Multivariate Control Charts for Simultaneous Quality Monitoring of Isoniazid and Rifampicin in a Pharmaceutical Formulation Using a Portable Near Infrared Spectrometer

被引:12
|
作者
Costa, Fernanda S. L. [1 ]
Pedroza, Ricardo H. P. [1 ]
Porto, Dayanne L. [2 ]
Amorim, Marcelo V. P. [2 ]
Lima, Kassio M. G. [1 ]
机构
[1] Univ Fed Rio Grande do Norte, Programa Posgrad Quim, Inst Quim, Grp Pesquisa Quim Biol & Quimiometria, BR-59072970 Natal, RN, Brazil
[2] Univ Fed Rio Grande do Norte, NUPLAM, BR-59072970 Natal, RN, Brazil
关键词
multivariate control chart; principal component analysis; net analyte signal; process analyte technology; near infrared spectroscopy; NET ANALYTE SIGNAL; SPECTROSCOPY; CHEMOMETRICS; TABLETS; HOMOGENEITY;
D O I
10.5935/0103-5053.20140214
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
One of the keys to maintain high manufacturing quality improvement is the use of control charts. In this work, multivariate control charts based on significant principal component (PC) scores and net analytical signal (NAS) were developed to simultaneously monitor the quality of two active pharmaceutical ingredients (API) (isoniazid and rifampicin) in pharmaceutical formulation (laboratory samples and production samples) using a portable near infrared spectrometer. The limits for both multivariate charts were estimated using the quality specifications from the pharmaceutical formulation (+/- 5% of the nominal content of each API). The use of these multivariate control charts has provided a simple and powerful tool to evaluate the content of pharmaceutical formulations based on isoniazid and rifampicin capsules combined with near infrared spectroscopy. The procedure is rapid and adjustable for monitoring the production of the pharmaceutical preparations produced at UFRN/Brazil toward the process analytical technology (PAT) for the treatment of pulmonary tuberculosis.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 31 条
  • [1] A Multivariate Control Chart Approach for Calibration Transfer between NIR Spectrometers for Simultaneous Determination of Rifampicin and Isoniazid in Pharmaceutical Formulation
    Vasconcelos de Andrade, Eduardo Wagner
    Medeiros de Morais, Camilo de Lelis
    Lopes da Costa, Fernanda Saadna
    Gomes de Lima, Kassio Micheli
    CURRENT ANALYTICAL CHEMISTRY, 2018, 14 (05) : 488 - 494
  • [2] Multivariate control charts based on net analyte signal and near infrared spectroscopy for quality monitoring of Nimesulide in pharmaceutical formulations
    de Carvalho Rocha, Werickson Fortunato
    Rosa, Andre Luis
    Martins, Jose Antonio
    Poppi, Ronei Jesus
    JOURNAL OF MOLECULAR STRUCTURE, 2010, 982 (1-3) : 73 - 78
  • [3] Predicting sugarcane quality using a portable visible near infrared spectrometer and a benchtop near infrared spectrometer
    Aparatana, Kittipon
    Naomasa, Yumika
    Sano, Morito
    Watanabe, Kenta
    Mitsuoka, Muneshi
    Ueno, Masami
    Kawamitsu, Yoshinobu
    Taira, Eizo
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2023, 31 (01) : 14 - 23
  • [4] Application of near infrared spectroscopy and multivariate control charts for monitoring biodiesel blends
    de Oliveira, Ingrid Komorizono
    de Carvalho Rocha, Werickson F.
    Poppi, Ronei J.
    ANALYTICA CHIMICA ACTA, 2009, 642 (1-2) : 217 - 221
  • [5] Pharmaceutical Tablet Classification Using a Portable Spectrometer with Combinations of Visible and Near-Infrared Spectra
    Baik, Kyung-Jin
    Lee, Jae Hyung
    Kim, Youngsik
    Jang, Byung-Jun
    2017 NINTH INTERNATIONAL CONFERENCE ON UBIQUITOUS AND FUTURE NETWORKS (ICUFN 2017), 2017, : 1011 - 1014
  • [6] Dissolution testing of isoniazid, rifampicin, pyrazinamide and ethambutol tablets using near-infrared spectroscopy (NIRS) and multivariate calibration
    de Oliveira Neves, Ana Carolina
    Soares, Gustavo Mesquita
    de Morais, Stephanie Cavalcante
    Lopes da Costa, Fernanda Saadna
    Porto, Dayanne Lopes
    Gomes de Lima, Kassio Michell
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 115 - 119
  • [7] Quality control of pharmaceutical aspirin powder by near-infrared reflectance spectra and multivariate analysis
    Ren, YL
    Zhang, ZY
    Ren, YQ
    Li, W
    Liu, SD
    SPECTROSCOPY LETTERS, 1997, 30 (08) : 1699 - 1711
  • [8] Monitoring the quality of oils for biodiesel production using multivariate near infrared spectroscopy models
    Baptista, Patricia
    Felizardo, Pedro
    Menezes, Jose C.
    Correia, M. Joana Neiva
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2008, 16 (05) : 445 - 454
  • [9] Portable near-infrared instruments: Application for quality control of polymorphs in pharmaceutical raw materials and calibration transfer
    da Silva, Vitor Hugo
    da Silva, Janson Jose
    Pereira, Claudete Fernandes
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 134 : 287 - 294
  • [10] Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts
    Skibsted, ETS
    Boelens, HFM
    Westerhuis, JA
    Witte, DT
    Smilde, AK
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (01) : 26 - 35