Cerebral arterial gas embolism in a diver using closed-circuit rebreather diving apparatus

被引:0
|
作者
Chong, Si Jack [1 ]
Tan, Teck Wei [1 ]
机构
[1] Royal Singapore Navy Med Serv, Med Doctrine & Training Branch, Singapore, Singapore
关键词
cerebral arterial gas embolism (CAGE); closed-circuit underwater breathing system; recompression therapy;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
A Singaporean naval diver suffered symptoms and signs of cerebral arterial gas embolism (CAGE) following a panicked ascent from a depth of 5-6 metres' sea water while using a Drager LAR V closed-circuit oxygen rebreather system. He presented with altered mental status and paresis. CAGE due to gas mixtures with high oxygen content has seldom been reported. The diver had no sequelae following prompt recompression therapy. This positive clinical outcome may be attributable to the high oxygen content in the diver's inspired gas and/or the promptness of recompression.
引用
收藏
页码:46 / 48
页数:3
相关论文
共 50 条
  • [1] Arterial gas embolism in a diver using a closed-circuit oxygen rebreathing diving apparatus
    Carstairs, S
    [J]. UNDERSEA & HYPERBARIC MEDICINE, 2001, 28 (04): : 229 - 231
  • [2] Performance of cartridge and granular carbon dioxide absorbents in a closed-circuit diving rebreather
    Gant, Nicholas
    van Waart, Hanna
    Ashworth, Edward T.
    Mesley, Peter
    Mitchell, Simon J.
    [J]. DIVING AND HYPERBARIC MEDICINE, 2019, 49 (04) : 298 - 303
  • [3] A Closed-Circuit Rebreather for the Characterization of Denitrogenation
    Hugon, Julien
    Rostain, Jean-Claude
    Gardette, Bernard
    [J]. AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2010, 81 (11): : 1018 - 1023
  • [4] The duration of two carbon dioxide absorbents in a closed-circuit rebreather diving system
    Harvey, David
    Pollock, Neal W.
    Gant, Nicholas
    Hart, Jason
    Mesley, Peter
    Mitchell, Simon J.
    [J]. DIVING AND HYPERBARIC MEDICINE, 2016, 46 (02) : 92 - 97
  • [5] Diver respiratory responses to a tunable closed-circuit breathing apparatus
    Fothergill, DM
    Joye, DD
    Carlson, NA
    [J]. UNDERSEA & HYPERBARIC MEDICINE, 1997, 24 (02): : 91 - 105
  • [6] Hypoxia signatures in closed-circuit rebreather divers
    Popa, Daniel
    Kutz, Craig
    Carlile, Morgan
    Brett, Kaighley
    Moya, Esteban A.
    Powell, Frank
    Witucki, Peter
    Sadler, Richard
    Sadler, Charlotte
    [J]. DIVING AND HYPERBARIC MEDICINE, 2022, 52 (04) : 237 - 244
  • [7] Altitude Diving on a Closed Circuit Oxygen Rebreather
    Conard, Jonathan
    [J]. UNDERSEA AND HYPERBARIC MEDICINE, 2023, 50 (04) : 391 - 393
  • [8] Hyperoxic myopia in a closed-circuit mixed-gas scuba diver
    Butler, FK
    White, E
    Twa, M
    [J]. UNDERSEA & HYPERBARIC MEDICINE, 1999, 26 (01): : 41 - 45
  • [9] PULMONARY ATELECTASIS FORMATION DURING DIVING WITH CLOSED-CIRCUIT OXYGEN BREATHING APPARATUS
    DAHLBACK, GO
    BALLDIN, UI
    [J]. UNDERSEA BIOMEDICAL RESEARCH, 1985, 12 (02): : 129 - 137
  • [10] Closed-circuit oxygen diving in the US navy
    Butler, FK
    [J]. UNDERSEA & HYPERBARIC MEDICINE, 2004, 31 (01): : 3 - 20