Energy and Exergy Analyses of Regenerative Gas Turbine Air-Bottoming Combined Cycle: Optimum Performance

被引:6
|
作者
Khan, M. N. [1 ]
机构
[1] Majmaah Univ, Coll Engn, Dept Mech & Ind Engn, Majmaah 11952, Saudi Arabia
关键词
Energy; Exergy; Topping cycle; Air-bottoming cycle; Heat exchanger; Net output; Thermal efficiency; HELIOSTAT FIELD COLLECTOR; AMMONIA-WATER MIXTURE; WASTE HEAT-RECOVERY; POWER-PLANTS; THERMOECONOMIC EVALUATION; SYSTEM; OPTIMIZATION; INTEGRATION; EXCHANGER; STORAGE;
D O I
10.1007/s13369-020-04600-9
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The current paper presents a thermodynamic analysis of an air-bottoming cycle (ABC) operated by the exhaust gasses of a regenerative gas turbine cycle. The partial exhaust heat of a topping gas turbine cycle is utilized to heat the compressed air of the ABC by passing it through a heat exchanger (H.E.(2)), whereas remaining heat is used to heat the compressed air of the topping cycle before entering a combustion chamber by passing it through a heat exchanger (H.E.(1)). The effects of the turbine inlet temperature of the topping cycle (1000 K <= TIT <= 1500 K) and fraction of mass flow rate of the exhaust gas (0 <= x <= 1) on the net output, combined thermal efficiency, exergy destruction, exergy loss by exhaust gasses, and specific fuel consumption (SFC) are investigated parametrically for a particular value of the pressure ratio of the topping and bottoming cycles. At x=0, the net output and thermal efficiency of the combined cycle increase by 15.1% and 31.3%, respectively, whereas the SFC decreases by 13.1% and 15.5% at TIT=1000K} = 1000\;{\text{K}}$$\end{document} and TIT=1500K\ = 1500\;{\text{K}}$$\end{document}, respectively. The exergy destruction of the heat exchanger of the topping cycle increases, whereas that of the bottoming cycle decreases with an increase in x. Overall, in terms of the net output and thermal efficiency, a simple gas turbine cycle with an air-bottoming combined cycle performs better than a simple regenerative gas turbine cycle; however, in view of the exergy loss by exhaust gasses, a simple regenerative gas turbine cycle is better than the combined cycle.
引用
收藏
页码:5895 / 5905
页数:11
相关论文
共 50 条
  • [1] Energy and Exergy Analyses of Regenerative Gas Turbine Air-Bottoming Combined Cycle: Optimum Performance
    M. N. Khan
    Arabian Journal for Science and Engineering, 2020, 45 : 5895 - 5905
  • [2] Energetic and Exergetic Investigation of Regenerative Gas Turbine Air-Bottoming/Steam-Bottoming Combined Cycle
    Khan, Mohammad Nadeem
    MECHANIKA, 2021, 27 (03): : 251 - 258
  • [3] Performance analysis of gas turbine air-bottoming combined system
    Najjar, YSH
    Zaamout, MS
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (04) : 399 - 403
  • [4] Performance enhancement of regenerative gas turbine: air bottoming combined cycle using bypass valve and heat exchanger—energy and exergy analysis
    M. N. Khan
    Tawfeeq Abdullah Alkanhal
    Jihen Majdoubi
    Iskander Tlili
    Journal of Thermal Analysis and Calorimetry, 2021, 144 : 821 - 834
  • [5] Performance enhancement of regenerative gas turbine: air bottoming combined cycle using bypass valve and heat exchanger-energy and exergy analysis
    Khan, M. N.
    Alkanhal, Tawfeeq Abdullah
    Majdoubi, Jihen
    Tlili, Iskander
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 144 (03) : 821 - 834
  • [6] Exergy analysis of gas turbine with air bottoming cycle
    Ghazikhani, M.
    Khazaee, I.
    Abdekhodaie, E.
    ENERGY, 2014, 72 : 599 - 607
  • [7] Performance Analysis in Off-Design Condition of Gas Turbine Air-Bottoming Combined System
    Carcasci, Carlo
    Costanzi, Federico
    Pacifici, Beniamino
    ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 : 1037 - 1046
  • [8] Energy and exergy analysis and optimization of a gas turbine cycle coupled by a bottoming organic Rankine cycle
    Ahmadi, Behrooz
    Golneshan, Ali Akbar
    Arasteh, Hossein
    Karimipour, Arash
    Bach, Quang-Vu
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2020, 141 (01) : 495 - 510
  • [9] Energy and exergy analysis and optimization of a gas turbine cycle coupled by a bottoming organic Rankine cycle
    Behrooz Ahmadi
    Ali Akbar Golneshan
    Hossein Arasteh
    Arash Karimipour
    Quang-Vu Bach
    Journal of Thermal Analysis and Calorimetry, 2020, 141 : 495 - 510
  • [10] Air bottoming combined cycle performance analyses by the combined effect of variable parameters
    Khan, Mohammad N.
    Alzafiri, Dhare
    ARCHIVE OF MECHANICAL ENGINEERING, 2022, : 497 - 517