Impact of Wind Speed on Response of Diffusion-Type Radon-Thoron Detectors to Thoron

被引:8
|
作者
Omori, Yasutaka [1 ]
Tamakuma, Yuki [2 ]
Nugraha, Eka Djatnika [3 ]
Suzuki, Takahito [4 ]
Saputra, Miki Arian [3 ]
Hosoda, Masahiro [2 ,3 ]
Tokonami, Shinji [2 ]
机构
[1] Fukushima Med Univ, Dept Radiat Phys & Chem, 1 Hikarigaoka, Fukushima 9601295, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
[3] Hirosaki Univ, Grad Sch Hlth Sci, 66-1 Hon Cho, Hirosaki, Aomori 0368564, Japan
[4] Fuji Elect Co Ltd, 1 Fujimachi, Hino, Tokyo 1918502, Japan
关键词
advection; air exchange; Darcy flow; diffusion-type detector; laminar flow; non-Darcy flow; porous medium; radon; thoron; turbulent flow; NON-DARCY FLOW; INDOOR; INTERFERENCE; COEFFICIENTS; PERFORMANCE; INHALATION; ALPHAGUARD; PRODUCTS; MONITOR;
D O I
10.3390/ijerph17093178
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air exchange through a porous medium depends partly on a pressure gradient induced in it, i.e., air-flow conditions of the outer air. Consequently, response of diffusion-type detectors to radon and thoron may vary with air-flow conditions surrounding the detectors. This effect may be significant for thoron measurement because thoron has a shorter half-life than radon. The present study examined response of diffusion-type detectors (RADUETs and one AlphaGUARD) to thoron with respect to wind speed using a thoron calibration chamber. Response of RADUETs to thoron increased with wind speed. Response of the AlphaGUARD increased with wind speed, but it became constant at a high wind speed. Different response trends to thoron between the RADUETs and the AlphaGUARD could be qualitatively explained by flow states induced by the pressure gradient in the filter or the sponge of these detectors. For RADUETs, laminar (Darcy) flow was induced in the sponge in the examined wind speed range, which meant that thoron entry into the detector increased with wind speed. For the AlphaGUARD, laminar flow was induced in the filter in the low wind speed range, whereas flow was changed to turbulent (non-Darcy) flow at a high wind speed for which thoron entry into the detector did not depend on wind speed.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] EFFECTS OF AIR EXCHANGE PROPERTY OF PASSIVE-TYPE RADON-THORON DISCRIMINATIVE DETECTORS ON PERFORMANCE OF RADON AND THORON MEASUREMENTS
    Omori, Y.
    Janik, M.
    Sorimachi, A.
    Ishikawa, T.
    Tokonami, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) : 140 - 145
  • [2] Thoron exposure in the radon-thoron prone area of the Adamawa Region, Cameroon
    Bachirou, Soumayah
    Saidou
    Mishra, Rosaline
    Kranrod, Chutima
    Hosoda, Masahiro
    Jalaluddin, Sabahet
    Sapra, Balvinder K.
    Njock, Moise Godfroy Kwato
    Tokonami, Shinji
    [J]. APPLIED RADIATION AND ISOTOPES, 2024, 213
  • [3] Preface: Radon-thoron instrumentation and measurement
    Janik, Miroslaw
    Kavasi, Norbert
    Matey, James R.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [4] Performance test of passive radon-thoron discriminative detectors on environmental parameters
    Sorimachi, Atsuyuki
    Tokonami, Shinji
    Omori, Yasutaka
    Ishikawa, Tetsuo
    [J]. RADIATION MEASUREMENTS, 2012, 47 (06) : 438 - 442
  • [5] International intercomparisons of integrating radon/thoron detectors with the NIRS radon/thoron chambers
    Janik, M.
    Tokonami, S.
    Kranrod, C.
    Sorimachi, A.
    Ishikawa, T.
    Hassan, N. M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 436 - 439
  • [6] AUTOMATED RADON-THORON MONITOR FOR EARTHQUAKE PREDICTION RESEARCH
    SHAPIRO, MH
    MELVIN, J
    TOMBRELLO, TA
    WHITCOMB, JH
    [J]. BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (11): : 1313 - 1313
  • [7] A new passive radon-thoron discriminative measurement system
    Sciocchetti, G.
    Sciocchetti, A.
    Giovannoli, P.
    DeFelice, P.
    Cardellini, F.
    Cotellessa, G.
    Pagliari, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) : 462 - 467
  • [8] Contribution from thoron on the response of passive radon detectors
    Tokonami, S
    Yang, ML
    Sanada, T
    [J]. HEALTH PHYSICS, 2001, 80 (06): : 612 - 615
  • [9] AUTOMATED RADON-THORON MONITOR FOR EARTHQUAKE PREDICTION RESEARCH
    MELVIN, JD
    SHAPIRO, MH
    COPPING, NA
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1978, 153 (01): : 239 - 251
  • [10] Variable Strength in Thoron Interference for a Diffusion-Type Radon Monitor Depending on Ventilation of the Outer Air
    Omori, Yasutaka
    Shimo, Michikuni
    Janik, Miroslaw
    Ishikawa, Tetsuo
    Yonehara, Hidenori
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (03)