Comparison of Pericardial Patch Graft Thickness for Glaucoma Implant, Using Anterior Segment Optical Coherence Tomography

被引:0
|
作者
Kang, Min Gu [1 ]
Suh, Jae Shin [1 ]
Lee, Youn Gon [1 ]
Hwang, Young Hoon [1 ]
机构
[1] Konyang Univ, Coll Med, Kims Eye Hosp, Myung Gok Eye Res Inst, Seoul, South Korea
来源
关键词
Anterior segment optical coherence tomography; Glaucoma implant; Tube erosion; Pericardium patch graft; TUBE;
D O I
10.3341/jkos.2020.61.5.532
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the thickness of the processed pericardial patch graft for glaucoma implant tube coverage using anterior segment optical coherence tomography (AS-OCT). Methods: Thicknesses of seven samples of two pericardial patch grafts (Tutoplast pericardium, IOP Inc, Costa Mesa, CA, USA; pericardium LYO, DCI Donor Services, Inc., Nashville, TN, USA) were measured using AS-OCT (CASIA2, Tomey Corporation, Nagoya, Japan). The thickness of each sample was measured at the center and eight points with 45-degree angular distance, 2 mm from the center. The thickness was measured using AS-OCT program tools. Results: The median thicknesses were 219 mu m for Tutoplast pericardium and 157 mu m for pericardium LYO. Tutoplast pericardium was significantly thicker than pericardium LYO (p = 0.001); pericardium LYO had a wider interquartile range within each sample, compared to Tutoplast pericardium (p = 0.017). Conclusions: The thickness of the Tutoplast pericardium was greater and less variable than that of the pericardium LYO. These findings should be considered when choosing processed pericardium for coverage of glaucoma implants.
引用
收藏
页码:532 / 537
页数:6
相关论文
共 50 条
  • [1] Changes in Corneal Thickness in Congenital Glaucoma, Using Anterior Segment Optical Coherence Tomography
    Lee, Chaeyeon
    Lee, Eun Jung
    Jang, Yoonkyung
    Han, Jong Chul
    Kee, Chang Won
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2022, 63 (08): : 692 - 699
  • [2] Anterior segment optical coherence tomography in glaucoma
    Mueller, M.
    Geerling, G.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2008, 225 (03) : 194 - 199
  • [3] The use of anterior segment optical coherence tomography in glaucoma rainage implant surgery
    Au, Leon
    Fenerty, Cecilia
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2008, 39 (02) : 164 - 166
  • [4] Glaucoma Implant Tube Lumen Obstruction Visualized Using Anterior Segment Optical Coherence Tomography
    Nakakura, Shunsuke
    Noguchi, Asuka
    Noguchi, Santaro
    Hirose, Yuka
    Niimi, Koji
    Tabuchi, Hitoshi
    Kiuchi, Yoshiaki
    [J]. JOURNAL OF GLAUCOMA, 2018, 27 (03) : E64 - E67
  • [5] Detection of Glaucoma Using Anterior Segment Optical Coherence Tomography Images
    Priyanka, P.
    Juliet, V. Norris
    Devi, S. Shenbaga
    [J]. COMPUTER AIDED INTERVENTION AND DIAGNOSTICS IN CLINICAL AND MEDICAL IMAGES, 2019, 31 : 293 - 301
  • [6] The Role of Anterior Segment Optical Coherence Tomography in Glaucoma
    Salim, Sarwat
    [J]. JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [7] Application of anterior segment optical coherence tomography in glaucoma
    Sharma, Reetika
    Sharma, Ajay
    Arora, Tarun
    Sharma, Sourabh
    Sobti, Amit
    Jha, Bhaskar
    Chaturvedi, Neha
    Dada, Tanuj
    [J]. SURVEY OF OPHTHALMOLOGY, 2014, 59 (03) : 311 - 327
  • [8] Visualization of Blebs Using Anterior-Segment Optical Coherence Tomography after Glaucoma Drainage Implant Surgery
    Jung, Kyoung In
    Lim, Sung A.
    Park, Hae-Young L.
    Park, Chan Kee
    [J]. OPHTHALMOLOGY, 2013, 120 (05) : 978 - 983
  • [9] Evaluation of drainage implant tube position by anterior segment optical coherence tomography in pediatric glaucoma
    Yamada, Veronica Haysa
    de Moura, Christiane Rolim
    Allemann, Norma
    Reboucas-Santos, Vespasiano
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] New developments in anterior segment optical coherence tomography for glaucoma
    Wang, Dajiang
    Lin, Shan
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (02) : 111 - 117