Depth of interaction for PET using segmented crystals

被引:0
|
作者
MacDonald, LR [1 ]
Dahlbom, M [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Div Nucl Med, Dept Mol & Med Pharmacol, Los Angeles, CA 90095 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We investigate the use of segmented scintillation crystals to obtain depth of interaction (DOI) information in positron emission tomography (PET) detectors. Coupling segmented crystals to a photodetector at one end yields distinct pulse heights from the different segments and the depth of interaction is determined to within the segment length. The method is simple to implement because no additional instrumentation is required. Since the technique uses light attenuation, a scintillator with sufficient light yield is required. We found that 4x4x10 mm(3) segments of lutetium oxyorthosilicate (LSO) provide enough light for this application. The energy spectra of segmented crystals show clearly distinct photopeaks for each segment and the photopeak separation can be adjusted by altering the the optical couple between segments. An ambiguity exists between photopeak events from an attenuated crystal and scattered events from the crystal without attenuation. This leads to the same error as a system with no depth information. Using 10mm segments we find that the fraction of the events in the lower energy window due to scatter contamination in 2-segment (3-segment) crystals increases from 8% (13%) to 32% (60%) for a source in air vs. behind 16 cm of water. In imaging situations with minimal scatter medium (e.g. rodents) DOI is accurately provided by the segmented crystals, while in the presence of scatter (e,g, WE, cardiac) the method is only partially effective, and potential improvements in scanner cost, sensitivity and/or image quality must be carefully evaluated.
引用
收藏
页码:1293 / 1297
页数:5
相关论文
共 50 条
  • [1] Depth of interaction for PET using segmented crystals
    MacDonald, Lawrence R.
    Dahlbom, Magnus
    IEEE Transactions on Nuclear Science, 1998, 45 (4 pt 2): : 2144 - 2148
  • [2] Depth of interaction for PET using segmented crystals
    MacDonald, LR
    Dahlbom, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) : 2144 - 2148
  • [3] Segmented LSO crystals for depth-of-interaction encoding in PET
    Moisan, C
    Andreaco, MS
    Rogers, JG
    Paquet, S
    Vozza, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3030 - 3035
  • [4] Segmented LSO crystals for depth-of-interaction encoding in PET
    TRIUMF, Vancouver, BC, Canada
    IEEE Trans Nucl Sci, 6 pt 2 (3030-3035):
  • [5] Segmented LSO crystals for depth-of-interaction encoding in PET
    Moisan, C
    Andreaco, MS
    Rogers, JG
    Paquet, S
    Vozza, D
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1112 - 1116
  • [6] Parallax correction in PET using depth of interaction information
    MacDonald, LR
    Dahlbom, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) : 2232 - 2237
  • [7] Parallax correction in PET using depth of interaction information
    MacDonald, Lawrence R.
    Dahlbom, Magnus
    IEEE Transactions on Nuclear Science, 1998, 45 (4 pt 2): : 2232 - 2237
  • [8] Parallax correction in PET using depth of interaction information
    MacDonald, LR
    Dahlbom, M
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1605 - 1609
  • [9] MONTE-CARLO OPTIMIZATION OF DEPTH-OF-INTERACTION RESOLUTION IN PET CRYSTALS
    DEVOL, TA
    MOSES, WW
    DERENZO, SE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (02) : 170 - 174
  • [10] A depth of interaction detector for PET with GSO crystals doped with different amount of Ce
    Inadama, N
    Murayama, H
    Omura, T
    Yamashita, T
    Yamamoto, S
    Ishibashi, H
    Kawai, H
    Omi, K
    Umehara, T
    Kasahara, T
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1099 - 1103