Fixation of tendon grafts for collateral ligament reconstructions: A cadaveric biomechanical study

被引:11
|
作者
Lee, SK [1 ]
Kubiak, EN [1 ]
Liporace, FA [1 ]
Parisi, DM [1 ]
Iesaka, K [1 ]
Posner, MA [1 ]
机构
[1] NYU, Sch Med, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY USA
来源
关键词
hand; interference screw; ligament reconstruction; tendon graft;
D O I
10.1016/j.jhsa.2004.12.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the biomechanical properties of 4 methods of fixation of tendon grafts to bone as used for ligament reconstructions. Methods: Thirty-two metacarpals were harvested from fresh-frozen cadavers and stripped of soft tissue. Flexor tendons were harvested from the same cadavers and cut into 2-mm-wide strips. Each tendon was fixed to a metacarpal head at the site of origin of a collateral ligament. Four different methods of fixation were tested. In group 1 the tendon was fixed to the bone with a 4.0-mm Arthrex bio-tenodesis interference screw (Arthrex, Inc., Naples, FL). In group 2 the tendon was passed through a bone tunnel and fixed with a 3.2-mm mini-Acutrak screw (Acumed, LLC, Hillsboro, OR) that was inserted in interference mode. In group 3 the tendon was passed through a bone tunnel and fixed with sutures tied over a polyethylene button. In group 4 the tendon was fixed with a mini-Mitek bone suture anchor (Mitek Worldwide, Norwood, MA). All specimens were clamped into a linear loading machine and loaded until failure. Statistical analysis was performed by 1-way analysis of variance testing. Results: The differences in maximal tensile strength and stiffness were statistically significant when comparing any 2 groups. The Arthrex biotenodesis interference screw was the strongest and stiffest fixation method, followed by the Acutrak screw inserted in interference mode. Next was the suture tied over a button method. The mini-Mitek bone suture anchor was the weakest. Conclusions: Interference screw fixation of tendons to bone has statistically significant higher pullout strength and stiffness than 2 other commonly used fixation methods. The use of interference screws for fixation of tendon grafts to bone for hand ligament reconstructions is a promising new surgical technique.
引用
收藏
页码:1051 / 1055
页数:5
相关论文
共 50 条
  • [1] Cadaveric Biomechanical Analysis of 3 Lateral Ulnar Collateral Ligament Reconstructions
    Chauhan, Aakash
    Baratz, Mark E.
    Schimoler, Patrick
    Ruch, David
    Miller, Mark C.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2018, 32 (03) : e86 - e91
  • [2] Bone Staples Provide Favorable Primary Stability in Cortical Fixation of Tendon Grafts for Medial Collateral Ligament Reconstruction: A Biomechanical Study
    Glasbrenner, Johannes
    Deichsel, Adrian
    Raschke, Michael J.
    Briese, Thorben
    Frank, Andre
    Herbort, Mirco
    Herbst, Elmar
    Kittl, Christoph
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (07)
  • [3] The Biomechanical Stability of Bone Staples in Cortical Fixation of Tendon Grafts for Medial Collateral Ligament Reconstruction Depends on the Implant Design
    Deichsel, Adrian
    Raschke, Michael J.
    Herbst, Elmar
    Peez, Christian
    Oeckenpoehler, Simon
    Briese, Thorben
    Wermers, Jens
    Kittl, Christoph
    Glasbrenner, Johannes
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (14): : 3827 - 3831
  • [4] Acromioclavicular reconstructions with hamstring tendon grafts: A comparative biomechanical study
    Erak, Sani
    Pelletier, Matthew H.
    Woods, Kevin R.
    Smith, Paul N.
    Walsh, William R.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (05) : 772 - 778
  • [5] Isometric Placement of Lateral Ulnar Collateral Ligament Reconstructions A Biomechanical Study
    Goren, David
    Budoff, Jeffrey E.
    Hipp, John A.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2010, 38 (01): : 153 - 159
  • [6] Biomechanical evaluation of graft fixation techniques for acromioclavicular joint reconstructions using coracoclavicular tendon grafts
    Tashjian, Robert Z.
    Southam, Jodi D.
    Clevenger, Todd
    Bachus, Kent N.
    [J]. JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (11) : 1573 - 1579
  • [7] Biomechanical Comparison of Acromioclavicular Joint Reconstructions Using Coracoclavicular Tendon Grafts With and Without Coracoacromial Ligament Transfer
    Clevenger, Todd
    Vance, Richard E.
    Bachus, Kent N.
    Burks, Robert T.
    Tashjian, Robert Z.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (01): : 24 - 30
  • [8] Adjustable Cortical Fixation Device for Quadriceps Tendon Repair: A Cadaveric Biomechanical Study
    Gould, Heath P.
    Rate, William R.
    Abbasi, Pooyan
    Mistretta, Katherine L.
    Hammond, Jason W.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (01)
  • [9] MR FOR ASSESSING ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTIONS BY TENDON GRAFTS
    ALLGAYER, B
    GRADINGER, R
    LEHNER, K
    FLOCK, K
    GEWALT, Y
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (04): : 294 - 298
  • [10] Complications in anterior cruciate ligament reconstructions with patellar tendon grafts
    Stapleton, TR
    [J]. SPORTS MEDICINE AND ARTHROSCOPY REVIEW, 1997, 5 (02): : 156 - 162