Comparison of 2-D and 3-D coupled electromagnetic and structure-dynamic simulation of electrical machines

被引:20
|
作者
van der Giet, Michael [1 ]
Schlensok, Christoph [1 ]
Schmuelling, Benedikt [1 ]
Hameyer, Kay [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Elect Machines, D-52062 Aachen, Germany
关键词
finite element (FE); finite-element method (FEM); noise and vibration of electrical machines; switched reluctance machine (SRM); 2-D; 3-D;
D O I
10.1109/TMAG.2007.916121
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For the coupled electromagnetic and structure-dynamic simulation of electrical machines, various 2-D and 3-D techniques are available. This paper reviews and compares them. The strength as well as the weaknesses of these methods are pointed out. Numerical results for the analysis of a switched reluctance machine (SRM) as an example evaluate accuracy and computational effort. It shows that the 2-D simulation gives quite accurate results, as long as the axial effects and 3-D mode shapes are not relevant.