Predicting deliverability of volumetric-modulated arc therapy (VMAT) plans using aperture complexity analysis

被引:62
|
作者
Younge, Kelly C. [1 ]
Roberts, Don [1 ]
Janes, Lindsay A. [1 ]
Anderson, Carlos [1 ]
Moran, Jean M. [1 ]
Matuszak, Martha M. [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, 1500 East Med Ctr Dr, Ann Arbor, MI 48109 USA
来源
关键词
VMAT; optimization; complexity metric; patient-specific QA; IMRT;
D O I
10.1120/jacmp.v17i4.6241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to evaluate the ability of an aperture complexity metric for volumetric-modulated arc therapy (VMAT) plans to predict plan delivery accuracy. We developed a complexity analysis tool as a plug-in script to Varian's Eclipse treatment planning system. This script reports the modulation of plans, arcs, and individual control points for VMAT plans using a previously developed complexity metric. The calculated complexities are compared to that of 649 VMAT plans previously treated at our institution from 2013 to mid-2015. We used the VMAT quality assurance (QA) results from the 649 treated plans, plus 62 plans that failed pretreatment QA, to validate the ability of the complexity metric to predict plan deliverability. We used a receiver operating characteristic (ROC) analysis to determine an appropriate complexity threshold value above which a plan should be considered for reoptimization before it moves further through our planning workflow. The average complexity metric for the 649 treated plans analyzed with the script was 0.132 mm(-1) with a standard deviation of 0.036 mm(-1). We found that when using a threshold complexity value of 0.180 mm-1, the true positive rate for correctly identifying plans that failed QA was 44%, and the false-positive rate was 7%. Used clinically with this threshold, the script can identify overly modulated plans and thus prevent a significant portion of QA failures. Reducing VMAT plan complexity has a number of important clinical benefits, including improving plan deliverability and reducing treatment time. Use of the complexity metric during both the planning and QA processes can reduce the number of QA failures and improve the quality of VMAT plans used for treatment.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [1] Robustness of Volumetric-Modulated Arc Therapy (VMAT) Plans to Systematic MLC Positional Errors
    Qi, P.
    Xia, P.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 318 - 318
  • [2] Multidimensional correlation among plan complexity, quality and deliverability parameters for volumetric-modulated arc therapy using canonical correlation analysis
    Shen, Lanxiao
    Chen, Shan
    Zhu, Xiaoyang
    Han, Ce
    Zheng, Xiaomin
    Deng, Zhenxiang
    Zhou, Yongqiang
    Gong, Changfei
    Xie, Congying
    Jin, Xiance
    [J]. JOURNAL OF RADIATION RESEARCH, 2018, 59 (02) : 207 - 215
  • [3] Impact of Collimator Angle on Deliverability of Volumetric Modulated Arc Therapy (VMAT)
    Hong, D.
    Bundalevski, I.
    Wong, K.
    Mokhtar, B. E.
    Ashamalla, H.
    Parameritis, J.
    Kyriacou, A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E632 - E632
  • [4] Automated Complexity Analysis of Volumetric Modulated Arc Therapy Plans
    Younge, K. C.
    Matuszak, M. M.
    Janes, L. A.
    Anderson, C. J. R.
    Moran, J. M.
    Roberts, D. A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3704 - 3704
  • [5] Simultaneous delivery time and aperture shape optimization for the volumetric-modulated arc therapy (VMAT) treatment planning problem
    Mahnam, Mehdi
    Gendreau, Michel
    Lahrichi, Nadia
    Rousseau, Louis-Martin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14): : 5589 - 5611
  • [6] Retrospective analysis of portal dosimetry pre-treatment quality assurance of prostate volumetric-modulated arc therapy (VMAT) plans
    Maraghechi, Borna
    Davis, Jack
    Badu, Shyam
    Fleck, Andre
    Darko, Johnson
    Osei, Ernest
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 44 - 52
  • [7] Analysis of a volumetric-modulated arc therapy (VMAT) single phase prostate template as a class solution
    Hoffmann, Matthew
    Pacey, Jacqueline
    Goodworth, Josie
    Laszcyzk, Andrea
    Ford, Richard
    Chick, Brendon
    Greenham, Stuart
    Westhuyzen, Justin
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (01) : 92 - 96
  • [8] The determination of optimal treatment plans for Volumetric Modulated Arc Therapy (VMAT)
    Dursun, Pinar
    Taskin, Z. Caner
    Altinel, I. Kuban
    [J]. EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2019, 272 (01) : 372 - 388
  • [9] A Prediction Model for Pretreatment Dose Verification of Volumetric-Modulated Arc Therapy (VMAT) Using Machine Learning
    Li, G.
    Yuan, Q.
    Bai, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E612 - E612
  • [10] An Aperture Preserved Approach for Adaptive Radiotherapy of Prostate Cancer Using Volumetric-Modulated Arc Therapy
    Price, A.
    Dooley, J.
    Zhu, T.
    Pappafotis, R.
    Wang, A.
    Chen, R.
    Das, S.
    Lian, J.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3007 - 3007