Region of interest (ROI) computed tomography (CT): Comparison with full field of view (FFOV) and truncated CT for a human head phantom

被引:29
|
作者
Chityala, R [1 ]
Hoffmann, KR [1 ]
Rudin, S [1 ]
Bednarek, DR [1 ]
机构
[1] SUNY Buffalo, Dept Neurosurg, Buffalo, NY 14214 USA
关键词
region of interest CT; ROI CT; volume of interest CT; VOICT; area of interest CT; artifact reduction; dose reduction; reduced FOV; truncated reconstruction;
D O I
10.1117/12.595430
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone-beam CT reconstruction can be performed at lower integral dose, by using a non-uniform beam filter between the x-ray source and the patient to obtain good image quality within an ROI with minimal artifacts. To evaluate the method, a human head phantom was placed on a rotary stage. Cone-beam projection images of the phantom were obtained with and without an ROI filter (dose reduction factor similar to 7). A mapping function was established to equalize the intensity outside the ROI (to compensate for the attenuation by the filter) to the intensity inside by assuming that those features lying both inside and outside very close to the edge of the ROI are the same. Reconstructed images were obtained using equalized projection images for 2 cases: one in which the outside region was smoothed using an averaging filter and the other with no smoothing outside. In addition, a third case was simulated by calculating the average pixel value inside the ROI for each image and assigning this value to all pixels outside the ROI for that image. The images were then back projected using a Feldkamp algorithm. We found that the three cases yield results inside the ROI comparable to those obtained using FFOV projections. In addition, the ROI filter reconstruction with smoothing provides image information outside the ROI comparable to the FFOV reconstruction. CT using an ROI filter provides a means to reconstruct reliable 3D for a volume of interest with greatly reduced integral dose compared to FFOV projections and with minimal artifacts.
引用
收藏
页码:583 / 590
页数:8
相关论文
共 31 条
  • [1] Impact of Reconstruction Field of View On Radiomics Features in Computed Tomography (CT) Using a Texture Phantom
    ul Hassan, M. Shafiq
    Zhang, G.
    Latifi, K.
    Oliver, J.
    Hunt, D.
    Guzman, R.
    Balagurunathan, Y.
    Mackin, D.
    Court, L.
    Gillies, R.
    Moros, E.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3705 - 3705
  • [2] The reliability of computed tomography (CT) values and dimensional measurements of the oropharyngeal region using cone beam CT: comparison with multidetector CT
    Yamashina, A.
    Tanimoto, K.
    Sutthiprapaporn, P.
    Hayakawa, Y.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) : 245 - 251
  • [3] 3D Region-of-Interest (ROI) Reconstruction from Truncated Data in Circular Cone-beam CT
    Li, Liang
    Kang, Kejun
    Chen, Zhiqiang
    Zhang, Li
    Xing, Yuxiang
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4409 - 4412
  • [4] Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images
    Ozemre, Mehmet Ozgur
    Gulsahi, Ayse
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (07)
  • [5] Comparison of defect detectability between Computed Tomography inspection and CT simulation using a calibrated defect phantom
    Galleguillos, Carlos
    Senck, Sascha
    Vilches, Celia
    Rendl, Sarah
    Lasagni, Fernando
    [J]. e-Journal of Nondestructive Testing, 2022, 27 (03):
  • [6] Surface Reconstruction from Computed Tomography (CT) Image of Human Head with the Effect of Noise
    Abd Halim, Suhaila
    Abd Halim, Muhammad Syawal
    Hadi, Normi Abdul
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MATHEMATICS, ENGINEERING AND INDUSTRIAL APPLICATIONS 2018 (ICOMEIA 2018), 2018, 2013
  • [7] Comprehensive evaluations of a prototype full field-of-view photon counting CT system through phantom studies
    Zhan, Xiaohui
    Zhang, Ruoqiao
    Niu, Xiaofeng
    Hein, Ilmar
    Budden, Brent
    Wu, Shuoxing
    Markov, Nicolay
    Clarke, Cameron
    Qiang, Yi
    Taguchi, Hiroki
    Nomura, Keiichi
    Muramatsu, Yoshihisa
    Yu, Zhou
    Kobayashi, Tatsushi
    Thompson, Richard
    Miyazaki, Hiroaki
    Nakai, Hiroaki
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (17):
  • [8] Reconstruction of Region-of-interest Image in Narrow-field-of-view Computed Tomography without Prior Constraints
    Enjilela, Esmaeil
    Hussein, Esam M. A.
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (05) : 431 - 438
  • [9] The effects of field-of-view and patient size on CT numbers from cone-beam computed tomography
    Seet, Katrina Y. T.
    Barghi, Arvand
    Yartsev, Slav
    Van Dyk, Jake
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20): : 6251 - 6262
  • [10] Comparison of cerebral blood flow (CBF) data obtained by perfusion CT (PCT) with that obtained by xenon CT (XeCT) using 320-row CT and automated region of interest (ROI) determining software
    Takahashi, S.
    Tanizaki, Y.
    Kimura, H.
    Akaji, K.
    Kano, T.
    Suzuki, K.
    Takayama, Y.
    Kanzawa, T.
    Nakazawa, M.
    Mihara, B.
    [J]. CEREBROVASCULAR DISEASES, 2014, 37 : 494 - 494