Improved reproducibility of heart-to-mediastinum ratio by semi-automatic calculation algorithm in cardiac I-123 MIBG imaging

被引:0
|
作者
Okuda, Koichi [1 ]
Nakajima, Kenichi [2 ]
Hosoya, Tetsuo [3 ]
Ishikawa, Takehiro [3 ]
Matsuo, Shinro [2 ]
Taki, Junichi [2 ]
Kinuya, Seigo [2 ]
机构
[1] Kanazawa Univ, Grad Sch Med Sci, Kanazawa, Ishikawa, Japan
[2] Kanazawa Univ Hosp, Kanazawa, Ishikawa, Japan
[3] Fujifilm RI Pharma Co Ltd, Tokyo, Japan
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
2088
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Interobserver variability of heart-to-mediastinum ratio in I-123 MIBG sympathetic imaging
    Bulten, B. F.
    van der Palen, R. L. F.
    van Laarhoven, H. W. M.
    Kapusta, L.
    Mavinkurve-Groothuis, A. M. C.
    de Geus-Oei, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S508 - S508
  • [2] Letter to the Editor: Interobserver Variability of Heart-to-Mediastinum Ratio in I-123 MIBG Sympathetic Imaging
    Ben F. Bulten
    Roel L. F. van der Palen
    Hanneke W. M. van Laarhoven
    Livia Kapusta
    Annelies M. C. Mavinkurve-Groothuis
    Lioe-Fee de Geus-Oei
    Current Cardiology Reports, 2012, 14 : 389 - 390
  • [3] Letter to the Editor: Interobserver Variability of Heart-to-Mediastinum Ratio in I-123 MIBG Sympathetic Imaging
    Bulten, Ben F.
    van der Palen, Roel L. F.
    van Laarhoven, Hanneke W. M.
    Kapusta, Livia
    Mavinkurve-Groothuis, Annelies M. C.
    de Geus-Oei, Lioe-Fee
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (04) : 389 - 390
  • [4] Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging
    Koichi Okuda
    Kenichi Nakajima
    Tetsuo Hosoya
    Takehiro Ishikawa
    Takahiro Konishi
    Kosuke Matsubara
    Shinro Matsuo
    Seigo Kinuya
    Journal of Nuclear Cardiology, 2011, 18 : 82 - 89
  • [5] Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging
    Okuda, Koichi
    Nakajima, Kenichi
    Hosoya, Tetsuo
    Ishikawa, Takehiro
    Konishi, Takahiro
    Matsubara, Kosuke
    Matsuo, Shinro
    Kinuya, Seigo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (01) : 82 - 89
  • [6] Impact of prone-position acquisition of 123I-MIBG cardiac imaging on heart-to-mediastinum ratio
    Pellegrino, T.
    Piscopo, V.
    Boemio, A.
    Carotenuto, R.
    Russo, B.
    Pellegrino, S.
    De Matteis, G.
    Cuocolo, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S514 - S515
  • [7] Influence of ROI definition on the heart-to-mediastinum ratio in planar 123I-MIBG imaging
    Christiane Klene
    Christiane Jungen
    Koichi Okuda
    Yuske Kobayashi
    Annabelle Helberg
    Janos Mester
    Christian Meyer
    Kenichi Nakajima
    Journal of Nuclear Cardiology, 2018, 25 : 208 - 216
  • [8] Influence of ROI definition on the heart-to-mediastinum ratio in planar 123I-MIBG imaging
    Klene, Christiane
    Jungen, Christiane
    Okuda, Koichi
    Kobayashi, Yuske
    Helberg, Annabelle
    Mester, Janos
    Meyer, Christian
    Nakajima, Kenichi
    JOURNAL OF NUCLEAR CARDIOLOGY, 2018, 25 (01) : 208 - 216
  • [9] Planar 123I-MIBG heart-to-mediastinum ratio: the impact of a predefined ROI and collimator type on reproducibility
    Verschure, D. O.
    Bongers, V.
    Hagen, P. J.
    van Ofwegen-Hanekamp, C. E. E.
    Somsen, G. A.
    van Eck-Smit, B. L. F.
    Verberne, H. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S439 - S440
  • [10] The Influence of Cardiac ROIs Contour Definition at Heart-to-Mediastinum Ratio in 123I-MIBG Scintigraphy
    Sa Pinto, A.
    Vieira, T.
    Chaves, S.
    Alves, V.
    Faria, T.
    Oliveira, A.
    Fernandes, A.
    Perez, M.
    Pereira, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S364 - S365