A computational model for false lumen thrombosis in type B aortic dissection following thoracic endovascular repair

被引:48
|
作者
Menichini, Claudia [1 ]
Cheng, Zhuo [1 ]
Gibbs, Richard G. J. [2 ]
Xu, Xiao Yun [1 ]
机构
[1] Imperial Coll London, Dept Chem Engn, London SW7 2AZ, England
[2] Imperial Coll Healthcare NHS Trust, St Marys Hosp, Vasc Surg Unit, London W2 1NY, England
关键词
CFD; Aortic dissection; TEVAR; Thrombosis; False lumen; Hemodynamics; INITIAL FINDINGS; FLUID-DYNAMICS; HEMODYNAMICS; FLOW; SIMULATION; MANAGEMENT;
D O I
10.1016/j.jbiomech.2017.10.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Thoracic endovascular repair (TEVAR) has recently been established as the preferred treatment option for complicated type B dissection. This procedure involves covering the primary entry tear to stimulate aortic remodelling and promote false lumen thrombosis thereby restoring true lumen flow. However, complications associated with incomplete false lumen thrombosis, such as aortic dilatation and stent graft induced new entry tears, can arise after TEVAR. This study presents the application and validation of a recently developed mathematical model for patient-specific prediction of thrombus formation and growth under physiologically realistic flow conditions. The model predicts thrombosis through the evaluation of shear rates, fluid residence time and platelet distribution, based on convection-diffusion reaction transport equations. The model was applied to 3 type B aortic dissection patients: two TEVAR cases showing complete and incomplete false lumen thrombosis respectively, and one medically treated dissection with no signs of thrombosis. Predicted thrombus growth over time was validated against follow-up CT scans, showing good agreement with in vivo data in all cases with a maximum difference between predicted and measured false lumen reduction below 8%. Our results demonstrate that TEVAR-induced thrombus formation in type B aortic dissection can be predicted based on patient-specific anatomy and physiologically realistic boundary conditions. Our model can be used to identify anatomical or stent graft related factors that are associated with incomplete false lumen thrombosis following TEVAR, which may help clinicians develop personalised treatment plans for dissection patients in the future. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Predictor of false lumen thrombosis after thoracic endovascular aortic repair for type B dissection
    Li, Da
    Peng, Liqing
    Wang, Yi
    Zhao, Jichun
    Yuan, Ding
    Zheng, Tinghui
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 160 (02): : 360 - 367
  • [2] Fate and Consequences of the False Lumen After Thoracic Endovascular Aortic Repair in Type B Aortic Dissection
    Jubouri, Matti
    Patel, Ravi
    Tan, Sven Z. C. P.
    Al-Tawil, Mohammed
    Bashir, Mohamad
    Bailey, Damian M.
    Williams, Ian M.
    ANNALS OF VASCULAR SURGERY, 2023, 94 : 32 - 37
  • [3] Thoracic Endovascular Aortic Repair into the False Lumen in Chronic Aortic Dissection
    Kamman, Arnoud V.
    Williams, David M.
    Patel, Himanshu J.
    ANNALS OF VASCULAR SURGERY, 2017, 42 : 303.e11 - 303.e14
  • [4] Coil Embolization for Persistent Thoracic False Lumen of Type B Aortic Dissection after Thoracic Endovascular Aortic Repair
    Zhang, Hong
    Ge, Yang Yang
    Lu, Kai
    Cao, Long
    Liu, Peng
    Liu, Xiao Ping
    Wang, Li Jun
    Guo, Wei
    ANNALS OF VASCULAR SURGERY, 2019, 57 : 60 - 68
  • [5] Aortic False Lumen Thrombosis Induction by Embolotherapy (AFTER) Following Endovascular Repair of Aortic Dissection
    Hofferberth, Sophie C.
    Nixon, Ian K.
    Mossop, Peter J.
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 538 - 545
  • [6] Aortic False Lumen Thrombosis and Remodeling: The Paradigm for Endovascular Repair of Aortic Dissection
    San Norberto, Enrique M.
    Taylor, James
    Vaquero, Carlos
    JOURNAL OF ENDOVASCULAR THERAPY, 2012, 19 (04) : 546 - 548
  • [7] The characteristics of distal tears affect false lumen thrombosis rate after thoracic endovascular aortic repair for acute type B dissection
    Li, Da
    Yuan, Ding
    Peng, Liqing
    Zheng, Tinghui
    Fan, Yubo
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 33 (05) : 755 - 762
  • [8] Factors affecting distal false lumen enlargement after thoracic endovascular aortic repair for type B aortic dissection
    Tang, Qian-hui
    Chen, Jing
    Long, Zhen
    Wang, Yu-Lin
    Su, Xuan-an
    Qiu, Jian-ye
    Lin, Qiu-ning
    Zhang, Jiang-feng
    Qin, Xiao
    HELIYON, 2023, 9 (06)
  • [9] Promoting False-Lumen Thrombosis after Thoracic Endovascular Aneurysm Repair in Type B Aortic Dissection by Selectively Excluding False-Lumen Distal Entry Tears
    Wojtaszek, Mikolaj
    Wnuk, Emilia
    Maciag, Rafal
    Lamparski, Krzysztof
    Korzeniowski, Krzysztof
    Rowinski, Olgierd
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (02) : 168 - 175
  • [10] False Lumen Embolization to Treat Disseminated Intravascular Coagulation After Thoracic Endovascular Aortic Repair of Type B Aortic Dissection
    Mendes, Bernardo C.
    Oderich, Gustavo S.
    Erben, Young
    Reed, Nanette R.
    Pruthi, Rajiv K.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (06) : 938 - 941