ENERGY CONSUMPTION ANALYSIS OF RESIDENTIAL CENTRAL AIR CONDITIONING SYSTEMS

被引:0
|
作者
Wei Bing [1 ]
Yang Huayi [1 ]
机构
[1] N China Elect Power Univ, Sch Energy & Power Engn, Baoding 071003, Hebei, Peoples R China
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Nowadays the energy crisis has been more and more severe all over the world. In China there is enormous energy source, but due to the large number of population, the average possession of the total energy is lower, and the energy supply is relatively less. Enormous energy consumption of air conditioning systems in the residential buildings makes the energy conservation more important. The residential central air conditioning systems are being widely used due to its advantages of easy control and low operating cost. But there are still many problems to be resolved, of which the energy consumption of the residential central air-conditioning systems is a hot issue. The main cold and heat sources for residential central air conditioning systems are air-cooled heat pump unit, household gas air conditioning unit, air-cooled chiller unit/gas-fired boiler and water loop heat pump unit. The terminal facilities suited for the anterior three units are the fan coil units, and the terminal of the last water loop heat pump unit is normally indoor unit. The combined utilization of the heat and cold source units with their terminal units keep the indoor environment in desired state all the year. In this paper, based on an actual example, the basic principles of four systems mentioned above are outlined and analyzed, and four schemes are compared. By using the method of equivalent weight full load operation time, the annual energy consumptions of the four schemes are calculated and analyzed. Comparing the annual primary energy consumption of four schemes, the following conclusions can be drawn: in the case studied, the energy consumption of the household gas-fired air conditioning unit with fan coil system is the maximum, the consumption of the air-cooled chiller unit/gas-fired boiler with fan coil system is the next, then is the air-cooled heat pump with fan coil system, and that of the water loop heat pump system is the minimum. It can be observed that the water loop heat pump system is the optimal one and is the best on energy conservation. Through the study of this paper, the minimum energy consumption system is chosen so as to give the references for the energy savings of air-conditioning systems in the practice.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [1] Primary Energy Consumption Analysis of Residential Central Air Conditioning Systems
    Wei Bing
    Yang Huayi
    Wei Zhe
    [J]. ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 2, 2010, : 292 - 295
  • [2] Exergy Analysis of Energy Consumption for Central Air Conditioning System
    Xia, Xiaoxia
    Zhou, Naijun
    Wang, Zhiqi
    [J]. MATERIALS SCIENCE, MECHANICAL ENGINEERING AND APPLIED RESEARCH, 2014, 628 : 332 - 337
  • [3] ECONOMIC EVALUATION OF RESIDENTIAL CENTRAL AIR CONDITIONING SYSTEMS
    Wei Bing
    Yang Huayi
    Luo Wen
    [J]. ES2010: PROCEEDINGS OF ASME 4TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 1, 2010, : 363 - 370
  • [4] Energy Audit Analysis of Residential Air-Conditioning Systems in Austin, Texas
    Rhodes, Joshua
    Stephens, Brent
    Webber, Michael E.
    [J]. ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 143 - 150
  • [5] Anomaly detection method of daily energy consumption patterns for central air conditioning systems
    Zhou, Xuan
    Yang, Tao
    Liang, Liequan
    Zi, Xuehui
    Yan, Junwei
    Pan, Dongmei
    [J]. JOURNAL OF BUILDING ENGINEERING, 2021, 38
  • [6] INFLUENCE OF RESIDENTIAL VENTILATION MODE ON ENERGY CONSUMPTION OF AIR CONDITIONING AND HEATING
    Yang, Y. X.
    Wang, Z. C.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1079 - 1086
  • [7] COMPARATIVE STUDY OF ENERGY CONSUMPTION FOR AIR CONDITIONING BETWEEN RESIDENTIAL BUILDINGS WITH TWO DIFFERENT SUBFLOORING SYSTEMS
    Albayyaa, H.
    Hagare, D.
    Saha, S.
    [J]. PROCEEDINGS OF INTERNATIONAL STRUCTURAL ENGINEERING AND CONSTRUCTION: INTERACTION BETWEEN THEORY AND PRACTICE IN CIVIL ENGINEERING AND CONSTRUCTION, 2016, : 615 - 619
  • [8] Energy Management by Controlling Air Conditioning Systems in Residential Settings
    Gubba, Sai Ram
    Li, Wen-Tai
    Tushar, Wayes
    Yuen, Chau
    Ul Hassan, Naveed
    Wood, Kristin
    Wen, Chao-Kai
    Poor, H. Vincent
    [J]. 2016 IEEE WORKSHOP ON ENVIRONMENTAL, ENERGY, AND STRUCTURAL MONITORING SYSTEMS (EESMS), 2016,
  • [9] Measuring and Analysis on Energy Consumption of Variable Air Volume (VAV) Central Air-conditioning System
    Ren, Qingchang
    Guo, Shangyi
    Lei, Xiaofeng
    Yan, Weijia
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 516 - 519
  • [10] Effect of Room Temperature Set Points on Energy Consumption in a Residential Air Conditioning
    Sunardi, Cecep
    Hikmat, Yudi Prana
    Margana, Ade Suryatman
    Sumeru, Kasni
    Bin Sukri, Mohamad Firdaus
    [J]. 10TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS 2019 (THERMOFLUID X), 2020, 2248