Model-based glycaemic control in critical care-A review of the state of the possible

被引:60
|
作者
Chase, J. G. [1 ,2 ]
Shaw, G. M. [3 ]
Wong, X. W. [2 ]
Lotz, T. [2 ]
Lin, J. [2 ]
Hann, C. E. [2 ]
机构
[1] Univ Otago, Christchurch Sch Med & Hlth Sci, Dunedin, New Zealand
[2] Univ Canterbury, Dept Mech Engn, Ctr Bioengn, Christchurch 1, New Zealand
[3] Univ Otago, Christchurch Sch Med & Hlth Sci, Christchurch Hosp, Dept Intens Care, Dunedin, New Zealand
关键词
Critical care; Hyperglycemia; Control; Models; Blood glucose; Insulin; Review;
D O I
10.1016/j.bspc.2006.03.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Hyperglycaemia is prevalent in critical care, as patients experience stress-induced hyperglycaemia. even with no history of diabetes. Hyperglycaemia in critical care is not largely benign, as once thought, and it has a deleterious effect on outcome. Recent studies have shown that tight glucose regulation to average levels from 6.1-7.75 mmol/L can reduce mortality 25-43%, while also significantly reducing other negative clinical outcomes. However clinical results are highly variable and there is little agreement on what levels of performance call be achieved and how to achieve them. A typical clinical solution is to use ad-hoc protocols based primarily on experience, where large amounts of insulin, up to 50 U/h, are titrated against glucose measurements variably taken every 1-4 h. When combined with the unpredictable and sudden metabolic changes that characterise this aspect of critical illness and/or clinical changes in nutritional support. this approach results in highly variable blood glucose levels. The overall result is sustained periods of hyper- or hypo-glycaemia, characterised by oscillations between these states, which can adversely, affect clinical outcomes and mortality. The situation is exacerbated by exogenous nutritional Support regimes with high dextrose content. Hence, there is an emerging. strong,. need for the more rigorous analysis and methods that model-based control methods brim, to this type of problem. This paper reviews the state of the clinical and model-based control systems approach to the problem of managing hyperglycaemia in critical care. emphasising emerging methods and results. The overall goal is to present the fundamental problem and associated science and technologies involved. Thus. it is less a discussion of specific advantageous approaches than a presentation of the different factors that impact the problem and the different approaches taken to address them in the limited clinical engineering research done to date. These discussions are presented in the context of current and emerging clinical studies. both model-based and empirical protocol driven. Analogies to the Type I diabetes mellitus control problem are also noted where relevant and significant. Hence, it is more overview than specific analysis. where the overall conclusion is that there are many opportunities and unanswered questions remaining oil which model-based control research call have significant clinical impact. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3 / 21
页数:19
相关论文
共 50 条
  • [1] Model-based glycaemic control: methodology and initial results from neonatal intensive care
    Dickson, Jennifer L.
    Chase, J. Geoffrey
    Lynn, Adrienne
    Shaw, Geoffrey M.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2017, 62 (02): : 225 - 233
  • [2] Model-based glycaemic control: Methodology and initial results from neonatal intensive care
    Department of Mechanical Engineering, College of University of Canterbury, Private Bag 4800, Christchurch
    8140, New Zealand
    不详
    不详
    不详
    [J]. Biomed. Tech., 1600, 2 (225-233):
  • [3] Nutrition delivery of a model-based ICU glycaemic control system
    Kent W. Stewart
    J. Geoffrey Chase
    Christopher G. Pretty
    Geoffrey M. Shaw
    [J]. Annals of Intensive Care, 8
  • [4] Nutrition delivery of a model-based ICU glycaemic control system
    Stewart, Kent W.
    Chase, J. Geoffrey
    Pretty, Christopher G.
    Shaw, Geoffrey M.
    [J]. ANNALS OF INTENSIVE CARE, 2018, 8
  • [5] The metrics of glycaemic control in critical care
    Mackenzie, Iain M. J.
    Whitehouse, Tony
    Nightingale, Peter G.
    [J]. INTENSIVE CARE MEDICINE, 2011, 37 (03) : 435 - 443
  • [6] Glycaemic control in paediatric critical care
    Preissig, Catherine
    Rigby, Mark
    [J]. LANCET, 2009, 373 (9673): : 1423 - 1423
  • [7] The metrics of glycaemic control in critical care
    Iain M. J. Mackenzie
    Tony Whitehouse
    Peter G. Nightingale
    [J]. Intensive Care Medicine, 2011, 37 : 435 - 443
  • [8] Model-based regulation of glucose in critical care
    SP Gawel
    G Clermont
    RS Parker
    [J]. Critical Care, 16 (Suppl 1):
  • [9] Modeling endogenous glucose production for model-based tight glycaemic control in the neonatal intensive care unit
    Dickson, J. L.
    Hewett, J. N.
    Pretty, C. G.
    Gunn, C. A.
    Lynn, A.
    Shaw, G. M.
    Chase, J. G.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S975 - +
  • [10] Model-based Glycemic Control Using Subcutaneous Insulin for Infants in Critical Care
    Zhou, T.
    Boettger, M.
    Knopp, J.
    Lange, M.
    Heep, A.
    Chase, J. Geoffrey
    [J]. IFAC PAPERSONLINE, 2023, 56 (02): : 3021 - 3026