Comparison of retention and fracture load of endocrowns made from zirconia and zirconium lithium silicate after aging: an in vitro study

被引:15
|
作者
Sahebi, Majid [1 ,2 ]
Ghodsi, Safoura [1 ,2 ]
Berahman, Parsia [1 ,2 ]
Amini, Amirhesam [1 ,2 ]
Zeighami, Somayeh [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Dent Res Ctr, Dent Res Inst, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Dent, Dept Prosthodont, Tehran, Iran
关键词
CAD-CAM; Compressive strength; Dental prosthesis retention; Endocrown; Zirconia; ENDODONTICALLY TREATED TEETH; BIOMECHANICAL BEHAVIOR; TOOTH;
D O I
10.1186/s12903-022-02072-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background This study aimed to compare retention and fracture load in endocrowns made from translucent zirconia and zirconium lithium silicate. Methods Fifty-six intact human maxillary molars after being mounted in acrylic resin, were scanned to acquire biogeneric copies. Specimens underwent standard endodontic treatment and were prepared for endocrown up to 2 mm above the cementoenamel junction. The specimens were randomly divided into two groups of 28, and endocrowns were designed using biogeneric copies and milled from high-translucent zirconia disks (Zr) and zirconium lithium silicate blocks (ZLS). After cementation with dual-cure resin cement, all the specimens underwent thermomechanical aging, and pull-out retention test and compressive test were conducted (14 specimens were used for each test in each group, n = 14), and failure modes in both tests were evaluated. Results Independent samples t-test showed significant difference between the retention of Zr (271.5 N +/- 114.31) and ZLS (654.67 N +/- 223.17) groups (p value = 0.012). Compressive test results were also significantly different between Zr (7395.07 N +/- 1947.42) and ZLS (1618.3 N +/- 585) (p = 0.002). Failure mode of retention test was primarily adhesive failure at the cement-restoration interface in Zr group and cement-tooth interface in ZLS group. Failure modes of fracture test for Zr group were 7 non-restorable fractures and one restorable fracture while 6 specimens resisted compressive loads up to 8500 N without fracture. ZLS group showed 7 restorable and 7 non-restorable failures. Conclusions Zr endocrowns showed significantly lower retention and higher fracture strength. Both materials seem to be suitable for fabrication of endocrown in clinical setup.
引用
收藏
页数:8
相关论文
共 13 条
  • [1] Comparison of retention and fracture load of endocrowns made from zirconia and zirconium lithium silicate after aging: an in vitro study
    Majid Sahebi
    Safoura Ghodsi
    Parsia Berahman
    Amirhesam Amini
    Somayeh Zeighami
    [J]. BMC Oral Health, 22
  • [2] Comparison of Marginal and Internal Adaptation in Endocrowns Milled from Translucent Zirconia and Zirconium Lithium Silicate
    Amini, Amirhesam
    Zeighami, Somayeh
    Ghodsi, Safoura
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [3] Comparison of clinical efficacy of CAD CAM Endocrowns made of feldspathic ceramic, zirconia lithium silicate, and lithium disilicate: A two-year mixed cohort study
    Jalali, Samar
    Asgari, Nafiseh
    Pirooz, Parsa
    Younespour, Shima
    Atri, Faezeh
    [J]. JOURNAL OF DENTISTRY, 2024, 149
  • [4] In-Vitro Comparison of Fracture Strength of Endocrowns and Overlays in Endodontically Treated Teeth Manufactured with Monolithic Lithium Disilicate and Zirconia
    Veselinova, Maya
    Diamantopoulou, Sofia
    Paximada, Chariklia
    Papazoglou, Efstratios
    [J]. JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (08)
  • [5] Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study
    El Shahawy, Osama Ibrahim
    Azab, Maha Moussa
    [J]. BMC ORAL HEALTH, 2022, 22 (01)
  • [6] Fracture resistance of prefabricated versus custom-made zirconia crowns after thermo-mechanical aging: an in-vitro study
    Osama Ibrahim El Shahawy
    Maha Moussa Azab
    [J]. BMC Oral Health, 22
  • [7] Fracture Resistance of Zirconia-Reinforced Lithium Silicate Ceramic Crowns Cemented with Conventional or Adhesive Systems: An In Vitro Study
    D'Addazio, Gianmaria
    Santilli, Manlio
    Rollo, Marco Lorenzo
    Cardelli, Paolo
    Rexhepi, Imena
    Murmura, Giovanna
    Husain, Nadin Al-Haj
    Sinjari, Bruna
    Traini, Tonino
    Ozcan, Mutlu
    Caputi, Sergio
    [J]. MATERIALS, 2020, 13 (09)
  • [8] In vitro comparison of fracture load of implant-supported, zirconia-based, porcelain- and composite-layered restorations after artificial aging
    Komine, Futoshi
    Taguchi, Kohei
    Fushiki, Ryosuke
    Kamio, Shingo
    Iwasaki, Taro
    Matsumura, Hideo
    [J]. DENTAL MATERIALS JOURNAL, 2014, 33 (05) : 607 - 613
  • [9] Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia—an in vitro study
    Julian Groesser
    Caroline Sachs
    Philipp Heiß
    Markus Stadelmann
    Kurt Erdelt
    Florian Beuer
    [J]. Clinical Oral Investigations, 2014, 18 : 1173 - 1179
  • [10] Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia-an in vitro study
    Groesser, Julian
    Sachs, Caroline
    Heiss, Philipp
    Stadelmann, Markus
    Erdelt, Kurt
    Beuer, Florian
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (04) : 1173 - 1179