Comfort Analysis for the building at a Metro Depot

被引:0
|
作者
Duan Jin [1 ]
Li Yun-gui [1 ]
机构
[1] China State Construct Tech Ctr, Beijing 101300, Peoples R China
关键词
vibration; comfort analysis; metro depot; FEA;
D O I
10.4028/www.scientific.net/AMM.638-640.1666
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A comfort analysis for the buildingat a metro depot is presented in this paper with FEA method. First, the dynamic analysis for the whole building structure is performed and the acceleration responseofeach floor is calculated and compared with the civil codes, based on which the structuralcomfortis estimated. And then, the major factor resulting in the comfort problem of shear-wall buildings is obtained by frequency domain analysis and it is the summation of mode participating coefficients according to the peak-amplitude frequency-range of vibration source. And finally, an advice for the modification of building design is presented to avoid the structural comfort problem.
引用
收藏
页码:1666 / 1671
页数:6
相关论文
共 50 条
  • [1] Measurement and analysis of vibrations in a residential building constructed on an elevated metro depot
    Cao, Zhiliang
    Guo, Tong
    Zhang, Zhiqiang
    Li, Aiqun
    [J]. MEASUREMENT, 2018, 125 : 394 - 405
  • [2] Evaluation and Analysis Model of Stray Current in the Metro Depot
    Lin, Sheng
    Huangfu, Yang
    Zhou, Qi
    Wang, Aimin
    [J]. IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2021, 7 (03): : 1780 - 1794
  • [3] Measurement of ground and nearby building vibration and noise induced by trains in a metro depot
    Zou, Chao
    Wang, Yimin
    Wang, Peng
    Guo, Jixing
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2015, 536 : 761 - 773
  • [4] Experimental Study and Numerical Analysis of Sihui Metro Depot and the Superstructure
    Zhang, Jing
    Zhang, Bin
    Liu, Ying Hua
    Wang, Long Qi
    Bin Wu, Yu
    [J]. VIBRATION, STRUCTURAL ENGINEERING AND MEASUREMENT II, PTS 1-3, 2012, 226-228 : 176 - +
  • [5] Experiment and analysis of train-induced metro depot vibration
    Chen, Zhaowei
    Peng, Song
    Xu, Hong
    Yin, Qiang
    Zhou, Jianting
    [J]. INTERNATIONAL JOURNAL OF RAIL TRANSPORTATION, 2024,
  • [6] Vibration characteristics of metro depot upper building under double vibration source excitation
    Feng, Qing-Song
    Wang, Zi-Yu
    Liu, Quan-Min
    Luo, Xin-Wei
    Li, Ji-Yang
    [J]. Jiaotong Yunshu Gongcheng Xuebao/Journal of Traffic and Transportation Engineering, 2019, 19 (04): : 59 - 69
  • [7] Comparative analysis of environmental vibration characteristics in different regions of a metro depot
    Feng, Qingsong
    Wang, Ziyu
    Liu, Quanmin
    Luo, Xinwei
    Luo, Kun
    Li, Jiyang
    [J]. Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (14): : 179 - 185
  • [8] Design of rainwater drainage for Harbin metro depot of line 1 of Harbin metro
    [J]. Wang, L.-C., 1600, Editorial Department of Journal of Railway Engineering Society, China (30):
  • [9] Impedance Model of Train-Induced Vibration Transmission Across a Transfer Structure into an Overtrack Building in a Metro Depot
    Zou, Chao
    Moore, James A.
    Sanayei, Masoud
    Tao, Ziyu
    Wang, Yimin
    [J]. JOURNAL OF STRUCTURAL ENGINEERING, 2022, 148 (11)
  • [10] COMFORT, CLIMATE ANALYSIS AND BUILDING DESIGN GUIDELINES
    GIVONI, B