Reliability and validity of a new accelerometer (Wimu®) system for measuring velocity during resistance exercises

被引:17
|
作者
Muyor, Jose M. [1 ]
Granero-Gil, Paulino [2 ]
Pino-Ortega, Jose [3 ]
机构
[1] Univ Almeria, Fac Educ Sci, Res Cent Serv, Lab Kinesiol Biomech & Ergon KIBIOMER Lab, Edificio Humanidades A,Ctra Sacramento S-N, La Canada De San Urbano 04120, Almeria, Spain
[2] Russia Football Federat, Profess Football Team CSKA Moscow, Moscow, Russia
[3] Univ Murcia, Fac Sports Sci, Murcia, Spain
关键词
Linear encoder; T-Force; Smith machine; squat; Wimu system; velocity; LINEAR POSITION TRANSDUCER; BENCH-PRESS; MOVEMENT VELOCITY; SPORTS-MEDICINE; STRENGTH; FORCE; SQUAT; POWER; LOAD; COMPARABILITY;
D O I
10.1177/1754337117731700
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This study had two main goals. The first was to determine the reliability of the Wimu((R)) system (accelerometer) for mean velocity measurements during resistance exercises at 40% and 80% 1 repetition maximum (1RM). The second was to compare the results for the Wimu system to a linear encoder (gold standard) for mean velocity measurements when clipped to the bar during back squat exercises using the Smith machine. In all, 23 trained men (aged 22.3 +/- 3.2 years) participated in this study. At maximum velocity in the concentric phase, they performed 10 repetitions with 40% 1RM and eight repetitions with 80% 1RM while using the Wimu system and T-Force linear encoder simultaneously to record data. Reliability was analysed using intraclass correlation, standard error of measurement and coefficient of variation. The validity was assessed using R-2, intraclass correlation and Bland-Altman plots. The differences in test-retest reliability of both systems and systematic biases were non-significant (p = 0.08-0.85) and very close to 0. The random errors averaged +/- 0.010 m/s. All the calculated coefficient of variations were less than 5% and all measurements had high intraclass correlations (mean: 0.936). Least-square linear regression and intraclass correlations for validity were very close to 1. Significant systematic biases were observed between the linear encoder and the Wimu system (p < 0.001), although the effect sizes were small (0.21-0.44) and standard error of the estimate in concentric and eccentric phases at both intensities was less than 0.030. In conclusion, the findings of this study suggest that the Wimu system is a reliable and valid tool for the assessment of mean velocity during the back squat exercise using the Smith machine. These findings could help coaches and sport researchers evaluate athletes performing resistance exercises similar to squats with a reliable, valid and portable tool.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 50 条
  • [1] Validity and Reliability of a Smartphone Accelerometer for Measuring Lift Velocity in Bench-Press Exercises
    Pelaez Barrajon, Javier
    San Juan, Alejandro F.
    [J]. SUSTAINABILITY, 2020, 12 (06)
  • [2] Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility
    Muyor, Jose M.
    [J]. INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2017, 38 (09) : 691 - 695
  • [3] Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
    Garcia-Pinillos, Felipe
    Latorre-Roman, Pedro A.
    Valdivieso-Ruano, Fernando
    Balsalobre-Fernandez, Carlos
    Parraga-Montilla, Juan A.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART P-JOURNAL OF SPORTS ENGINEERING AND TECHNOLOGY, 2019, 233 (03) : 408 - 415
  • [4] The Criterion Validity and Between-Day Reliability of the Perch for Measuring Barbell Velocity During Commonly Used Resistance Training Exercises
    Weakley, Jonathon
    Munteanu, Gabriella
    Cowley, Nicholas
    Johnston, Rich
    Morrison, Matthew
    Gardiner, Carissa
    Perez-Castilla, Alejandro
    Garcia-Ramos, Amador
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (04) : 787 - 792
  • [5] Validity of an inertial system for measuring velocity, force, and power during hamstring exercises performed on a flywheel resistance training device
    Martin-San Agustin, Rodrigo
    Sanchez-Barbadora, Mariana
    Garcia-Vidal, Jose A.
    [J]. PEERJ, 2020, 8
  • [6] Criterion Validity, and Interunit and Between-Day Reliability of the FLEX for Measuring Barbell Velocity During Commonly Used Resistance Training Exercises
    Weakley, Jonathon
    Chalkley, Daniel
    Johnston, Rich
    Garcia-Ramos, Amador
    Townshend, Andrew
    Dorrell, Harry
    Pearson, Madison
    Morrison, Matthew
    Cole, Michael
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2020, 34 (06) : 1519 - 1524
  • [7] Concurrent validity and reliability of an accelerometer to assess punching velocity in boxers
    Lopez-Laval, Isaac
    Cirer-Sastre, Rafel
    Los Arcos-Lopez De Pariza, Javier
    Corbi, Francisco
    Calleja-Gonzalez, Julio
    Sitko, Sebastian
    [J]. GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE, 2022, 181 (03) : 139 - 145
  • [8] Reliability and validity of a low-cost, wireless sensor and smartphone app for measuring force during isometric and dynamic resistance exercises
    Illera-Dominguez, Victor
    Albesa-Albiol, Lluis
    Castizo-Olier, Jorge
    Garcia-Fresneda, Adrian
    Busca, Bernat
    Ramirez-Lopez, Carlos
    Fernandez-Valdes, Bruno
    [J]. PLOS ONE, 2024, 19 (03):
  • [9] Evaluation of a smartphone accelerometer system for measuring nonlinear dynamics during treadmill walking: Concurrent validity and test-retest reliability
    Di Bacco, Vincenzo E.
    Gage, William H.
    [J]. JOURNAL OF BIOMECHANICS, 2023, 151
  • [10] Validity and reliability of a 3-axis accelerometer for measuring weightlifting movements
    Flores, Francisco J.
    Sedano, Silvia
    de Benito, Ana M.
    Redondo, Juan C.
    [J]. INTERNATIONAL JOURNAL OF SPORTS SCIENCE & COACHING, 2016, 11 (06) : 872 - 879