System for photomultiplier tubes characterization and data acquisition for Water Cherenkov Detectors

被引:0
|
作者
Rosales, Mauro J. Bonilla [1 ]
Carrasco, Esperanza [1 ]
Torres, Ibrahim [1 ]
Moreno, Eduardo [2 ]
Carraminana, Alberto [1 ]
机构
[1] Inst Nacl Astroffs Opt & Elect, Puebla, Mexico
[2] Benemerita Univ Autonoma Puebla, Puebla, Mexico
关键词
Water Cherenkov detector; high energy; gamma-rays; photomultiplier tubes;
D O I
10.1117/12.2056589
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
A water Cherenkov detector uses the emission of Cherenkov radiation for detecting the trace of secondary particles generated by extensive air shower cascades traversing a purified water tank. These are used for the detection of high energy gamma-rays. A fundamental component of the detectors consists of the photomultiplier tubes (PMTs) used for detection of the Cherenkov radiation that is produced by very high energy particles moving faster than the speed of of light in the medium. INAOE, being one of the leading institutions of HAWC, decided to develop a system to characterize the PMTs that includes measurement of dark current, linear response region determination, response to a photoelectron and hence the gain. This characterization is indispensable when several PMTs operate in an array of water Cherenkov detectors. The system was further developed to simultaneously acquire data of several phototubes, allowing also to measure coincidences. Additionally, the VME scalers modules will be used to monitor up to 32 phototubes. This system has been used to characterize the PMTs of the LAGO experiment and can be used in the future for any type of PMT system.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A photomultiplier tube model for the water Cherenkov detectors of LAGO
    Pena-Rodriguez, J.
    Hernandez-Barajas, S.
    Leon-Carreno, Y.
    Nunez, L. A.
    37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [2] Microcontroller based data acquisition system for silicon photomultiplier detectors
    Ryder, N. C.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [3] Multichannel Acquisition System with Photomultiplier Detectors
    Bohdanowicz, Michal
    Kasprowicz, Grzegorz
    PHOTONICS APPLICATIONS IN ASTRONOMY, COMMUNICATIONS, INDUSTRY, AND HIGH-ENERGY PHYSICS EXPERIMENTS 2009, 2009, 7502
  • [4] Characterization of the photomultiplier tubes for the scintillation detectors of GRANDProto35 experiment
    Wang, X.
    Qian, X-L
    Yu, Y-H
    Feng, C-F
    Martineau-Huynh, O.
    Zhang, Y.
    Gou, Q-B
    Liu, W.
    Feng, Y-L
    JOURNAL OF INSTRUMENTATION, 2021, 16 (04)
  • [5] Pulse shape Discrimination for Online Data Acquisition in Water Cherenkov Detectors Based on FPGA/SoC
    Ordonez, Luis G. Garcia
    Molina, Romina Soledad
    Argueta, Ivan Rene Morales
    Crespo, Maria Liz
    Cicuttin, Andres
    Carrato, Sergio
    Ramponi, Giovanni
    Figueroa, Hector Eduardo Perez
    Escobar, Maynor Giovanni Ballina
    37TH INTERNATIONAL COSMIC RAY CONFERENCE, ICRC2021, 2022,
  • [6] Characterization of PET Data Acquisition System with Compressed Sensing Detectors
    Chang, Chen-Ming
    Olcott, Peter D.
    Hong, Key Jo
    Grant, Alexander M.
    Lee, Brian J.
    Kim, Ealgoo
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] PHOTOMULTIPLIER TUBES FOR LOW LEVEL CERENKOV DETECTORS
    STRINDEHAG, O
    ARKIV FOR FYSIK, 1965, 30 (06): : 529 - +
  • [8] Future Water Cherenkov Detectors
    Bergevin, Marc
    NUINT12: 8TH INTERNATIONAL WORKSHOP ON NEUTRINO-NUCLEUS INTERACTIONS IN THE FEW-GEV REGION, 2015, 1663
  • [9] Data analysis for solar neutrinos observed by water Cherenkov detectors⋆
    Yusuke Koshio
    The European Physical Journal A, 2016, 52
  • [10] Data analysis for solar neutrinos observed by water Cherenkov detectors
    Koshio, Yusuke
    EUROPEAN PHYSICAL JOURNAL A, 2016, 52 (04):