Heating control strategy for variable refrigerant flow air conditioning system with multi-module outdoor units

被引:21
|
作者
Tu, Qiu [1 ,2 ]
Feng, Ziping [1 ,2 ]
Mao, Shoubo [3 ]
Dong, Kaijun [1 ,2 ]
Xiao, Rui [1 ,2 ]
Song, Wenji [1 ,2 ]
机构
[1] Chinese Acad Sci, Key Lab Renewable Energy & Gas Hydrate, Guangzhou 510640, Guangdong, Peoples R China
[2] Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China
[3] Haier Air Conditioning Elect Co LTD, Qingdao 266510, Peoples R China
关键词
Variable refrigerant flow; Inverter; Heating; Control strategy; Frequency;
D O I
10.1016/j.enbuild.2010.06.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The heating control strategy is key technology for stable and reliable heating operation of variable refrigerant flow air conditioning system with multi-module outdoor units. The synoptic control strategy is that the host module coordinates the system operation and adjusts the operation frequency of every module based on equal frequency allocation principle for suction pressure balance among modules. The heating control model including heating frequency adjustment, module switching condition and frequency allocation model has been built. Considering the discharge pressure disturbance, a certain discharge pressure region is taken as the control objective to adjust the frequency. And considering the lag between pressure and frequency, the restriction condition of discharge pressure and a certain judgment time are introduced into the model to avoid frequent module switching. Furthermore, different frequency allocation models have been built for increase and decrease of module number. In the model, when the module number increases and evenly allotted frequency to every module is less 70 Hz, one or two certain frequencies 70 Hz are distributed to the pre-existing thermo-on module(s) and the remaining frequency is distributed to ensuing thermo-on module so as to avoid sharp frequency fluctuation and inferior heating effect. Experiments demonstrate the feasibility of the control strategy. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2021 / 2027
页数:7
相关论文
共 50 条
  • [1] Heating control strategy in fresh air processor matched with variable refrigerant flow air conditioning system
    Tu, Qiu
    Mao, Shoubo
    Feng, Yuhai
    Guo, Defang
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2542 - 2554
  • [2] Simulation of variable refrigerant flow air conditioning system in heating mode combined with outdoor air processing unit
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fang, Xing
    [J]. ENERGY AND BUILDINGS, 2014, 68 : 571 - 579
  • [3] A hybrid control strategy for frequency regulation with variable refrigerant flow air conditioning system
    Zhou, Fenglin
    Li, Yaoyu
    Dong, Liujia
    [J]. ENERGY AND BUILDINGS, 2024, 303
  • [4] Investigation on output capacity control strategy of variable refrigerant flow air conditioning system with multi-compressor
    Tu, Qiu
    Zou, Deqiu
    Deng, Chenmian
    Zhang, Jie
    Hou, Lifeng
    Yang, Min
    Nong, Guicai
    Feng, Yuhai
    [J]. APPLIED THERMAL ENGINEERING, 2016, 99 : 280 - 290
  • [5] Control and energy simulation of variable refrigerant flow air conditioning system combined with outdoor air processing unit
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    Fan, Bo
    [J]. APPLIED THERMAL ENGINEERING, 2014, 64 (1-2) : 385 - 395
  • [6] Super-heating degree responsive control strategy of variable refrigerant flow air conditioning system for energy saving and stable operation
    Tu, Qiu
    Zhang, Lina
    Yuan, Xiaoyuan
    Jiang, Jianjun
    Ye, Fangming
    [J]. ENERGY SCIENCE & ENGINEERING, 2023, 11 (09) : 3215 - 3231
  • [7] Coordinated optimization of the variable refrigerant flow and variable air volume combined air-conditioning system in heating conditions
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    He, Chao
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 904 - 916
  • [8] Optimal control of combined air conditioning system with variable refrigerant flow and variable air volume for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Fang, Xing
    Du, Zhimin
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 42 : 14 - 25
  • [9] Generic simulation model of multi-evaporator variable refrigerant flow air conditioning system for control analysis
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fu, Sijie
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (06): : 1602 - 1615
  • [10] Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fang, Xing
    [J]. APPLIED THERMAL ENGINEERING, 2015, 80 : 87 - 96