Measurement of photon and neutron doses outside the treatment field for prostate patients undergoing 18 MV IMRT

被引:3
|
作者
Reft, C
Muller-Runkel, R
Myrianthopoulos, L
机构
[1] Univ Chicago, Chicago, IL 60637 USA
[2] St Margaret Mercy Healthcare Ctr, Hammond, IN USA
关键词
D O I
10.1118/1.1998264
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: For IMRT treatments 6 MV photons are typically used, however, for deep seated tumors in the pelvic region, higher photon energies are increasingly being employed. IMRT treatments require more monitor units (MUs) to deliver the same dose as conformal treatments, causing increased secondary radiation from leakage and scatter, as well as a possible increase in the neutron dose from photon interactions in the machine head. Here we provide in‐vivo and phantom measurements of the photon secondary radiation and the neutron dose equivalent for 18 MV IMRT treatments. Method and Materials: We use different detectors with various photon and neutron sensitivities: TLD 600 and TLD 700 chips, a Neutrak detector containing Al〈sub〉2〈/sub〉O〈sub〉3〈/sub〉 to detect photons using optically stimulated radiation and a CR‐39 plastic sheet using track etching for neutrons from Landauer, and a separate CR‐39 detector from Argonne National Labs. In ‐vivo patient measurements were obtained outside the field edge for 9 prostate patients undergoing 18 MV IMRT on two different commercial accelerators. We also compared the secondary photon dose for 6 prostate patients undergoing 6 MV IMRT with that for 18 MV IMRT. Additionally, a 25.4 cm diameter Bonner sphere containing TLD 700 and TLD 600 was used to compare the out of field secondary doses for typical 18 MV IMRT and 18 MV six‐field conformal prostate treatments. Results: The patient measurements showed photon doses approximately 12 and 7 times greater than the neutron dose equivalent at 10 and 20 cm from the field edge, respectively. Initial Bonner sphere measurements showed neutron doses for IMRT greater than for conformal treatments. Conclusion: For prostate treatment the photon secondary dose for 18 MV and 6 MV IMRT are similar, and the neutron dose is higher than the dose from 18 MV conformal treatments by about the ratio of MUs. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2059 / 2060
页数:2
相关论文
共 30 条
  • [1] In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing 18 MV IMRT
    Reft, Chester S.
    Runkel-Muller, Renate
    Myrianthopoulos, Leon
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3734 - 3742
  • [2] Comparison of out-of-field photon doses in 6 MV IMRT and neutron doses in proton therapy for adult and pediatric patients
    Athar, Basit S.
    Bednarz, Bryan
    Seco, Joao
    Hancox, Cindy
    Paganetti, Harald
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : 2879 - 2891
  • [3] Measurement of neutron dose for IMRT plans using 23MV photon beam
    Bose, SR
    Brandner, ED
    Selvaraj, RN
    Bahri, S
    Wu, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S588 - S589
  • [4] IMRT treatment of prostate cancer using 6MV photon beam
    Huang, J
    Katz, A
    Haas, J
    Urrutia, T
    Lauritano, J
    MacMelville, W
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1254 - 1254
  • [5] Neutron dose measurement in Intensity Modulated Radiotherapy of 18 MV photon beams
    Chern, SS
    Selvaraj, RN
    Sheetz, M
    Wu, A
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1267 - 1268
  • [6] Dosimetric comparison of 3D-CRT vs IMRT: photon and neutron doses outside the radiation beam
    Kowalik, A.
    Jackowiak, W.
    Malicki, J.
    Skorska, M.
    Adamczyk, M.
    Konstanty, E.
    Piotrowski, T.
    Polaczek-Grelik, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S593 - S593
  • [7] A Neutron Measurement Comparison of Varian and Elekta 10&18 MV Photon Beams
    Chen, K.
    Klein, E.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [8] A MEASUREMENT OF DOSES TO THE NECK FOR MANTLE FIELD TREATMENT OF LYMPHOMAS WITH CO-60, 4-MV AND 10-MV PHOTON BEAMS
    MCCULLOUGH, EC
    EARLE, JD
    [J]. RADIOLOGY, 1982, 144 (02) : 432 - 434
  • [9] Treatment planning and delivery of IMRT using 6 and 18 MV photon beams without flattening filter
    Stathakis, Sotirios
    Esquivel, Carlos
    Gutierrez, Alonso
    Buckey, Courtney R.
    Papanikolaou, Niko
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (09) : 1629 - 1637
  • [10] The out-of-field dose measurement of neutron and photon during radiotherapy with 20MV
    Kruszyna, M.
    Malicki, J.
    Adamczyk, S.
    Kowalik, A.
    Jackowiak, W.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S286 - S286