Advanced exergy assessment of a solar absorption power cycle

被引:18
|
作者
Cao, Yan [1 ]
Rostamian, Fateme [2 ]
Ebadollahi, Mohammad [3 ]
Bezaatpour, Mojtaba [4 ]
Ghaebi, Hadi [2 ]
机构
[1] Xian Technol Univ, Sch Mechatron Engn, Xian 710021, Peoples R China
[2] Univ Mohaghegh Ardabili, Dept Mech Engn, Fac Engn, POB 179, Ardebil, Iran
[3] KN Toosi Univ Technol, Dept Energy Syst Engn, Fac Mech Engn, Pardis Ave, Tehran, Iran
[4] Sahand Univ Technol, Dept Mech Engn, Tabriz, Iran
关键词
Energy; Exergy; Advanced exergy; Absorption power cycle; Solar energy; ORGANIC RANKINE-CYCLE; TEMPERATURE HEAT-SOURCES; RENEWABLE ENERGY; SYSTEM; DRIVEN; ENGINE;
D O I
10.1016/j.renene.2021.11.039
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The present study investigates the advanced exergy assessment in a solar absorption power cycle to reveal the inefficiency of the system. Unlike simple exergy assessment, which only assesses exergy destruction, advanced exergy evaluates avoidable, unavoidable, exogenous, and endogenous exergy destructions. EES software is employed to model the proposed absorption power cycle, in which the power is generated using a low-temperature heat source driven by solar energy. The novelties of the present study are the use of solar energy in absorption power and applying the advanced exergy assessment. According to the results, the total energy and exergy efficiencies are 6.655% and 7.011% in the real state, 8.517% and 8.973% in the unavoidable state, and 9.433% and 9.938% in the ideal state, respectively. In other words, both efficiencies improve by 41.7% and 10.75% under ideal and unavoidable conditions compared to the real state, respectively. The outcomes reveal that the unavoidable exergy destruction is greater than the avoidable exergy destruction in the constituents, implying that no structural refinement can be effective in the system. Among the components, 73.69 kW exergy destruction occurs in the solar collector, of which 67.47 kW is endogenous destruction. Also, the unavoidable and avoidable exergy destructions equal 73.03 kW and 0.66 kW in the solar collector, respectively. Moreover, the unavoidable endogenous part accounts for the highest proportion of exergy destruction in the solar collector, while the avoidable exogenous destruction is less than zero. It means that by improving the component itself, it is possible to reduce the exergy destruction. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:561 / 574
页数:14
相关论文
共 50 条
  • [1] Exergy, Exergoeconomic, Exergoenvironmental, Emergy-based Assessment and Advanced Exergy-based Analysis of an Integrated Solar Combined Cycle Power Plant
    Nourpour, M.
    Manesh, M. H. Khoshgoftar
    Pirozfar, A.
    Delpisheh, M.
    [J]. ENERGY & ENVIRONMENT, 2023, 34 (02) : 379 - 406
  • [2] Energy and exergy analysis of an absorption power cycle
    Garcia-Hernando, Nestor
    de Vega, M.
    Soria-Verdugo, Antonio
    Sanchez-Delgado, Sergio
    [J]. APPLIED THERMAL ENGINEERING, 2013, 55 (1-2) : 69 - 77
  • [3] Study on Assessment of Life Cycle Exergy Analysis of PV Power System and Solar Thermal Power System
    Yue, Yongkui
    Yang, Zeliang
    Tian, Zhonghua
    [J]. POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 288 - 292
  • [4] Life cycle pollution exergy assessment of power plant
    Tian, ZH
    Yue, YK
    Chen, QL
    Hua, B
    [J]. ENERGY-EFFICIENT, COST-EFFECTIVE AND ENVIRONMENTALLY-SUSTAINABLE SYSTEMS AND PROCESSES, VOLS 1-3, 2004, : 979 - 986
  • [5] Advanced exergy analysis of a combined gas power cycle with humidification
    Mossi Idrissa, A. K.
    Goni Boulama, K.
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2020, 17 (15) : 990 - 1004
  • [6] Advanced exergy analysis of a combined Brayton/Brayton power cycle
    Idrissa, A. K. Mossi
    Boulama, K. Goni
    [J]. ENERGY, 2019, 166 : 724 - 737
  • [7] Exergy analysis of a solar combined cycle: organic Rankine cycle and absorption cooling system
    Grosu, Lavinia
    Marin, Andreea
    Dobrovicescu, Alexandru
    Queiros-Conde, Diogo
    [J]. INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 7 (04) : 449 - 459
  • [8] Energy, exergy and advanced exergy analyses on Garri 1 combined cycle power plant of Sudan
    Omara, Adil A.M.
    Mohammedali, Abubaker A.M.
    Dhivagar, R.
    [J]. International Journal of Thermofluids, 2024, 24
  • [9] Analysis of exergy destruction of integrated solar combined cycle system based on advanced exergy analysis method
    Wang, Shucheng
    Fu, Zhongguang
    Zhang, Gaoqiang
    Zhang, Tianqing
    Shi, Li
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (11): : 192 - 198
  • [10] Energy and exergy analyses of a solar assisted combined power and cooling cycle
    Ganjehsarabi, Hadi
    Asker, Mustafa
    Seyhan, Aslihan Kurnuc
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2016, : 1141 - 1145