A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease

被引:48
|
作者
Funatsu, Atsushi [1 ,10 ]
Nakamura, Shigeru [1 ]
Inoue, Naoto [2 ]
Nanto, Shinsuke [3 ]
Nakamura, Masato [4 ]
Iwabuchi, Masashi [5 ]
Ando, Kenji [5 ]
Asano, Ryuta [6 ]
Habara, Seiji [7 ]
Saito, Shigeru [8 ]
Kozuma, Ken [9 ]
Mitsudo, Kazuaki [7 ]
机构
[1] Kyoto Katsura Hosp, Kyoto, Japan
[2] Sendai Kousei Hosp, Sendai, Miyagi, Japan
[3] Osaka Univ, Grad Sch Med, Osaka, Japan
[4] Toho Univ, Ohashi Med Ctr, Tokyo, Japan
[5] Kokura Mem Hosp, Kitakyushu, Fukuoka, Japan
[6] Sakakibara Heart Inst, Tokyo, Japan
[7] Kurashiki Cent Hosp, Kurashiki, Okayama, Japan
[8] Shonan Kamakura Gen Hosp, Kamakura, Kanagawa, Japan
[9] Teikyo Univ Hosp, Tokyo, Japan
[10] 17 Yamada Hirao Cho,Nishikyo Ku, Kyoto 6158256, Japan
关键词
Paclitaxel-coated balloon; Small vessel disease; Native coronary artery; Balloon angioplasty; SMALL CORONARY-ARTERIES; DRUG-ELUTING BALLOON; LUMEN ENLARGEMENT; STENT RESTENOSIS; CATHETER; TRIAL; PLACEMENT; REGISTRY; LESIONS; BELLO;
D O I
10.1007/s00392-017-1126-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim We investigated the efficacy and safety of using paclitaxel-coated balloon (PCB) to treat small vessel disease. Methods and results In this multicenter, prospective, randomized controlled trial, one-hundred and thirty-five patients with native coronary lesions in small vessels were randomized into a PCB group and plain balloon angioplasty (POBA) group at a ratio of 2:1. There were no differences in target vessel failure (TVF) that was defined as cardiac death or target vessel-related myocardial infarction or target lesion revascularization (TLR), between the two groups (3.4 vs. 10.3%; P = 0.20), and TLR was slightly lower in the PCB group (2.3%) than that in the POBA group (10.3%) during 24 weeks follow-up. The late lumen loss (LLL) was significantly lower in the PCB group (0.01 +/- 0.31 vs. 0.32 +/- 0.34 mm; P < 0.01) and late lumen enlargement (LLE) was more frequently observed in the PCB group (48 vs. 15%; P < 0.01) by angiographic follow-up after 24 weeks. There were no cases of death, myocardial infarction, thrombosis and reocclusion in either group. Conclusions This study was not able to demonstrate superiority of PCB compared with POBA.
引用
收藏
页码:824 / 832
页数:9
相关论文
共 50 条
  • [1] A multicenter randomized comparison of paclitaxel-coated balloon with plain balloon angioplasty in patients with small vessel disease
    Atsushi Funatsu
    Shigeru Nakamura
    Naoto Inoue
    Shinsuke Nanto
    Masato Nakamura
    Masashi Iwabuchi
    Kenji Ando
    Ryuta Asano
    Seiji Habara
    Shigeru Saito
    Ken kozuma
    Kazuaki Mitsudo
    Clinical Research in Cardiology, 2017, 106 : 824 - 832
  • [2] Comparison of Paclitaxel-Coated Balloon Treatment and Plain Old Balloon Angioplasty for De Novo Coronary Lesions
    Her, Ae-Young
    Ann, Soe Hee
    Singh, Gillian Balbir
    Kim, Yong Hoon
    Yoo, Sang-Yong
    Garg, Scot
    Koo, Bon-Kwon
    Shin, Eun-Seok
    YONSEI MEDICAL JOURNAL, 2016, 57 (02) : 337 - 341
  • [3] Multicenter, Randomized Trial of Conventional Balloon Angioplasty versus Paclitaxel-Coated Balloon Angioplasty for the Treatment of Dysfunctioning Autologous Dialysis Fistulae
    Maleux, Geert
    Mijnsbrugge, Ward Vander
    Henroteaux, Denis
    Laenen, Annouschka
    Cornelissen, Sandra
    Claes, Kathleen
    Fourneau, Inge
    Verbeeck, Nicolas
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 29 (04) : 470 - 475
  • [4] Paclitaxel-Coated Balloon versus Plain Balloon Angioplasty for Dysfunctional Autogenous Radiocephalic Arteriovenous Fistulas: A Prospective Randomized Controlled Trial
    Kim, Jong Woo
    Kim, Jeong Ho
    Byun, Sung Su
    Kang, Jin Mo
    Shin, Ji Hoon
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (11) : 1239 - 1247
  • [5] A novel constrained, paclitaxel-coated angioplasty balloon catheter
    Cremers, Bodo
    Binyamin, Gary
    Clever, Yvonne P.
    Seifert, Paul
    Konstantino, Eitan
    Kelsch, Bettina
    Bienek, Stephanie
    Speck, Ulrich
    Scheller, Bruno
    EUROINTERVENTION, 2017, 12 (17) : 2140 - 2147
  • [6] Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease
    Atsushi Funatsu
    Tomoko Kobayashi
    Masahiro Mizobuchi
    Shigeru Nakamura
    Cardiovascular Intervention and Therapeutics, 2019, 34 : 317 - 324
  • [7] Paclitaxel-Coated Balloon Angioplasty for Dysfunctional Arteriovenous Fistulas
    Tan, Ru Yu
    Tang, Tjun Yip
    Tan, Chieh Suai
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2022, 79 (01) : 129 - 130
  • [8] Safety of Paclitaxel-Coated Balloon Angioplasty for Femoropopliteal Peripheral Artery Disease
    Ouriel, Kenneth
    Adelman, Mark A.
    Rosenfield, Kenneth
    Scheinert, Dierk
    Brodmann, Marianne
    Pena, Constantino
    Geraghty, Patrick
    Lee, Arthur
    White, Roseann
    Clair, Daniel G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (24) : 2515 - 2524
  • [9] Clinical and angiographic outcomes of coronary dissection after paclitaxel-coated balloon angioplasty for small vessel coronary artery disease
    Funatsu, Atsushi
    Kobayashi, Tomoko
    Mizobuchi, Masahiro
    Nakamura, Shigeru
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2019, 34 (04) : 317 - 324
  • [10] Efficacy and Safety of Paclitaxel-Coated Balloon Angioplasty for Dysfunctional Arteriovenous Fistulas: A Multicenter Randomized Controlled Trial
    Yin, Yanqi
    Shi, Yaxue
    Cui, Tianlei
    Li, Hua
    Chen, Jianghua
    Zhang, Lihong
    Yu, Zhengya
    Li, Hong
    Yan, Yan
    Wu, Kun
    Jin, Qizhuang
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2021, 78 (01) : 19 - +