Development of a System for the Automatic Detection of Air Embolism Using a Precordial Doppler

被引:0
|
作者
Tedim, Ana [1 ]
Amorim, Pedro [2 ]
Castro, Ana [3 ]
机构
[1] Ctr Hosp Porto, Hosp Santo Antonio, Oporto, Portugal
[2] Ctr Hosp Porto, Hosp Santo Antonio, Inst Ciencias Biomed Abel Salazar, Oporto, Portugal
[3] Univ Porto, Fac Engn, P-4100 Oporto, Portugal
关键词
DIAGNOSIS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Venous air embolism (VAE) is the air bubble accumulation in the right side of the heart. Changes in Doppler heart sound (DHS) are characteristic of VAE, and the anesthesiologist has to pay attention to this event continuously, which may not always be possible. This work aims to study different features of the heart sound through a precordial Doppler, that may provide useful information on VAE episodes. A clinical protocol was designed, and DHS was collected at baseline and following infusions of saline with 4 distinct volumes (1ml, 5ml, 8ml and 10ml), and two infusion rates (slow and fast), given by central and peripheric catheters. Signal was pre-processed, the envelope of each signal was extracted, and five features were implemented and evaluated: frequency corresponding to 95% of Welch periodogram power (f95), frequency corresponding to 50% of Welch periodogram power (f50), frequency corresponding to maximum power spectral density (fm), entropy (E), and frequency corresponding to maximum energy of a wavelet transform (freqwav). Relation between extracted features and saline infusions were studied and compared to baseline values. A Graphical User Interface (GUI) with a database of Doppler heart sounds and annotations was also developed. Although features present a high variability between patients, E presents a better performance showing an increase in response to saline injections (in 75% injections), followed by f95 (62%), fm (56.3%), freqwav (37.5%) and f50 (0%).
引用
收藏
页码:2306 / 2309
页数:4
相关论文
共 50 条
  • [1] COMPARISON OF A TRANSESOPHAGEAL AND PRECORDIAL ULTRASONIC DOPPLER SENSOR IN THE DETECTION OF VENOUS AIR-EMBOLISM
    MUZZI, DA
    LOSASSO, TJ
    BLACK, S
    NISHIMURA, R
    ANESTHESIA AND ANALGESIA, 1990, 70 (01): : 103 - 104
  • [2] Precordial Doppler probe placement for optimal detection of venous air embolism during craniotomy
    Schubert, A
    Deogaonkar, A
    Drummond, JC
    ANESTHESIA AND ANALGESIA, 2006, 102 (05): : 1543 - 1547
  • [3] PRECORDIAL DOPPLER IS NOT OBSOLETE FOR VENOUS AIR-EMBOLISM MONITORING
    GIBBY, GL
    ANESTHESIOLOGY, 1988, 68 (05) : 829 - 829
  • [4] PRECORDIAL DOPPLER MONITORING AND PULSE OXIMETRY DURING CESAREAN DELIVERY - DETECTION OF VENOUS AIR-EMBOLISM
    VARTIKAR, JV
    JOHNSON, MD
    DATTA, S
    REGIONAL ANESTHESIA, 1989, 14 (03) : 145 - 148
  • [5] PRECORDIAL DOPPLER PROBE PLACEMENT FOR DETECTING VENOUS AIR-EMBOLISM REASSESSED
    CRAFT, RM
    WEGLINSKI, MR
    PERKINS, WJ
    LOSASSO, TJ
    ANESTHESIOLOGY, 1994, 81 (3A) : A230 - A230
  • [6] JUNCTIONAL RHYTHM CAN MIMIC AIR-EMBOLISM DURING PRECORDIAL DOPPLER MONITORING
    AZAD, SS
    MAGUIRE, D
    GOLDBERG, ME
    ANESTHESIA AND ANALGESIA, 1986, 65 (10): : 1083 - 1084
  • [7] PRECORDIAL DOPPLER DIAGNOSIS OF HEMODYNAMICALLY COMPROMISING AIR-EMBOLISM DURING CESAREAN-SECTION
    FONG, J
    GADALLA, F
    GIMBEL, AA
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1990, 37 (02): : 262 - 264
  • [8] PRECORDIAL DOPPLER DIAGNOSIS OF HEMODYNAMICALLY COMPROMISING AIR-EMBOLISM DURING CESAREAN-SECTION
    LANG, S
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1991, 38 (02): : 255 - 256
  • [9] Automatic detection system of venous air embolism employing signal processing methods
    Schlag, R
    Korell, U
    Siegmund, B
    Pfeiffer, M
    Pandit, M
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-6, 1998, : 1925 - 1928
  • [10] Fast detection of venous air embolism in Doppler heart sound using the wavelet transform
    Chan, BCB
    Chan, FHY
    Lam, FK
    Lui, PW
    Poon, PWF
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (04) : 237 - 246