Evaluation of R404a single loop thermosyphon for shaft cooling in motorized spindle

被引:22
|
作者
Li, Fajing
Gao, Jianmin
Shi, Xiaojun [1 ]
Xu, Liang
Zhu, Ke
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Single loop thermosyphon; Shaft cooling; Zeotropic mixed refrigerant; SOLAR WATER-HEATER;
D O I
10.1016/j.applthermaleng.2018.06.072
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, a single loop thermosyphon charged with refrigerant R404a was investigated for shaft cooling in a motorized spindle. Tests were performed for a heating power range of 20-200 W, evaporation temperatures between 20 degrees C and 72 degrees C, and filling ratio (FR) of 30-80%. Effects of zeotropic mixed refrigerant R404a on heat transfer performance and optimal FR were analyzed and compared with those of pure refrigerants R134a and R600a. Results indicated that R404a single loop thermosyphon has a higher heat transfer efficiency and smaller thermal resistance than those charged with R134a and R600a when the temperature of evaporation is below 57 degrees C. Due to changes in R404a components during the injection process, the minimum average thermal resistance of R404a single loop thermosyphon (0.41 degrees C/W) appears at 50% < FR < 60%, compared to 30% < FR < 50% for pure refrigerant.
引用
收藏
页码:262 / 268
页数:7
相关论文
共 36 条
  • [1] Experimental investigation of single loop thermosyphons utilized in motorized spindle shaft cooling
    Li, Fajing
    Gao, Jianmin
    Shi, Xiaojun
    Liang, Feng
    Zhu, Ke
    APPLIED THERMAL ENGINEERING, 2018, 134 : 229 - 237
  • [2] Experimental investigation on the start-up characteristics of single loop thermosyphon for motorized spindle bearing-shaft system cooling
    Shi, Xiaojun
    Mu, Yingjie
    Chen, Gangqing
    Zhang, Xiaodong
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 120
  • [3] Investigation on Heat Transfer Performance of Loop Thermosyphon for Inner Cooling of Motorized Spindle
    Li F.
    Gao J.
    Shi X.
    Liang F.
    Tang R.
    Shi, Xiaojun, 2017, Xi'an Jiaotong University (51): : 90 - 97
  • [4] Visualization research on a pentane loop thermosyphon for shaft cooling
    Li, Fajing
    Gao, Jianmin
    Shi, Xiaojun
    Wang, Zhifeng
    Wang, Daoyong
    Lin, Zeqin
    HEAT AND MASS TRANSFER, 2022, 58 (03) : 489 - 498
  • [5] Visualization research on a pentane loop thermosyphon for shaft cooling
    Fajing Li
    Jianmin Gao
    Xiaojun Shi
    Zhifeng Wang
    Daoyong Wang
    Zeqin Lin
    Heat and Mass Transfer, 2022, 58 : 489 - 498
  • [6] CFD modelling of a two-phase closed thermosyphon charged with R134a and R404a
    Fadhl, Bandar
    Wrobel, Luiz C.
    Jouhara, Hussam
    APPLIED THERMAL ENGINEERING, 2015, 78 : 482 - 490
  • [7] Experimental investigation of an R600a two-phase loop thermosiphon to cool a motorized spindle shaft
    Li, Fajing
    Gao, Jianmin
    Shi, Xiaojun
    Liang, Feng
    Zhu, Ke
    Li, Yunlong
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2018, 97 : 9 - 16
  • [8] Adsorption characteristics evaluation of R134A and R404A on different adsorbents
    Kilic, M.
    Gonul, E.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 : 306 - 311
  • [9] Dynamic Heat Transfer on Skin Phantom Exposed to R404A Pulsed Spray Cooling
    Yang Ran
    Zhu Xingang
    Yang Tao
    Zhou Zhifu
    Chen Bin
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (05):
  • [10] Dynamic Heat Transfer on Skin Phantom Exposed to R404A Pulsed Spray Cooling
    Yang R.
    Zhu X.
    Yang T.
    Zhou Z.
    Chen B.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2022, 49 (05):