Comparison between the ultraviolet emission from pulsed microhollow cathode discharges in xenon and argon

被引:14
|
作者
Petzenhauser, I [1 ]
Biborosch, LD
Ernst, U
Frank, K
Schoenbach, KH
机构
[1] Univ Erlangen Nurnberg, Dept Phys 1, FA, D-91058 Erlangen, Germany
[2] Al I Cuza Univ Iasi, Dept Plasma Phys, R-700365 Iasi, Romania
[3] Old Dominion Univ, Phys Elect Res Inst, Norfolk, VA 23529 USA
关键词
D O I
10.1063/1.1626020
中图分类号
O59 [应用物理学];
学科分类号
摘要
We measured the dynamic I-V characteristics and vacuum ultraviolet (VUV) emission lines of the second continuum in xenon (170 nm) and argon (130.5 nm) from pulsed microhollow cathode discharges (MHCD). For pulse lengths between 1 and 100 mus the dynamic I-V characteristics are similar in both inert gases. Only the time variation of the VUV emission line at 170 nm for xenon can be related to the dimer excited states. In argon the energy transfer between the Ar-2(*) dimers and the oxygen impurity atoms is responsible for a qualitatively different time behavior of the resonance line at 130.5 nm. Consequently, the relative VUV efficiency reveals an inverse dependence on the electrical pulse lengths for the MHCD in xenon and argon, respectively. (C) 2003 American Institute of Physics.
引用
下载
收藏
页码:4297 / 4299
页数:3
相关论文
共 50 条
  • [1] Xenon excimer emission from pulsed microhollow cathode discharges
    Moselhy, M
    Shi, W
    Stark, RH
    Schoenbach, KH
    APPLIED PHYSICS LETTERS, 2001, 79 (09) : 1240 - 1242
  • [2] Excimer emission from pulsed microhollow cathode discharges in xenon
    Lee, B. -J.
    Rahaman, H.
    Nam, S. H.
    Iberler, M.
    Jacoby, J.
    Frank, K.
    PHYSICS OF PLASMAS, 2013, 20 (12)
  • [3] Excimer Emission from Pulsed Tandem Microhollow Cathode Discharges in Xenon
    Lee, Byung-Joon
    Rahaman, Hasibur
    Nam, Sang Hoon
    Iberler, Marcus
    Teske, Christian
    Jacoby, Joachim
    Frank, Klaus
    APPLIED PHYSICS EXPRESS, 2012, 5 (05)
  • [4] Excimer emission from pulsed tandem microhollow cathode discharges in xenon
    Pohang Accelerator Laboratory, Pohang, Gyeongbuk 790-784, Korea, Republic of
    不详
    不详
    Appl. Phys. Express, 5
  • [5] Excimer emission from microhollow cathode argon discharges
    Moselhy, M
    Petzenhauser, I
    Frank, K
    Schoenbach, KH
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (23) : 2922 - 2927
  • [6] Excimer emission from thick microhollow cathode discharges in xenon
    Biborosch, LD
    Petzenhauser, I
    Popescu, S
    Lee, BJ
    Frank, K
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2005, 7 (05): : 2455 - 2458
  • [7] Excimer emission from microhollow cathode discharges
    El-Habachi, A.
    Moselhy, M.
    Stark, R.H.
    Schoenbach, K.H.
    IEEE International Conference on Plasma Science, 2000,
  • [8] Predicted properties of microhollow cathode discharges in xenon
    Boeuf, JP
    Pitchford, LC
    Schoenbach, KH
    APPLIED PHYSICS LETTERS, 2005, 86 (07) : 1 - 3
  • [9] Modeling of Mode Transition Behavior in Argon Microhollow Cathode Discharges
    Deconinck, Thomas
    Raja, Laxminarayan L.
    PLASMA PROCESSES AND POLYMERS, 2009, 6 (05) : 335 - 346
  • [10] Resonant energy transfer from argon dimers to atomic oxygen in microhollow cathode discharges
    Moselhy, M
    Stark, RH
    Schoenbach, KH
    Kogelschatz, U
    APPLIED PHYSICS LETTERS, 2001, 78 (07) : 880 - 882