Corona Discharge Characteristics and Particle Losses in a Unipolar Corona-needle Charger Obtained through Numerical and Experimental Studies

被引:6
|
作者
Intra, Panich [1 ]
Yawootti, Artit [1 ]
Rattanadecho, Phadungsak [2 ]
机构
[1] Rajamangala Univ Technol Lanna, Res Unit Appl Elect Field Engn RUEE, Coll Integrated Sci & Technol, Chiang Mai, Thailand
[2] Thammasat Univ, Ctr Excellence Electromagnet Energy Utilizat Engn, Dept Mech Engn, Fac Engn, Bangkok, Thailand
关键词
Corona discharge; Particle charging; Aerosol charger; Numerical simulation; AEROSOL-PARTICLES; EFFICIENCIES; PERFORMANCE; IONIZER;
D O I
10.5370/JEET.2017.12.5.2021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the unipolar corona-needle charger was developed and its capabilities were both numerically and experimentally investigated. The experimental corona discharges and particle losses in the charger were obtained at different corona voltage, aerosol flow rate and particle diameter for positive and negative coronas. Inside the charger, the electric field and charge distribution and the transport behavior of the charged particle were predicted by a numerical simulation. The experimental results yielded the highest ion number concentrations of about 1.087 x 10(15) ions/m(3) for a positive corona voltage of about 3.2 kV, and 1.247 x 10(16) ions/m(3) for a negative corona voltage of about 2.9 kV, and the highest N(i)t product for positive and negative coronas was found to about 7.53 x 10(13) and 8.65 x 10(14) ions/m(3) s was occurred at the positive and negative corona voltages of about 3.2 and 2.9 kV, respectively, and the flow rate of 0.3 L/min. The highest diffusion loss was found to occur at particles with diameter of 30 nm to be about 62.50 and 19.33 % for the aerosol flow rate of 0.3 and 1.5 L/min, respectively, and the highest electrostatic loss was found to occur at particles with diameters of 75 and 50 nm to be about 86.29 and 72.92 % for positive and negative corona voltages of about 2.9 and 2.5 kV, respectively. The numerical results for the electric field distribution and the charged particles migration inside the charger were used to guide the description of the electric field and the behavior of charged particle trajectories to improve the design and refinement of a unipolar corona-needle charger that otherwise could not be seen from the experimental data.
引用
收藏
页码:2021 / 2030
页数:10
相关论文
共 11 条
  • [1] An experimental study of relative humidity and air flow effects on positive and negative corona discharges in a corona-needle charger
    Yawootti, Artit
    Intra, Panich
    Tippayawong, Nakorn
    Rattanadecho, Phadungsak
    JOURNAL OF ELECTROSTATICS, 2015, 77 : 116 - 122
  • [2] An Experimental Investigation of A Non-Mixing Type Corona-Needle Charger for Submicron Aerosol Particles
    Panich Intra
    Artit Yawootti
    Journal of Electrical Engineering & Technology, 2019, 14 : 363 - 370
  • [3] An Experimental Investigation of A Non-Mixing Type Corona-Needle Charger for Submicron Aerosol Particles
    Intra, Panich
    Yawootti, Artit
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2019, 14 (01) : 363 - 370
  • [4] Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger
    Intra, Panich
    Yawootti, Artit
    Vinitketkumnuen, Usanee
    Tippayawong, Nakorn
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (04) : 556 - 562
  • [5] Effect of needle cone angle and air flow rate on electrostatic discharge characteristics of a corona-needle ionizer
    Intra, Panich
    Tippayawong, Nakorn
    JOURNAL OF ELECTROSTATICS, 2010, 68 (03) : 254 - 260
  • [6] Experimental and Numerical Study on Discharge Characteristics of Carbon Brush Type-Corona Discharger
    Kim, Se Hyun
    Park, Gi Woong
    Choi, Ho Yeon
    Choi, Chang Yong
    Park, Seong Hyun
    Park, Yong Gap
    Lee, Dong Geun
    Ha, Man Yeong
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2021, 45 (12) : 681 - 689
  • [7] Experimental study of the characteristics of Trichel pulses in the needle-plane negative corona discharge in atmospheric air
    Dordizadeh, Peyman
    Adamiak, Kazimierz
    Castle, G. S. Peter
    JOURNAL OF ELECTROSTATICS, 2017, 88 : 49 - 54
  • [8] Unipolar model of negative corona discharge: Comparison of calculated and experimental I–V characteristics for the sphere–plane electrode system
    N. V. Mel’nikova
    A. V. Samusenko
    I. F. Safronova
    Technical Physics, 2017, 62 : 1135 - 1138
  • [9] DC negative corona discharge characteristics in air flowing transversely and longitudinally through a needle-plate electrode gap
    Berendt, Artur
    Budnarowska, Magdalena
    Mizeraczyk, Jerzy
    JOURNAL OF ELECTROSTATICS, 2018, 92 : 24 - 30
  • [10] Unipolar Model of Negative Corona Discharge: Comparison of Calculated and Experimental I-V Characteristics for the Sphere-Plane Electrode System
    Mel'nikova, N. V.
    Samusenko, A. V.
    Safronova, I. F.
    TECHNICAL PHYSICS, 2017, 62 (08) : 1135 - 1138