共 50 条
Development of the asthma control test: A survey for assessing asthma control
被引:2113
|作者:
Nathan, RA
Sorkness, CA
Kosinski, M
Schatz, M
Li, JT
Marcus, P
Murray, JJ
Pendergraft, TB
机构:
[1] GlaxoSmithKline, Global Hlth Outcomes, Res Triangle Pk, NC 27709 USA
[2] Asthma & Allergy Associates & Res Ctr, Colorado Springs, CO USA
[3] Qual Metr Inc, Lincoln, RI USA
[4] Univ Wisconsin, Sch Pharm, Madison, WI 53706 USA
[5] Kaiser Permanente Med Ctr, Dept Allergy, San Diego, CA USA
[6] Mayo Med Ctr, Rochester, MN USA
[7] Nassau Chest Phys, Great Neck, NY USA
[8] Vanderbilt Univ, Med Ctr, Nashville, TN USA
关键词:
asthma;
questionnaires;
outcomes research;
patient care management;
screening;
D O I:
10.1016/j.jaci.2003.09.008
中图分类号:
R392 [医学免疫学];
学科分类号:
100102 ;
摘要:
Background: Asthma guidelines indicate that the goal of treatment should be optimum asthma control. In a busy clinic practice with limited time and resources, there is need for a simple method for assessing asthma control with or without lung function testing. Objectives: The objective of this article was to describe the development of the Asthma Control Test (ACT), a patient-based tool for identifying patients with poorly controlled asthma. Methods: A 22-item survey was administered to 471 patients with asthma in the offices of asthma specialists. The specialist's rating of asthma control after spirometry was also collected. Stepwise regression methods were used to select a subset of items that showed the greatest discriminant validity in relation to the specialist's rating of asthma control. Internal consistency reliability was computed, and discriminant validity tests were conducted for ACT scale scores. The performance of ACT was investigated by using logistic regression methods and receiver operating characteristic analyses. Results: Five items were selected from regression analyses. The internal consistency reliability of the 5-itern ACT scale was 0.84. ACT scale scores discriminated between groups of patients differing in the specialist's rating of asthma control IF = 34.5, P <.00001), the need for change in patient's therapy (F = 40.3, P <.00001), and percent predicted FEV1 (F = 4.3, P =.0052). As a screening tool, the overall agreement between ACT and the specialist's rating ranged from 71 % to 78 % depending on the cut points used, and the area under the receiver operating characteristic curve was 0.77. Conclusion: Results reinforce the usefulness of a brief, easy to administer, patient-based index of asthma control.
引用
收藏
页码:59 / 65
页数:7
相关论文