Reconstructing the 3D Shape and Bone Mineral Density Distribution of the Proximal Femur From Dual-Energy X-Ray Absorptiometry

被引:61
|
作者
Whitmarsh, Tristan [1 ,2 ]
Humbert, Ludovic [1 ,2 ]
De Craene, Mathieu [1 ,2 ]
Del Rio Barquero, Luis M. [3 ]
Frangi, Alejandro F. [1 ,2 ]
机构
[1] Univ Pompeu Fabra UPF, Ctr Computat Imaging & Simulat Technol Biomed CIS, Informat & Commun Technol Dept, Barcelona 08002, Spain
[2] CIBER Bioengn Biomat & Nanomed CIBER BBN, Barcelona 08003, Spain
[3] CETIR Ctr Med, Barcelona 08003, Spain
关键词
Active appearance model; active shape model; deformable models; image reconstruction; image registration; QUANTITATIVE COMPUTED-TOMOGRAPHY; HIP FRACTURE; MODELS; CT; SEGMENTATION; REGISTRATION; CONSTRUCTION; GENERATION; STRENGTH; ATLAS;
D O I
10.1109/TMI.2011.2163074
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The accurate diagnosis of osteoporosis has gained increasing importance due to the aging of our society. Areal bone mineral density (BMD) measured by dual-energy X-ray absorptiometry (DXA) is an established criterion in the diagnosis of osteoporosis. This measure, however, is limited by its two-dimensionality. This work presents a method to reconstruct both the 3D bone shape and 3D BMD distribution of the proximal femur from a single DXA image used in clinical routine. A statistical model of the combined shape and BMD distribution is presented, together with a method for its construction from a set of quantitative computed tomography (QCT) scans. A reconstruction is acquired in an intensity based 3D-2D registration process whereby an instance of the model is found that maximizes the similarity between its projection and the DXA image. Reconstruction experiments were performed on the DXA images of 30 subjects, with a model constructed from a database of QCT scans of 85 subjects. The accuracy was evaluated by comparing the reconstructions with the same subject QCT scans. The method presented here can potentially improve the diagnosis of osteoporosis and fracture risk assessment from the low radiation dose and low cost DXA devices currently used in clinical routine.
引用
收藏
页码:2101 / 2114
页数:14
相关论文
共 50 条
  • [1] PREMENOPAUSAL AND POSTMENOPAUSAL CHANGES IN BONE-MINERAL DENSITY OF THE PROXIMAL FEMUR MEASURED BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    RAVN, P
    HETLAND, ML
    OVERGAARD, K
    CHRISTIANSEN, C
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1994, 9 (12) : 1975 - 1980
  • [2] A Long Femur Scan Field Does Not Alter Proximal Femur Bone Mineral Density Measurements by Dual-Energy X-Ray Absorptiometry
    McKiernan, Fergus Eoin
    Hocking, Jane
    Cournoyer, Susan
    Berg, Richard L.
    Linneman, James
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2011, 14 (03) : 354 - 358
  • [3] A reliable method for measuring proximal tibia and distal femur bone mineral density using dual-energy X-ray absorptiometry
    Bakkum, Arjan J. T.
    Janssen, Thomas W. J.
    Rolf, Marijn P.
    Roos, Jan C.
    Burcksen, Jos
    Knol, Dirk L.
    de Groot, Sonja
    [J]. MEDICAL ENGINEERING & PHYSICS, 2014, 36 (03) : 387 - 390
  • [4] Structural Parameters of Proximal Femur by 3D Dual-Energy X-ray Absorptiometry in Patients with Primary Hyperparathyroidism
    Garcia-Fontana, Beatriz
    Garcia-Martin, Antonia
    Marco, Luis Gracia
    Gonzalez-Salvatierra, Sheila
    Garcia-Fontana, Cristina
    Moratalla-Aranda, Enrique
    Becerra-Garcia, Diego
    Humbert, Ludovic
    Munoz-Torres, Manuel
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 : 242 - 242
  • [5] Dual-Energy X-Ray Absorptiometry: Beyond Bone Mineral Density Determination
    Choi, Yong Jun
    [J]. ENDOCRINOLOGY AND METABOLISM, 2016, 31 (01) : 25 - 30
  • [6] Hazards with evaluation of bone mineral density by dual-energy x-ray absorptiometry
    Bolosiu, CR
    [J]. OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S127 - S127
  • [7] The effect of hip rotation on bone mineral density of the proximal femur measured by dual energy X-ray absorptiometry
    Celik, Oezguer
    Salci, Yasar
    Manisali, Metin
    Korkusuz, Feza
    [J]. EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2009, 20 (02): : 71 - 77
  • [8] Volumetric bone mineral density derived from dual-energy X-ray absorptiometry measurements
    Braillon, PM
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (01) : 106 - 106
  • [9] Dual-energy X-ray absorptiometry - is it the gold standard, or is bone mineral density everything?
    Zuchowski, Pawel
    Jeka, Daniel
    [J]. REUMATOLOGIA, 2024, 62 (01): : 1 - 3
  • [10] The reliability of dual-energy X-ray absorptiometry measurements of bone mineral density in the metatarsals
    Joel T Fuller
    Jane Archer
    Jonathan D Buckley
    Margarita D Tsiros
    Dominic Thewlis
    [J]. Skeletal Radiology, 2016, 45 : 135 - 140