Determination of deferasirox in human plasma by short-end injection and sweeping with a field-amplified sample stacking and micellar electrokinetic chromatography

被引:16
|
作者
Lin, Hung-Ju [1 ]
Hsieh, Kun-Pin [1 ]
Chiou, Shyh-Shin [2 ,3 ]
Kou, Hwang-Shang [1 ]
Wu, Shou-Mei [1 ,4 ]
机构
[1] Kaohsiung Med Univ, Coll Pharm, Sch Pharm, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ Hosp, Dept Pediat, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Coll Med, Sch Med, Kaohsiung 807, Taiwan
[4] Natl Sun Yat Sen Univ, Coll Sci, Dept Chem, Kaohsiung 804, Taiwan
关键词
Deferasirox; beta-Thalassemia; Short-end injection; Field-amplified sample stacking; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; BETA-THALASSEMIA MAJOR; ORAL IRON CHELATOR; RENAL DYSFUNCTION; COMPLEX; PHARMACOKINETICS; COMPLICATIONS; TRANSFUSION; METABOLITES;
D O I
10.1016/j.jpba.2016.06.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A field-amplified sample stacking-sweeping micellar electrokinetic chromatography with short-end injection was established for determination of deferasirox (DFX) in plasma. DFX was extracted from plasma and reconstituted with deionized water (lower conductivity solution). Capillary (effective length, 10 cm) was filled with background electrolyte (40 mM phosphate buffer, pH 4.5, containing 20% methanol). After sample loading from outlet end at 5 psi for 15 s, separation was carried out by applying high voltage at 15 kV for 10 min. Sodium dodecyl sulfate (SDS) was used to sweep DFX for enhancing sensitivity. The optimal CE separation conditions were 40 mM phosphate buffer at pH 4.5 containing 100 mM SDS and 20% methanol. The analysis time was about 3.5 min for DFX. The calibration curve of DFX was ranged from 1 to 20 mu g/ml. The linearity (r) was more than 0.998. RSD and RE in intra- and inter-day assays were all below 12.14%. The limit of detection (LOD, S/N = 3) for DFX was 0.31 mu g/ml. The sensitivity enhancement factor between sweeping-FASS MEKC and capillary zone electrophoresis is 3.3. Finally, the method was applied for determination of DFX in beta-thalassemia patients. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:497 / 502
页数:6
相关论文
共 50 条
  • [1] Field-amplified sample injection and sweeping micellar electrokinetic chromatography in analysis of glyphosate and aminomethylphosphonic acid in wheat
    Gotti, Roberto
    Fiori, Jessica
    Bosi, Sara
    Dinelli, Giovanni
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1601 : 357 - 364
  • [2] Sensitive determination of pyrrolizidine alkaloids in Tussilago farfara L. by field-amplified, sample-stacking, sweeping micellar electrokinetic chromatography
    Cao, Kun
    Xu, Yi
    Mu, Xiuni
    Zhang, Qing
    Wang, Renjie
    Lv, Junjiang
    [J]. JOURNAL OF SEPARATION SCIENCE, 2016, 39 (21) : 4243 - 4250
  • [3] Using micellar electrokinetic chromatography with short-end injection
    Anastos, N
    Lewis, SW
    Barnett, NW
    Pearson, JR
    Kirkbride, KP
    [J]. JOURNAL OF FORENSIC SCIENCES, 2005, 50 (01) : 37 - 42
  • [4] FIELD-AMPLIFIED SAMPLE STACKING IN MICELLAR ELECTROKINETIC CHROMATOGRAPHY FOR ON-COLUMN SAMPLE CONCENTRATION OF NEUTRAL MOLECULES
    LIU, ZY
    SAM, P
    SIRIMANNE, SR
    MCCLURE, PC
    GRAINGER, J
    PATTERSON, DG
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1994, 673 (01) : 125 - 132
  • [5] Simultaneous Separation of Eight Benzodiazepines in Human Urine Using Field-Amplified Sample Stacking Micellar Electrokinetic Chromatography
    Oledzka, Ilona
    Kulinska, Zofia
    Prahl, Adam
    Baczek, Tomasz
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (06) : 436 - 443
  • [6] A three-step stacking capillary electrophoresis of field-amplified sample injection, sweeping, and micellar collapse for determination of dabigatran and its active metabolite in human plasma
    Cheng, Cheng-Wei
    Feng, Wen-Han
    Tang, Wei-Hua
    Kou, Hwang-Shang
    Wang, Chun-Chi
    Wu, Shou-Mei
    [J]. JOURNAL OF FOOD AND DRUG ANALYSIS, 2022, 30 (01) : 88 - 103
  • [7] Vortex-assisted liquid-liquid extraction combined with field-amplified sample injection and sweeping micellar electrokinetic chromatography for improved determination of β-blockers in human urine
    Jouyban, Abolghasem
    Sorouraddin, Mohammad Hossein
    Farajzadeh, Mir Ali
    Somi, Mohammad Hossein
    Fazeli-Bakhtiyari, Rana
    [J]. TALANTA, 2016, 149 : 298 - 309
  • [8] Effect of a Low-conductivity Zone on Field-amplified Sample Stacking in Microchip Micellar Electrokinetic Chromatography
    Kenji Sueyoshi
    Fumihiko Kitagawa
    Koji Otsuka
    [J]. Analytical Sciences, 2013, 29 : 133 - 138
  • [9] Effect of a Low-conductivity Zone on Field-amplified Sample Stacking in Microchip Micellar Electrokinetic Chromatography
    Sueyoshi, Kenji
    Kitagawa, Fumihiko
    Otsuka, Koji
    [J]. ANALYTICAL SCIENCES, 2013, 29 (01) : 133 - 138
  • [10] Dialkyl anionic surfactant in field-amplified sample injection and sweeping-micellar electrokinetic chromatography for determination of eight leanness-promoting β-agonists in animal feeds
    Hsieh, Sung-Yu
    Wang, Chun-Chi
    Kou, Hwang-Shang
    Wu, Shou-Mei
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 141 : 222 - 228