Small spot size versus large spot size: Effect on plan quality for lung cancer in pencil beam scanning proton therapy

被引:4
|
作者
Rana, Suresh [1 ,2 ,3 ,4 ]
Rosenfeld, Anatoly B. [4 ]
机构
[1] Oklahoma Proton Ctr, Dept Med Phys, Oklahoma City, OK USA
[2] Baptist Hlth South Florida, Boca Raton Reg Hosp, Lynn Canc Inst, Dept Radiat Oncol, 701 NW 13 St, Boca Raton, FL 33486 USA
[3] Florida Int Univ, Dept Radiat Oncol, Herbert Wertheim Coll Med, Miami, FL 33199 USA
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
来源
关键词
interplay; lung cancer; NTCP; pencil beam scanning; plan robustness; proton therapy; COMPLICATION PROBABILITY; RADIATION-THERAPY; OPTIMIZATION; MOTION; IMPACT; UNCERTAINTIES; ROBUSTNESS;
D O I
10.1002/acm2.13512
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of the current study was to evaluate the impact of spot size on the interplay effect, plan robustness, and dose to the organs at risk for lung cancer plans in pencil beam scanning (PBS) proton therapy Methods The current retrospective study included 13 lung cancer patients. For each patient, small spot (similar to 3 mm) plans and large spot (similar to 8 mm) plans were generated. The Monte Carlo algorithm was used for both robust plan optimization and final dose calculations. Each plan was normalized, such that 99% of the clinical target volume (CTV) received 99% of the prescription dose. Interplay effect was evaluated for treatment delivery starting in two different breathing phases (T0 and T50). Plan robustness was investigated for 12 perturbed scenarios, which combined the isocenter shift and range uncertainty. The nominal and worst-case scenario (WCS) results were recorded for each treatment plan. Equivalent uniform dose (EUD) and normal tissue complication probability (NTCP) were evaluated for the total lung, heart, and esophagus. Results In comparison to large spot plans, the WCS values of small spot plans at CTV D-95%, D-96%, D-97%, D-98%, and D-99% were higher with the average differences of 2.2% (range, 0.3%-3.7%), 2.3% (range, 0.5%-4.0%), 2.6% (range, 0.6%-4.4%), 2.7% (range, 0.9%-5.2%), and 2.7% (range, 0.3%-6.0%), respectively. The nominal and WCS mean dose and EUD for the esophagus, heart, and total lung were higher in large spot plans. The difference in NTCP between large spot and small spot plans was up to 1.9% for the total lung, up to 0.3% for the heart, and up to 32.8% for the esophagus. For robustness acceptance criteria of CTV D-95% >= 98% of the prescription dose, seven small spot plans had all 12 perturbed scenarios meeting the criteria, whereas, for 13 large spot plans, there were >= 2 scenarios failing to meet the criteria. Interplay results showed that, on average, the target coverage in large spot plans was higher by 1.5% and 0.4% in non-volumetric and volumetric repainting plans, respectively. Conclusion For robustly optimized PBS lung cancer plans in our study, a small spot machine resulted in a more robust CTV against the setup and range errors when compared to a large spot machine. In the absence of volumetric repainting, large spot PBS lung plans were more robust against the interplay effect. The use of a volumetric repainting technique in both small and large spot PBS lung plans led to comparable interplay target coverage.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Impact of Proton Pencil Beam Spot Size On Breast Plan Quality
    Liang, X.
    Bradley, J.
    Zheng, D.
    Flampouri, S.
    Ho, M.
    Li, Z.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2870 - 2871
  • [2] Impact of Spot Size and Beam-Shaping Devices on the Treatment Plan Quality for Pencil Beam Scanning Proton Therapy
    Moteabbed, Maryam
    Yock, Torunn I.
    Depauw, Nicolas
    Madden, Thomas M.
    Kooy, Hanne M.
    Paganetti, Harald
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (01): : 190 - 198
  • [3] Effects of Proton Pencil Beam Scanning Spot Size on Head and Neck Treatment Plan Quality
    Mundy, D.
    Foote, R. L.
    Beltran, C.
    Herman, M. G.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E603 - E603
  • [4] The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality
    Langner, U.
    Langen, K.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3499 - 3499
  • [5] Motion Interplay as a Function of Patient Parameters and Spot Size in Spot Scanning Proton Therapy for Lung Cancer
    Grassberger, Clemens
    Dowdell, Stephen
    Lomax, Antony
    Sharp, Greg
    Shackleford, James
    Choi, Noah
    Willers, Henning
    Paganetti, Harald
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 86 (02): : 380 - 386
  • [6] Impact of spot size on plan quality of spot scanning proton radiosurgery for peripheral brain lesions
    Wang, Dongxu
    Dirksen, Blake
    Hyer, Daniel E.
    Buatti, John M.
    Sheybani, Arshin
    Dinges, Eric
    Felderman, Nicole
    TenNapel, Mindi
    Bayouth, John E.
    Flynn, Ryan T.
    [J]. MEDICAL PHYSICS, 2014, 41 (12)
  • [7] Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy
    Yu, Juan
    Beltran, Chris J.
    Herman, Michael G.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 96 - 103
  • [8] Spot Size and Position Analysis of a Pencil Beam Scanning System
    Perles, L.
    Coutinho, L.
    Rana, S.
    Gutierrez, A.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E426 - E426
  • [9] Implication of Spot Position Error On Plan Quality in Pencil-Beam Proton Therapy
    Yu, J.
    Beltran, C.
    Herman, M.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [10] Impact of errors in spot size and spot position in robustly optimized pencil beam scanning proton-based stereotactic body radiation therapy (SBRT) lung plans
    Rana, Suresh
    Rosenfeld, Anatoly B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 147 - 154