摘要
BACKGROUND AND OBJECTIVE: To investigate the short-term complication profile of the transconjunctival 20-gauge trocar-cannula (20g-TCV) system. PATIENTS AND METHODS: Patients who underwent primary 20g-TCV without history of prior vitrectomy were included. The primary outcome was incidence of short-term hypotony. Other data collected included visual acuity (VA), rate of sclerotomy suture placement, and intraoperative and postoperative complications. RESULTS: One hundred twenty-seven eyes of 120 patients were included. Postoperative complications included hypotony in 10.2% of eyes at the first postoperative day and 4.7% at week 1, all with spontaneous resolution. No cases of endophthalmitis were observed. Overall mean VA significantly improved from 20/375 preoperatively to 20/221 at month 3. CONCLUSION: Although the rate of short-term hypotony was relatively high, it was transient. This 20g-TCV system does not appear to be associated with other intraoperative or postoperative complications. The authors recommend a low threshold for sclerotomy suture placement if adopting this system. [Ophthalmic Surg Lasers Imaging 2011;42:278-283.]
引用
收藏
页码:278 / 283
页数:6
相关论文
共 50 条
  • [1] OUTCOMES OF 20-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY
    Spierer, Oriel
    Siminovsky, Zvia
    Loewenstein, Anat
    Barak, Adiel
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (09): : 1765 - 1771
  • [2] Sutureless transconjunctival 20-gauge vitrectomy
    Dassie-Ajdid, J.
    Mahieu, L.
    Mathis, V.
    Arne, J-L.
    Auriol, S.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (10): : 729 - 736
  • [3] Safety of 20-Gauge Transconjunctival Sutureless Vitrectomy
    Papaefthymiou, Ioannis
    Petropoulos, Ioannis K.
    Mangioris, George
    Mendrinos, Efstratios
    Pournaras, Constantin J.
    OPHTHALMOLOGICA, 2013, 230 (04) : 207 - 214
  • [4] 20-gauge transconjunctival pars plana vitrectomy
    Jorge, Rodrigo
    Gomes, Andre Vieira
    Siqueira, Rubens C.
    Costa, Rogerio A.
    Scott, Ingrid U.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2007, 38 (04) : 342 - 344
  • [5] Transconjunctival 20-Gauge Vitrectomy: A Pilot Study
    Aguni, Jonathan Seiji
    Meyer, Carsten H.
    Rodrigues, Eduardo B.
    OPHTHALMOLOGICA, 2009, 223 (01) : 12 - 16
  • [6] COMPARISON OF 20-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY WITH CONVENTIONAL VITRECTOMY
    Lee, Joo Eun
    Kim, Kyeong Hwan
    Kim, Ivana K.
    Jea, Seung Youn
    Kim, Wan Soo
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (09): : 1496 - 1504
  • [7] Learning curve of sutureless transconjunctival 20-gauge vitrectomy
    Simanjuntak, Gilbert W. S.
    Kartasasmita, Arief S.
    Georgalas, Ilias
    Gotzaridis, Eustratios V.
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1355 - 1359
  • [8] Modified 20-Gauge Transconjunctival Pars Plana Vitrectomy
    Stanescu-Segall, Dinu
    Sebag, Mikael
    Jackson, Timothy
    Elagouz, Mohammed
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (05): : 982 - 987
  • [9] Safety of transconjunctival sutureless 25-gauge vitrectomy in eyes with prior 20-Gauge vitrectomy
    Noffke, AS
    Sarrafizadeh, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [10] Three-port 20-gauge transconjunctival pars plana vitrectomy
    Gotzaridis, Eustratios V.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2007, 27 (03): : 382 - 384