Validation of a Monte Carlo algorithm for simulation of dispersion due to scattering of a monoenergetic proton beam

被引:0
|
作者
Goulart, D [1 ]
Avery, S [1 ]
Maughan, R [1 ]
McDonough, J [1 ]
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
关键词
D O I
10.1118/1.1998028
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A multi‐leaf collimator is being designed as part of a collaborative effort to build a regional protontherapy facility. The Monte Carlo framework GEANT4 has been chosen to assist in this design by simulating the effects of changing the width of the leaves as well as the distance to the patient. The present work focuses on the validation of the current algorithm by comparing the range of the proton beam and lateral penumbra it produces with published data. Method and Materials: Several experimental setups have been simulated according to the data currently available for comparison. All configurations include a monoenergetic beam and a right‐angled water parallelepiped where the deposited energy is sampled. We report here the specific results obtained from a variety of independent setups including a pencil beam and a 5 cm by 5 cm square beam. The proton ranges obtained for different energies are compared to tabulated ICRU values. Parameters associated with the multiple scattering dispersion of the beam are compared to published experimental data. In addition to that we compare lateral penumbra results obtained in a more realistic beam line configuration to experimental data published by the Orsay Center for Protontherapy. Results: The proton ranges produced agree with the ICRU values for all simulated energies. The level of reproducibility of multiple scattering effects for all the different beam profiles is adequate when compared to reference values published by Szymaowski et al. The lateral penumbra produced by our beam line simulation satisfactorily corresponds to the behavior described by Oozeer et al. Conclusion: GEANT4 is a promising tool for assisting in the design of the MLC. Our implementations reproduce to the extent presently needed, not only proton ranges but also multiple scattering and lateral penumbra effects. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2019 / 2019
页数:1
相关论文
共 50 条
  • [1] A pencil beam algorithm for intensity modulated proton therapy and its validation with Monte Carlo
    Soukup, M
    Fippel, M
    Alber, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S65 - S65
  • [2] Monte Carlo simulation of a therapeutical proton beam line
    Russo, S
    Bucciolini, M
    Compagnucci, A
    Mazal, A
    Nauraye, C
    Rosenwald, JC
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 1998, 14 (02): : 63 - 71
  • [3] Validation of Compton Scattering Monte Carlo Simulation Models
    Weidenspointner, Georg
    Batic, Matej
    Hauf, Steffen
    Hoff, Gabriela
    Kuster, Markus
    Pia, Maria Grazia
    Aracco, Paolo S.
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [4] A generic algorithm for Monte Carlo simulation of proton transport
    Salvat, Francesc
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 316 : 144 - 159
  • [5] Validation and Implementation of Proton Pencil Beam Scanning Nozzle Using TOPAS Monte Carlo Simulation
    Lin, C.
    Feng, Y.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E875 - E875
  • [6] Study of proton beam spreading for a solid beam stopper double scattering method using Monte Carlo simulation
    Ju Zhi-Ping
    Cao Wu-Fei
    Liu Xiao-Wei
    [J]. ACTA PHYSICA SINICA, 2010, 59 (01) : 199 - 202
  • [7] Monte Carlo Simulation of Laser Beam Scattering by Water Droplets
    Wang Biao
    Tong Guang-de
    Lin Jia-xuan
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: LASER SENSING AND IMAGING AND APPLICATIONS, 2013, 8905
  • [8] Development and validation of the Dynamic Collimation Monte Carlo simulation package for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Rana, Suresh
    Gutierrez, Alonso N.
    Hill, Patrick M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06) : 3172 - 3185
  • [9] Experimental depth dose curves of a 67.5 MeV proton beam for benchmarking and validation of Monte Carlo simulation
    Faddegon, Bruce A.
    Shin, Jungwook
    Castenada, Carlos M.
    Ramos-Mendez, Jose
    Daftari, Inder K.
    [J]. MEDICAL PHYSICS, 2015, 42 (07) : 4199 - 4210
  • [10] Technical Note: An approach to building a Monte Carlo simulation model for a double scattering proton beam system
    Yuan, Jiankui
    Ellis, Rodney
    Machtay, Mitchell
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : 2660 - 2666