Quantitative reconstruction of PIXE-tomography data for thin samples using GUPIX X-ray emission yields

被引:12
|
作者
Michelet, C. [1 ,2 ]
Barberet, Ph [1 ,2 ]
Deves, G. [1 ,2 ]
Bouguelmouna, B. [1 ,2 ]
Bourret, S. [1 ,2 ]
Delville, M. -H. [3 ]
Le Trequesser, Q. [1 ,2 ,3 ]
Gordillo, N. [1 ,2 ]
Beasley, D. G. [4 ]
Marques, A. C. [5 ]
Farau, R. [1 ,2 ]
Toko, B. R. [1 ,2 ]
Campbell, J. [6 ]
Maxwell, J. [6 ]
Motetto, Ph [1 ,2 ]
Seznec, H. [1 ,2 ]
机构
[1] Univ Bordeaux, CENBG, UMR 5797, F-33170 Gradignan, France
[2] CNRS, IN2P3, CENBG, UMR 5797, F-33170 Gradignan, France
[3] Univ Bordeaux, ICMCB, UPR9048, CNRS, F-33608 Pessac, France
[4] UCL, Dept Med Phys & Bioengn, CMIC, London WC1E 6BT, England
[5] Univ Lisbon, IST IPFN, P-2685066 Bobadela Lrs, Portugal
[6] Univ Guelph, Guelph Waterloo Phys Inst, Guelph, ON N1G 2W1, Canada
关键词
PIXE tomography; Filtered backprojection; MLEM; ImageJ; Caenorhabditis elegans; TRANSMISSION ION MICROSCOPY; SOFTWARE PACKAGE; BEAM; MICROANALYSIS; ALGORITHM;
D O I
10.1016/j.nimb.2014.11.035
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present here a new development of the TomoRebuild software package, to perform quantitative Particle Induced X-ray Emission Tomography (PIXET) reconstruction. X-ray yields are obtained from the GUPIX code. The GUPIX data base is available for protons up to 5 MeV and also in the 20-100 MeV energy range, deuterons up to 6 MeV, He-3 and alphas up to 12 MeV. In this version, X-ray yields are calculated for thin samples, i.e. without simulating X-ray attenuation. PIXET data reconstruction is kept as long as possible independent from Scanning Transmission Ion Microscopy Tomography (STIMT). In this way, the local mass distribution (in g/cm(3)) of each X-ray emitting element is reconstructed in all voxels of the analyzed volume, only from PIXET data, without the need of associated STIMT data. Only the very last step of data analysis requires STIMT data, in order to normalize PIXET data to obtain concentration distributions, in terms of normalized mass fractions (in mu g/g). For this, a noise correction procedure has been designed in ImageJ. Moreover sinogram or image misalignment can be corrected, as well as the difference in beam size between the two experiments. The main features of the TomoRebuild code, user friendly design and modular C++ implementation, were kept. The software package is portable and can run on Windows and Linux operating systems. An optional user-friendly graphic interface was designed in Java, as a plugin for the ImageJ graphic software package. Reconstruction example'S are presented from biological specimens of Caenorhabditis elegans - a small nematode constituting a reference model for biology studies. The reconstruction results are compared between the different codes TomoRebuild, DISRA and JPDCET, and different reconstruction methods: Filtered BackProjection (FBP) and Maximum Likelihood Expectation Maximization (MLEM). (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
  • [1] Quantitative reconstruction of PIXE-tomography data for thin samples using GUPIX X-ray emission yields
    Univ. Bordeaux, CENBG, UMR 5797, Gradignan
    F-33170, France
    不详
    F-33170, France
    不详
    F-33608, France
    不详
    WC1E 6BT, United Kingdom
    不详
    2685-066, Portugal
    不详
    ON
    N1G 2W1, Canada
    Nucl Instrum Methods Phys Res Sect B, (92-99):
  • [2] A comparison of quantitative reconstruction techniques for PIXE-tomography analysis applied to biological samples
    Beasley, D. G.
    Alves, L. C.
    Barberet, Ph.
    Bourret, S.
    Deves, G.
    Gordillo, N.
    Michelet, C.
    Le Trequesser, Q.
    Marques, A. C.
    Seznec, H.
    da Silva, R. C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 331 : 248 - 252
  • [3] Quantitative Reconstruction of Polychromatic X-ray Fluorescence Computed Tomography Using Transmission Tomography
    Gao, Bo
    Laforce, Brecht
    Vincze, Laszlo
    Van Hoorebeke, Luc
    Boone, Matthieu N.
    ANALYTICAL CHEMISTRY, 2021, 93 (04) : 2082 - 2089
  • [4] Polychromatic X-ray tomography: direct quantitative phase reconstruction
    Arhatari, Benedicta D.
    van Riessen, Grant
    Peele, Andrew
    OPTICS EXPRESS, 2012, 20 (21): : 23361 - 23366
  • [6] Elemental analysis of agricultural soil samples by particle induced X-ray emission (PIXE) technique
    Cruvinel, PE
    Flocchini, RG
    Artaxo, P
    Crestana, S
    Herrmann, PSP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1999, 150 (1-4): : 478 - 483
  • [7] Quantitative determination of heterogeneity in samples of rock type plug using X-ray computerized tomography
    Mendieta-Penagos, Alejandro
    Reinaldo Rincon-Bautista, Luis
    Herrera-Otero, Edwar
    BOLETIN DE GEOLOGIA, 2019, 41 (01): : 133 - 149
  • [8] Light elements quantitative x-ray microanalysis of thin samples in STEM. Absorption correction using EELS data
    Banchet, V
    Michel, J
    Jallot, E
    Laurent-Maquin, D
    Balossier, G
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (13) : 1599 - 1604
  • [9] Quantitative Object Reconstruction Using Abel Transform X-Ray Tomography and Mixed Variable Optimization
    Abramson, Mark A.
    Asaki, Thomas J.
    Dennis, J. E., Jr.
    O'Reilly, Kevin R.
    Pingel, Rachael L.
    SIAM JOURNAL ON IMAGING SCIENCES, 2008, 1 (03): : 322 - 342
  • [10] Investigation of IC samples using X-ray computer tomography
    Bord, S
    Clement, A
    Lecomte, JC
    Marmeggi, JC
    JOURNAL DE PHYSIQUE IV, 2004, 118 : 413 - 417