chen, Mei
    Sirevaag, Erik J.
    Kaplan, Alan D.
    Rohrbaugh, John W.
    2008 BIOMETRICS SYMPOSIUM (BSYM), 2008, : 65 - 70
  • [9] Noncontact Sensing of Facial Muscle Activity Using Laser Doppler Vibrometry: Time Domain Data Analysis
    Casaccia, S.
    Sirevaag, E. J.
    Frank, M. G.
    O'Sullivan, J. A.
    Scalise, L.
    Rohrbaugh, J. W.
    13TH INTERNATIONAL CONFERENCE ON VIBRATION MEASUREMENTS BY LASER AND NONCONTACT TECHNIQUES, 2018, 2018, 1149
  • [10] LASER DOPPLER VIBROMETRY
    不详
    HEWLETT-PACKARD JOURNAL, 1989, 40 (05): : 82 - 83