Mesh electrode for peripheral nerve stimulation

被引:4
|
作者
Mobbs, RJ
Blum, P
Rossato, R
机构
[1] Calvary Hosp, Cairns, Qld, Australia
[2] Prince Wales Hosp, Inst Neurol Sci, Dept Neurosurg, Sydney, NSW, Australia
[3] Peripheral Nerve Res Fdn, Sydney, NSW, Australia
关键词
peripheral nerve; electrode; stimulator;
D O I
10.1016/S0967-5868(03)00090-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The implanted peripheral nerve stimulator has a role for pain relief in well-selected patients with pain in a peripheral nerve distribution. We describe an electrode to help simplify the surgical implantation of a peripheral nerve stimulator and also to reduce the possibility of electrode migration following implantation. Design details of the electrode are discussed, as are notes on surgical technique. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:476 / 477
页数:2
相关论文
共 50 条
  • [1] ELECTRODE POLARITY AND PERIPHERAL-NERVE STIMULATION
    BERGER, JJ
    GRAVENSTEIN, JS
    MUNSON, ES
    [J]. ANESTHESIOLOGY, 1982, 56 (05) : 402 - 404
  • [2] BIPOLAR ELECTRODE FOR PERIPHERAL-NERVE STIMULATION
    BARONE, FC
    WAYNER, MJ
    AGUILARBATURONI, HU
    GUEVARAAGUILAR, R
    [J]. BRAIN RESEARCH BULLETIN, 1979, 4 (03) : 421 - 422
  • [3] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION
    NAPLES, GG
    MORTIMER, JT
    SCHEINER, A
    SWEENEY, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) : 905 - 916
  • [4] SAFE SURFACE ELECTRODE FOR PERIPHERAL-NERVE STIMULATION
    KOPMAN, AF
    [J]. ANESTHESIOLOGY, 1976, 44 (04) : 343 - 345
  • [5] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION - COMMENT
    RACZ, GB
    HEAVNER, JE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) : 1140 - 1140
  • [6] Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
    Tyler, DJ
    Durand, DDM
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2002, 10 (04) : 294 - 303
  • [7] A SPIRAL NERVE CUFF ELECTRODE FOR PERIPHERAL-NERVE STIMULATION - REPLY
    NAPLES, GG
    MORTIMER, JT
    SCHEINER, A
    SWEENEY, JD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) : 1140 - 1141
  • [8] CHRONIC ELECTRODE FOR PERIPHERAL-NERVE STIMULATION - APPLICATION FOR VAGAL-STIMULATION
    SLAUGHTER, JS
    HAHN, WW
    [J]. PSYCHOPHYSIOLOGY, 1975, 12 (01) : 110 - 112
  • [9] Orderly recruitment order of peripheral nerve stimulation with electrode array
    Lertmanorat, Z
    Gustafson, KJ
    Durand, DM
    [J]. 2005 2ND INTERNATINOAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, 2005, : 529 - 532
  • [10] Stretchable, Fully Polymeric Electrode Arrays for Peripheral Nerve Stimulation
    Cuttaz, Estelle A.
    Chapman, Christopher A. R.
    Syed, Omaer
    Goding, Josef A.
    Green, Rylie A.
    [J]. ADVANCED SCIENCE, 2021, 8 (08)