Single photon emission computed tomography myocardial perfusion imaging in patients with moderate to severe psoriasis

被引:2
|
作者
Sioka, Chrissa [1 ]
Moulias, Christos [2 ]
Voulgari, Paraskevi V. [3 ]
Fotopoulos, Andreas [1 ]
Bassukas, Ioannis D. [2 ]
机构
[1] Univ Hosp Ioannina, Med Sch, Dept Nucl Med, Ioannina, Greece
[2] Univ Hosp Ioannina, Med Sch, Dept Skin & Venereal Dis, Ioannina, Greece
[3] Univ Ioannina, Med Sch, Dept Internal Med, Rheumatol Clin, Ioannina, Greece
关键词
psoriasis; myocardial perfusion imaging; SPECT; myocardial ischaemia; perfusion defects; CARDIOVASCULAR EVENTS; INFLAMMATION; ISCHEMIA; DISEASE;
D O I
10.5603/NMR.2021.0014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Psoriasis is a chronic inflammatory disorder with an increased risk for coronary artery disease (CAD). This retro-spective study aimed to evaluate the rate of myocardial ischaemia in patients with psoriasis subjected to myocardial perfusion imaging (MPI). Material and methods: Twelve patients with moderate to severe psoriasis that had MPI were compared to 395 MPIs randomly retrieved from our MPIs pool data. All patients had a [Tc-99(m)]tetrofosmin stress - rest single-photon emission computer tomography ([Tc-99m]SPECT). Summed difference scores (SDS) were calculated for stress (SSS), rest (SIRS) and their difference (SDS = SSS - SIRS). Results: There was no significant difference in the frequency of abnormal MPI SPECT outcomes between patients with vs. without psoriasis (6/12 vs 214/395 respectively; p = 0.778). From the evaluation of SSS, SIRS and SDS, only the SDS scores of inadequately compensated resting perfusion defects were significantly lower in patients with psoriasis (p = 0.012). Conclusions: Patients with moderate-to-severe psoriasis had a similar rate of abnormal SSS scans compared to control patients. However, the SDS scans were significantly lower in patients with psoriasis indicating compromised reversibility of resting perfusion defects. Larger controlled studies are needed to verify these observations.
引用
收藏
页码:46 / 50
页数:5
相关论文
共 50 条
  • [1] Single-photon emission computed tomography myocardial perfusion imaging in patients with diabetes
    Noble G.L.
    Heller G.V.
    Current Cardiology Reports, 2005, 7 (2) : 117 - 123
  • [2] Attenuation correction for single photon emission computed tomography myocardial perfusion imaging
    Corbett J.R.
    Kritzman J.N.
    Ficaro E.P.
    Current Cardiology Reports, 2004, 6 (1) : 32 - 40
  • [3] PREDICTORS OF NORMAL SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION IMAGING
    Koh, Angela
    Flores, Jennifer
    Keng, Felix
    Chua, Terrance S. J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [4] Sequential single-photon emission computed tomography myocardial perfusion imaging
    Shaw, LJ
    Berman, DS
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (8A): : 28J - 39J
  • [5] Fusion imaging between myocardial perfusion single photon emission computed tomography and cardiac computed tomography
    Nakaura, T
    Utsunomiya, D
    Shiraishi, S
    Tomiguchi, S
    Kawanaka, K
    Honda, T
    Awai, K
    Yamashita, Y
    CIRCULATION, 2005, 112 (03) : E47 - E48
  • [6] Myocardial perfusion and function single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Daniel S. Berman
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    James R. Galt
    Ravi K. Garg
    Gary V. Heller
    Mark C. Hyun
    Lynne L. Johnson
    Benjamin D. McCallister
    Raymond Taillefer
    Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2006, 13 (6) : e97 - e120
  • [7] Myocardial perfusion and function: Single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Olakunle O. Akinboboye
    Daniel S. Berman
    Elias H. Botvinick
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    Regina S. Druz
    Edward P. Ficaro
    James R. Galt
    Ravi K. Garg
    Guido Germano
    Gary V. Heller
    Milena J. Henzlova
    Mark C. Hyun
    Lynne L. Johnson
    April Mann
    Benjamin D. McCallister
    Robert A. Quaife
    Terrence D. Ruddy
    Senthil N. Sundaram
    Raymond Taillefer
    R. Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2007, 14 (6) : e39 - e60
  • [8] Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    Bateman, TM
    Cullom, SJ
    SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) : 37 - 51
  • [9] Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
    Wu, MC
    Gao, DW
    Sievers, RE
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 576 - 582
  • [10] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483