The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than 100 C, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.
引用
收藏
页码:103 / 108
页数:6
相关论文
共 28 条
  • [1] Continuous on-line partial discharge monitoring of power generators
    Kheirmand, A
    Leijon, M
    [J]. IEEE 1996 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I & II, 1996, : 496 - 499
  • [2] Novel Inductive Sensor Solutions for On-line Partial Discharge and Power Quality Monitoring
    Siddiqui, Bashir Ahmed
    Pakonen, Pertti
    Verho, Pekka
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 209 - 216
  • [3] Rogowski air coil sensor technique for on-line partial discharge measurement of power cables
    Zhang, Z. S.
    Xiao, D. M.
    Li, Y.
    [J]. IET SCIENCE MEASUREMENT & TECHNOLOGY, 2009, 3 (03) : 187 - 196
  • [4] Assessment of the 6.6kV class on-line partial discharge measuring ceramic coupling sensor for winding machines
    Kang, DS
    Han, MK
    Kim, YJ
    Yun, YH
    [J]. Proceedings of the 2005 International Symposium on Electrical Insulating Materials, Vols, 1-3, 2005, : 873 - 876
  • [5] Reliability of steam pipelines of thermal power plants in the course of long-term operation
    Balyts'kyi, O. I.
    Ripei, I. V.
    Protsakh, Kh. A.
    [J]. MATERIALS SCIENCE, 2006, 42 (04) : 461 - 465
  • [6] Reliability of steam pipelines of thermal power plants in the course of long-term operation
    O. I. Balyts’kyi
    I. V. Ripei
    Kh. A. Protsakh
    [J]. Materials Science, 2006, 42 : 461 - 465
  • [7] On-line neural network based long-term voltage stability assessment of power system
    Repo, S
    Bastman, J
    Järventausta, P
    [J]. ENGINEERING INTELLIGENT SYSTEMS FOR ELECTRICAL ENGINEERING AND COMMUNICATIONS, 2002, 10 (01): : 9 - 17
  • [8] Long-term dimensional stability of a line scale made of low thermal expansion ceramic NEXCERA
    Takahashi, Akira
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (03)
  • [9] An on-line reconfigurable classification algorithm improves the long-term stability of gas sensor arrays in case of faulty and drifting sensors
    Magna, G.
    Mosciano, F.
    Martinelli, E.
    Di Natale, C.
    [J]. EUROSENSORS 2015, 2015, 120 : 249 - 252
  • [10] Recursive On-Line (2D)2PCA and Its Application to Long-Term Background Subtraction
    Seo, Ja-Won
    Kim, Seong Dae
    [J]. IEEE TRANSACTIONS ON MULTIMEDIA, 2014, 16 (08) : 2333 - 2344