Performance analysis of a low-power tangential flow turbine with rotary channel

被引:5
|
作者
Barbarelli, S [1 ]
Florio, G [1 ]
Scornaienchi, NM [1 ]
机构
[1] Univ Calabria, Dept Mech, I-87036 Cosenza, Italy
关键词
D O I
10.1115/1.1944008
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A tangential flow prototype turbine with a rotating channel containing five optimized deflectors is presented. This atypical turbine configuration may be useful for application in the low n(s) high d(s) region of the Balje chart, where conventional turbines offer very poor performances. A 70 kW maximum broke power, pressured-air test rig has been used for the analysis of operating characteristics, such as pressure, temperature, flow rate, and broke power. An electronic data acquisition system for automated measurement management was employed. An experimental campaign was carried out to identify the distribution of the pressure in the rotary ducts of the turbine. The results indicate the presence of a pressure gradient in the immediate vicinity of the inlet jet that is strongly attenuated when the ducts are not directly in contact with the jet.
引用
收藏
页码:272 / 279
页数:8
相关论文
共 50 条
  • [1] Low-power start to tidal turbine
    不详
    PROFESSIONAL ENGINEERING, 2008, 21 (13) : 10 - 10
  • [2] Low-power rotary clock array design
    Yu, Zhengtao
    Liu, Xun
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2007, 15 (01) : 5 - 12
  • [3] Performance Improvement of a Low-Power Wind Turbine Using Conical Sections
    Mohanan, Janesh N.
    Sundaramoorthy, Kumaravel
    Sankaran, Ashok
    ENERGIES, 2021, 14 (17)
  • [4] A HIGH-PERFORMANCE LOW-POWER CMOS CHANNEL FILTER
    BLACK, WC
    ALLSTOT, DJ
    REED, RA
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1980, 15 (06) : 929 - 938
  • [5] RBMK CHANNEL BOILING DURING LOSS OF COOLANT FLOW AT LOW-POWER
    KOBZAR, LL
    MIRONOV, YV
    FOMICHEVA, TI
    KHUDYKIN, AM
    SOVIET ATOMIC ENERGY, 1989, 67 (06): : 864 - 867
  • [6] Analysis of Low-Power Steam Turbine With One Extraction for Marine Applications
    Medica-Viola, Vedran
    Mrzljak, Vedran
    Andelic, Nikola
    Jelic, Maro
    NASE MORE, 2020, 67 (02): : 87 - 95
  • [7] Low-Power Vertical Water Turbine.
    Kuczewski, Stanislaw
    Prywer, Jerzy
    Przeglad Mechaniczny, 1987, 46 (12): : 15 - 16
  • [8] Coverage Performance Analysis of FeICIC Low-Power Subframes
    Hu, Haonan
    Weng, Jialai
    Zhang, Jie
    IEEE TRANSACTIONS ON WIRELESS COMMUNICATIONS, 2016, 15 (08) : 5603 - 5614
  • [9] Physics performance analysis of low-power tokamak reactors
    Ludwig, G. O.
    Andrade, M. C. R.
    Gryaznevich, M.
    Todd, T. N.
    NUCLEAR FUSION, 2009, 49 (08)