Reflective Type Liquid Refractometer Based on Multiple Total Internal Reflections and Attenuated Total Reflections in Heterodyne Interferometry

被引:0
|
作者
Wang, Shinn-Fwu [1 ]
Huang, Chun-Wei [1 ]
Liu, Che-Yu [1 ]
Lai, Wesley [1 ]
Hsieh, Meng-Feng [1 ]
Chung, Hung-Chen [1 ]
Chiu, Jyh-Shyan [1 ]
Liao, Yun Hsiang [1 ]
Yeh, Rih-Huei [2 ]
机构
[1] Ching Yun Univ, Dept Elect Engn, Jhongli, Taoyuan County, Taiwan
[2] Ching Yun Univ, Inst Comp Commun & Syst Engn, Jhongli, Taoyuan County, Taiwan
关键词
liquid refractometer; multiple attenuated total-internal reflections (MATRs); multiple total-internal reflections (MTIRs); heterodyne interferometry (HI); surface plasmon resonance (SPR); Kretchmann's configuration; SURFACE; SENSOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a reflective type liquid refractometer based on multiple attenuated total reflections and total internal reflections in heterodyne interferometry is proposed. The liquid refractometer is designed as a reflective elongated prism that is made of BK7 glass. The shorter-side surface of the reflective elongated prism was coated with 2nm Ti-film and 45.5nm Aufilm, but the longer-side surface of that was not coated with metal films. With the new type liquid refractometer, the refractive index for the tested medium can be obtained only by measuring the phase difference between the p-and s-polarization lights due to the multiple attenuated total reflections and total internal reflections effects. Its resolution can reach 1 10(-6) refractive index unit (RIU). The reflective type liquid refractometer has some merits, e. g., high resolution, high sensitivity, stability, and in real-time test, etc.
引用
下载
收藏
页数:4
相关论文
共 50 条
  • [1] New Type Liquid Refractometer Based on Multiple Total-Internal Reflections in Heterodyne Interferometry
    Wang, Shinn-Fwu
    Hsu, Cheng-Lung
    Lin, Chih-Ju
    Huang, Chun-Wei
    Hsieh, Chin-Hsiang
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 683 - 686
  • [2] New-Type Biosensor Based on Multiple Total-Internal Reflections in Heterodyne Interferometry
    Wang, Shinn-fwu
    Hsieh, Chin-hsiang
    Chu, Yi
    Liao, Yu-pin
    Lay, Shyh-rong
    Kao, Fu-hsi
    Liu, An-li
    MATERIALS SCIENCE, MACHINERY AND ENERGY ENGINEERING, 2014, 853 : 260 - 263
  • [3] Optical fiber biosensor based on multiple total internal reflections in heterodyne interferometry
    Wang, Shinn-Fwu
    Chiu, Jyh-Shyan
    Wang, Ming-Jen
    INTERNATIONAL CONFERENCE ON SMART MATERIALS AND NANOTECHNOLOGY IN ENGINEERING, PTS 1-3, 2007, 6423
  • [4] Small-displacement sensing system based on multiple total internal reflections in heterodyne interferometry
    Wang, Shinn-Fwu
    Chiu, Ming-Hung
    Chen, Wei-Wu
    Kao, Fu-Hsi
    Chang, Rong-Seng
    APPLIED OPTICS, 2009, 48 (13) : 2566 - 2573
  • [5] Instrument for measuring small angles by use of multiple total internal reflections in heterodyne interferometry
    Chiu, MH
    Wang, SF
    Chang, RS
    APPLIED OPTICS, 2004, 43 (29) : 5438 - 5442
  • [6] U-shaped optical fiber sensor based on multiple total internal reflections in heterodyne interferometry
    Wang, Shinn-Fwu
    OPTICS AND LASERS IN ENGINEERING, 2009, 47 (10) : 1039 - 1043
  • [7] D-type fiber optic sensor used as a refractometer based on total-internal reflection heterodyne interferometry
    Chiu, MH
    Hsu, SN
    Yang, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 101 (03) : 322 - 327
  • [8] ANALYTIC DETERMINATIONS VIA ATTENUATED TOTAL REFLECTIONS
    ESCOLAR, D
    GIL, M
    ANALES DE QUIMICA, 1976, 72 (03): : 206 - 212
  • [9] Small displacement measurements based on total-internal-reflection heterodyne interferometry
    Chiu, MH
    Lin, JY
    Su, DC
    THREE-DIMENSIONAL IMAGING, OPTICAL METROLOGY, AND INSPECTION V, 1999, 3835 : 32 - 38
  • [10] Measurement of small wavelength shifts based on total internal reflection heterodyne interferometry
    Hsieh, Meng-Chang
    Lin, Jiun-You
    Chang, Chia-Ou
    CHINESE OPTICS LETTERS, 2016, 14 (08)