Translation and reliability and validity testing of a Japanese version of the Intermittent Self-Catheterization Questionnaire among disposable and reusable catheter users

被引:11
|
作者
Yoshida, Mikako [1 ]
Igawa, Yasuhiko [2 ]
Higashimura, Shiho [1 ]
Suzuki, Motofumi [3 ]
Niimi, Aya [4 ]
Sanada, Hiromi [1 ]
机构
[1] Univ Tokyo, Dept Gerontol Nursing Wound Care Management, Grad Sch Med, Tokyo, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Continence Med, Tokyo, Japan
[3] Tokyo Teishin Hosp, Dept Urol, Tokyo, Japan
[4] Univ Tokyo, Grad Sch Med, Dept Urol, Tokyo, Japan
关键词
intermittent self-catheterization; quality of life; reusable catheter; scale reliability; scale validity; QUALITY-OF-LIFE; PEOPLE; DIFFICULTIES; VALIDATION;
D O I
10.1002/nau.23111
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
AimsQuality of life in the context of intermittent self-catheterization varies depending on the type of catheter used. This study translated into Japanese, evaluated the feasibility, reliability, and validity of the Intermittent Self-Catheterization Questionnaire (ISC-Q) among users of both reusable and disposable catheters, and examined the differences of it between them. MethodsSeventy patients (age meanSD: 62.817.7 years) completed the Japanese version of the ISC-Q (J-ISC-Q) at baseline and 4 weeks later. Spearman's correlation coefficients between the J-ISC-Q, and Qualiveen((R)) and the SF-12 were used for the translated scale's discriminant and convergent validity. Reliability was evaluated by intraclass correlation coefficients (ICC), the Bland-Altman method, and Cronbach's alpha. ResultsParticipants answered all questionnaire items with no difficulties. Scores on the convenience domain were significantly higher among reusable compared to disposable catheter users (P=0.039). The J-ISC-Q had significantly strong correlations with the Qualiveen((R)) total scale (=-0.712 to -0.237), but weak correlations with the SF-12 total scale (=-0.231 to 0.474). Internal consistency was good (Cronbach's alphas>0.706), and test-retest reliability was acceptable (ICC>0.6) for the total scale and the four J-ISC-Q domains. The Bland-Altman analysis showed no systematic error between scores at baseline and 4 weeks later for the total scale and four domains of the J-ISC-Q. ConclusionsThe J-ISC-Q has acceptable reliability and validity for assessing both reusable and disposable catheter users, and can be used to promote tailored individualized interventions based on the impact of catheter use.
引用
收藏
页码:1356 / 1362
页数:7
相关论文
共 44 条
  • [1] REUSABLE CATHETER FOR STERILE INTERMITTENT SELF-CATHETERIZATION
    WU, Y
    BOYINK, MA
    HAMILTON, BB
    NANNINGA, JB
    ROSEN, JS
    BETTS, HB
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1978, 59 (11): : 557 - 557
  • [2] Reliability and validity of the Turkish version of the intermittent self-catheterization questionnaire in patients with spinal cord injury
    Yesil, Hilal
    Akkoc, Yesim
    Yildiz, Necmettin
    Calis, Funda Atamaz
    Inceoglu, Alperen
    Yildiz, Emrullah Fatih
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2020, 52 (08) : 1437 - 1442
  • [3] Reliability and validity of the Turkish version of the intermittent self-catheterization questionnaire in patients with spinal cord injury
    Hilal Yeşil
    Yeşim Akkoc
    Necmettin Yıldız
    Funda Atamaz Calıs
    Alperen İnceoğlu
    Rıdvan Isık
    Emrullah Fatih Yıldız
    International Urology and Nephrology, 2020, 52 : 1437 - 1442
  • [4] Development and validation of the Italian version of the Intermittent Self-Catheterization Questionnaire
    Scivoletto, Iorgio
    Musco, Stefania
    De Nunzio, Cosimo
    Del Popolo, Giulio
    MINERVA UROLOGICA E NEFROLOGICA, 2017, 69 (04) : 384 - +
  • [5] DEVELOPMENT AND VALIDATION OF THE ITALIAN VERSION OF THE INTERMITTENT SELF-CATHETERIZATION QUESTIONNAIRE
    Musco, Stefania
    Scivoletto, Giorgio
    Zampa, Agostino
    Cianfrocca, Mirella
    Felzani, Giorgio
    Marangoni, Anna
    Verderosa, Francesco
    Castiglioni, Mirco
    De Palma, Luisa
    Nardulli, Roberto
    Sacchetti, Rinaldo
    Spandonaro, Cristina
    Pistolesi, Donatella
    Mazzini, Ambra
    Corsini, Carla
    Di Girolamo, Angela
    Del Popolo, Giulio
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S52 - S53
  • [6] DEVELOPMENT AND VALIDATION OF THE ITALIAN VERSION OF THE INTERMITTENT SELF-CATHETERIZATION QUESTIONNAIRE (ISC-Q)
    Del Popolo, G.
    Scivoletto, G.
    Biscotto, S.
    Cazzaniga, M.
    Zanollo, L.
    Campus, G.
    Bonaccorsi, A.
    Bonavita, J.
    Musco, S.
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S253 - S255
  • [7] Assessment of Intermittent Self-Catheterization Procedures in Patients with Neurogenic Lower Urinary Tract Dysfunction: Dutch Translation and Validation of the Intermittent Catheterization Satisfaction Questionnaire, Intermittent Catheterization Acceptance Test, Intermittent Self Catheterization Questionnaire and Intermittent Catheterization Difficulty Questionnaire
    Herve, Francois
    Ragolle, Inge
    Amarenco, Gerard
    Viaene, Annick
    Guinet-Lacoste, Amandine
    Bonniaud, Veronique
    Everaert, Karel
    UROLOGIA INTERNATIONALIS, 2019, 102 (04) : 476 - 481
  • [8] Translation, reliability and validity of Japanese version the TeamSTEPPS® teamwork perceptions questionnaire
    Unoki, Takeshi
    Matsuishi, Yujiro
    Tsujimoto, Takahiro
    Yotsumoto, Ryuichi
    Yamada, Toru
    Komatsu, Yuka
    Kashiwakura, Daisaku
    Yamamoto, Norimasa
    NURSING OPEN, 2021, 8 (01): : 115 - 122
  • [9] Validity and reliability of Turkish version of Self Confidence Scale in Clean Intermittent Self Catheterization
    Culha, Yeliz
    Acaroglu, Rengin
    CUKUROVA MEDICAL JOURNAL, 2020, 45 (04): : 1690 - 1697
  • [10] The Japanese version of the questionnaire about the process of recovery: development and validity and reliability testing
    Akiko Kanehara
    Risa Kotake
    Yuki Miyamoto
    Yousuke Kumakura
    Kentaro Morita
    Tomoko Ishiura
    Kimiko Shimizu
    Yumiko Fujieda
    Shuntaro Ando
    Shinsuke Kondo
    Kiyoto Kasai
    BMC Psychiatry, 17