Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

被引:53
|
作者
Schouten, Martijn G. [1 ,2 ]
Bomers, Joyce G. R. [2 ]
Yakar, Derya [2 ]
Huisman, Henkjan [2 ]
Rothgang, Eva [3 ,4 ]
Bosboom, Dennis [2 ]
Scheenen, Tom W. J. [2 ]
Misra, Sarthak [5 ]
Futterer, Jurgen J. [2 ]
机构
[1] Univ Med Ctr Nijmegen, Dept Radiol, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiol, Med Ctr, NL-6525 ED Nijmegen, Netherlands
[3] Univ Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
[4] Siemens Corp Res, Ctr Appl Med Imaging, Baltimore, MD USA
[5] Univ Twente, MIRA Inst Biomed Technol & Tech Med, NL-7500 AE Enschede, Netherlands
关键词
Transrectal; Prostate; MR-guided; Biopsy; Robot; NEEDLE INSERTION METHOD; CANCER; SYSTEM; BRACHYTHERAPY; ACCURACY; PROOF;
D O I
10.1007/s00330-011-2259-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 50 条
  • [1] Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies
    Martijn G. Schouten
    Joyce G. R. Bomers
    Derya Yakar
    Henkjan Huisman
    Eva Rothgang
    Dennis Bosboom
    Tom W. J. Scheenen
    Sarthak Misra
    Jurgen J. Fütterer
    [J]. European Radiology, 2012, 22 : 476 - 483
  • [2] MRI-Guided Transrectal Robotic Prostate Biopsy Validation
    Xu, H.
    Lasso, A.
    Vikal, S.
    Guion, P.
    Krieger, A.
    Kaushal, A.
    Whitcomb, L.
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3128 - +
  • [3] Target Motion Tracking in MRI-guided Transrectal Robotic Prostate Biopsy
    Tadayyon, Hadi
    Lasso, Andras
    Kaushal, Aradhana
    Guion, Peter
    Fichtinger, Gabor
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (11) : 3135 - 3142
  • [4] In-bore transrectal MRI-guided prostate biopsies: Are there risk factors for complications?
    Meier-Schroers, Michael
    Homsi, Rami
    Kukuk, Guido
    Wolter, Karsten
    Decker, Georges
    Fischer, Stefan
    Marx, Christian
    Schmeel, Frederic Carsten
    Block, Wolfgang
    Sprinkart, Alois Martin
    Traeber, Frank
    Schild, Hans Heinz
    Willinek, Winfried
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (12) : 2169 - 2173
  • [5] Biopsy Needle Artifact Localization in MRI-Guided Robotic Transrectal Prostate Intervention
    Song, Sang-Eun
    Cho, Nathan Bongjoon
    Iordachita, Iulian I.
    Guion, Peter
    Fichtinger, Gabor
    Kaushal, Aradhana
    Camphausen, Kevin
    Whitcomb, Louis L.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (07) : 1902 - 1911
  • [6] Biological MRI-guided transrectal prostate biopsy
    Grubb, RL
    Susil, R
    Krieger, A
    Guion, P
    Ullman, KL
    Metzger, G
    Smith, SL
    Singh, AK
    Linehan, WM
    Camphausen, K
    Coleman, CN
    Atalar, E
    Choyke, P
    Ménard, C
    Coleman, J
    [J]. JOURNAL OF UROLOGY, 2005, 173 (04): : 364 - 364
  • [7] 18F-Choline PET/MRI: The Additional Value of PET for MRI-Guided Transrectal Prostate Biopsies
    Piert, Morand
    Montgomery, Jeffrey
    Kunju, Lakshmi Priya
    Siddiqui, Javed
    Rogers, Virginia
    Rajendiran, Thekkelnaycke
    Johnson, Timothy D.
    Shao, Xia
    Davenport, Matthew S.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (07) : 1065 - 1070
  • [8] 18F-choline PET/MRI: the Additional Value of PET for MRI-guided Transrectal Prostate Biopsies
    Piert, Morand
    Montgomery, Jeffrey
    Kunju, Lakshmi
    Shao, Xia
    Davenport, Matthew
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [9] A Technique for MRI-Guided Transrectal Deep Pelvic Abscess Drainage
    Nour, Sherif Gamal
    Derakhshan, Jamal J.
    Akhtar, Nila J.
    Ayres, Martin A.
    Clampitt, Mark E.
    Stellato, Thomas A.
    Duerk, Jeffrey L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) : 1182 - 1185
  • [10] Accuracy analysis in MRI-guided robotic prostate biopsy
    Xu, Helen
    Lasso, Andras
    Guion, Peter
    Krieger, Axel
    Kaushal, Aradhana
    Singh, Anurag K.
    Pinto, Peter A.
    Coleman, Jonathan
    Grubb, Robert L., III
    Lattouf, Jean-Baptiste
    Menard, Cynthia
    Whitcomb, Louis L.
    Fichtinger, Gabor
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (06) : 937 - 944