Evaluation of Image Based Spatially Variant and Count Rate Dependant Point Spread Functions on the HRRT PET scanner

被引:0
|
作者
Kotasidis, Fotis A. [1 ,2 ]
Angelis, Georgios I. [1 ,2 ]
Henderson, Jack [3 ]
Buckley, Anna [3 ]
Markiewicz, Pawel J. [1 ,2 ]
Green, Michael [1 ,2 ]
Anton-Rodriguez, Jose
Lionheart, William R. [4 ]
Reader, Andrew J. [5 ]
Matthews, Julian C. [1 ,2 ]
机构
[1] Univ Manchester, Wolfson Mol Imaging Ctr, Sch Canc & Enabling Sci, MAHSC, Manchester M13 9PL, Lancs, England
[2] Univ Manchester, Sch Canc & Enabling Sci, MAHSC, Wolfson Mol Imaging Ctr, Manchester M13 9PL, Lancs, England
[3] Univ Manchester, Sch Phys & Astron, Manchester M13 9PL, Lancs, England
[4] Univ Manchester, Sch Math, Manchester M13 9PL, Lancs, England
[5] McGill Univ, Montreal Neurol Inst, Montreal, PQ, Canada
基金
英国工程与自然科学研究理事会;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Spatial resolution is of high importance especially in preclinical and brain PET imaging and characterization of the scanner's resolution properties requires measuring its point spread function (PSF). In our previous work we measured the PSF in 2 PET/eT scanners using a printed point source array. Here we extend the work to accurately measure the spatial variation of the PSF on the High Resolution Research Tomograph (HRRT) and assess the impact of the scanner's depth of interaction (DOI) capability on the spatial resolution. Furthermore we characterize the dependency of the PSF to count rate. An array of 15x11 printed sources was scanned twice, initially on its own (10min scan) and subsequently with an extension line containing similar to 300MBq of carbon-11 at the scan starts (15 x 10min contiguous frames). Data were reconstructed with OP-OSEM and invariant PSF OP-OSEM. The PSF was found to be radially dependent in all directions but importantly radially symmetric and almost axially independent. The FWHM improves by similar to 1.3mm using the PSF-OP-OSEM but is still radially variable with almost 1 mm degradation within the boundaries within which the brain is typically located. When DOI was not taken into account, a degradation up to 0.7mm was seen in the radial FWHM. In terms of count rate dependency, a clear resolution deterioration was seen, for count rates above 5-10 kcps with such count rates observed during many clinical scans.
引用
收藏
页码:3595 / +
页数:2
相关论文
共 50 条
  • [1] Image-Based Spatially Variant and Count Rate Dependent Point Spread Function on the HRRT
    Kotasidis, Fotis A.
    Angelis, Georgios I.
    Anton-Rodriguez, Jose
    Markiewicz, Pawel
    Lionheart, William R.
    Reader, Andrew J.
    Matthews, Julian C.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (03) : 1192 - 1202
  • [2] Comparison of estimated and measured isotope specific spatially variant point spread functions on the HRRT PET scanner
    Rodriguez, J. M. Anton
    Krokos, G.
    Asselin, M.
    Kotasidis, F.
    Julyan, P.
    Archer, A.
    Morris, O.
    Matthews, J. C.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S460 - S460
  • [3] Photoacoustic Tomography Image Restoration With Measured Spatially Variant Point Spread Functions
    Qi, Li
    Wu, Jian
    Li, Xipan
    Zhang, Shuangyang
    Huang, Shixian
    Feng, Qianjin
    Chen, Wufan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (09) : 2318 - 2328
  • [4] Multiple-image deblurring with spatially-variant point spread functions
    Vio, R
    Nagy, J
    Wamsteker, A
    [J]. ASTRONOMY & ASTROPHYSICS, 2005, 434 (02) : 795 - U23
  • [5] Experimental Evaluation and Image Reconstruction Based Optimization of the Spatially Variant PSF on the Ingenuity TF PET/MR Scanner
    Kotasidis, Fotis A.
    Heinzer, Susanne
    Zaidi, Habib
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2921 - 2924
  • [6] Spatially variant point spread function for PET rigid motion correction
    Miranda, Alan
    Stroobants, Sigrid
    Staelens, Steven
    Verhaeghe, Jeroen
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [7] STRONG GRAVITATIONAL LENS MODELING WITH SPATIALLY VARIANT POINT-SPREAD FUNCTIONS
    Rogers, Adam
    Fiege, Jason D.
    [J]. ASTROPHYSICAL JOURNAL, 2011, 743 (01):
  • [8] Massively parallel image restoration with spatially variant point-spread-function
    Gorman, G
    Wilson, N
    Butler, R
    Shearer, A
    [J]. PDPTA'2001: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED PROCESSING TECHNIQUES AND APPLICATIONS, 2001, : 1073 - 1079
  • [9] Full Field Spatially-Variant Image-Based Resolution Modelling Reconstruction for the HRRT
    Angelis, Georgios I.
    Kotasidis, Fotis A.
    Matthews, Julian C.
    Markiewicz, Pawel J.
    Lionheart, William R.
    Reader, Andrew J.
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3434 - 3438
  • [10] Full field spatially-variant image-based resolution modelling reconstruction for the HRRT
    Angelis, Georgios I.
    Kotasidis, Fotis A.
    Matthews, Julian C.
    Markiewicz, Pawel J.
    Lionheart, William R.
    Reader, Andrew J.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (02): : 137 - 145